• 제목/요약/키워드: Equivalent k

검색결과 7,561건 처리시간 0.035초

전자기 과도현상 해석을 위한 S 영역 등가시스템 PART 2 :주파수 의존 교류 시스템 등가 (S-Domain Equivalent System for Electromagnetic Transient Studies PART 2 : Frequency Dependent Network Equivalent)

  • 왕용필;이현정;정형환;안병철;김해재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.283-285
    • /
    • 2004
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. This paper presents the formulation for developing 1 & 2 port Frequency Dependent Network Equivalent (FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 & 2 Port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port (FDNE) developed with Norton Equivalent network.

  • PDF

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 1: derivation

  • Kim, Kang Su;Choi, Seung-Ho;Ju, Hyunjin;Lee, Deuck Hang;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.719-733
    • /
    • 2014
  • The equivalent frame method (EFM) is widely used for the design of two-way reinforced concrete slab structures, and current design codes of practice permit the application of the EFM in analyzing the flat plate slab structures under gravity and lateral loads. The EFM was, however, originally developed for the flat plate structures subjected to gravity load, which is not suitable for lateral loading case. Therefore, this study, the first part of series research paper, proposed the structural analysis method for the flat plate slab structures under the combined gravity and lateral loads, which is named as the unified equivalent frame method (UEFM). In the proposed method, some portion of rotation induced in the torsional member is distributed to the flexibility of the equivalent columns, and the remaining portion is contributed to that of the equivalent slabs. In the consecutive companion paper, the proposed UEFM is verified by comparing with test results of multi-span flat plate structures. Also, a simplified nonlinear push-over analysis method is proposed, and verified by comparing to test results.

Dynamic equivalent model of a SMART control rod drive mechanism for a seismic analysis

  • Ahn, Kwanghyun;Lee, Jae-Seon
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1834-1846
    • /
    • 2020
  • The SMART (System-integrated Modular Advanced ReacTor) is an integral-type small modular reactor developed by KAERI (Korea Atomic Energy Research Institute). This paper discusses the development of a dynamic equivalent model of the SMART control rod drive mechanism that can be efficiently utilized for complicated analysis during the design of the SMART. A semi-empirical approach is used to develop the equivalent model; that is, the equivalent model is defined analytically and verified empirically. Two types of tests, dynamic characteristics tests and seismic loading tests, are conducted for the development and verification of the dynamic equivalent model, respectively. Acceleration response spectra from the seismic analysis based on the developed equivalent model show good agreement with those from the seismic loading tests.

두 개의 공진점을 갖는 광대역 초음파 전기음향 변환기의 등가회로변수 추정 (Estimation of Equivalent Circuit Parameters for Dual Resonance Electroacoustic Transducer Using Iterative Levy Method)

  • 임준석;편용국
    • 전자공학회논문지 IE
    • /
    • 제49권2호
    • /
    • pp.18-23
    • /
    • 2012
  • 변환기의 해석 및 정합설계에 있어서 측정되어진 데이터로 부터 그 변환기의 전기, 기계, 음향적인 특성변수를 추출하는 기술의 확보는 필수적이다. 이와 관련한 기존의 방법은 단일 공진을 갖는 변환기를 위한 것이 많았다. 본 연구에서는 두 개의 공진점을 갖는 광대역 전기음향변환기의 정확한 특성변수 추출을 위하여 Levy Method 반복적으로 사용하여 그 오차를 최소화하는 알고리듬을 개발하였다.

Realistic Equivalent Load Methods in Prestressed Concrete Structures

  • Oh, Byung-Hwan;Jeon, Se-Jin
    • KCI Concrete Journal
    • /
    • 제13권1호
    • /
    • pp.11-17
    • /
    • 2001
  • The purpose of this state-of-the-art paper is to explore several important methods thor obtaining the equivalent loads in prestressed concrete structures. and to clarify the theoretical basis and implied assumptions of each method. The method devised in this stuffily include the use of curvature of tendon, characteristics of primary moment, self-equilibrium condition and linear segments approximation of tendon. It is shown that equivalent loading system it not uniquely determined depending on the approach adopted to calculate the equivalent loads. Self-equilibrium conditions of the equivalent loading system are carefully discussed. Numerical examples are presented to show the differences among the methods arid results of the approximations in each method explicitly.

  • PDF

Equivalent static wind loads for stability design of large span roof structures

  • Gu, Ming;Huang, Youqin
    • Wind and Structures
    • /
    • 제20권1호
    • /
    • pp.95-115
    • /
    • 2015
  • Wind effects on roofs are usually considered by equivalent static wind loads based on the equivalence of displacement or internal force for structural design. However, for large-span spatial structures that are prone to dynamic instability under strong winds, such equivalent static wind loads may be inapplicable. The dynamic stability of spatial structures under unsteady wind forces is therefore studied in this paper. A new concept and its corresponding method for dynamic instability-aimed equivalent static wind loads are proposed for structural engineers. The method is applied in the dynamic stability design of an actual double-layer cylindrical reticulated shell under wind actions. An experimental-numerical method is adopted to study the dynamic stability of the shell and the dynamic instability originating from critical wind velocity. The dynamic instability-aimed equivalent static wind loads of the shell are obtained.

Proposed Equivalent Circuit and Parameter Identification Method for Electro-Magnetic Resonance Based Wireless Power Transfer

  • Kawamura, Atsuo;Kim, Tae-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.799-807
    • /
    • 2013
  • The proper equivalent circuit is newly presented for electro-magnetic resonance based wireless power transfer. Based on the proposed equivalent circuit of open-ended helical antennas, the parameter identification of helical antennas can be well derived for highly efficient wireless power transfer. The well-established equivalent circuit in high frequency ranges is developed for analyzing a resonance enhanced-electromagnetic coupling helical antennas and the unknown parameters for helical antennas are identified by experiments. The effectiveness based on the proposed equivalent circuit is verified through experiments.

고분자 전해질 FC 평가용 등가회로 검토 (Investigation of Equivalent Circuit for PEMFC Assessment)

  • 명광재
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.897-902
    • /
    • 2011
  • PEMFC 의 내부에서 발생하는 화학반응은 계면의 물리적 조건 및 물성에 지배되고 그 거동은 임피던스로 표현된다. 일반적으로 임피던스 특성은 전기적 등가회로로 표현이 가능하기 때문에 PEMFC의 임피던스 계측 결과를 등가회로를 이용하여 해석함으로써 간단히 성능 진단을 할 수 있을 것이다. 본 연구에서는 이러한 등가회로를 이용하여 고분자 전해질 연료전지의 특성평가에 관한 기초연구를 수행하였다. 교류 임피던스 계측 값과 다양한 등가회로(단순 등가회로, CPE 를 고려한 등가회로, 2 개의 시정수를 고려한 등가회로, 2 개의 CPE 를 고려한 등가회로)를 이용하여 특성평가를 수행하였다. 그 결과 등가회로를 이용한 PEMFC 의 특성평가가 가능하고, 2 개의 CPE 를 고려한 등가회로가 가장 정도가 높음을 확인하였다.

On the limit cycles of aeroelastic systems with quadratic nonlinearities

  • Chen, Y.M.;Liu, J.K.
    • Structural Engineering and Mechanics
    • /
    • 제30권1호
    • /
    • pp.67-76
    • /
    • 2008
  • Limit cycle oscillations of a two-dimensional airfoil with quadratic and cubic pitching nonlinearities are investigated. The equivalent stiffness of the pitching stiffness is obtained by combining the linearization and harmonic balance method. With the equivalent stiffness, the equivalent linearization method for nonlinear flutter analysis is generalized to address aeroelastic system with quadratic nonlinearity. Numerical example shows that good approximation of the limit cycle can be obtained by the generalized method. Furthermore, the proposed method is capable of revealing the unsymmetry of the limit cycle; however the ordinary equivalent linearization method fails to do so.

유한요소법과 등가회로법의 결합을 이용한 인버터 구동 3상 농형 유도전동기의 과도 특성 해석 (Transient Analysis of Inverter-fed Three Phase Squirrel Cage induction Motor Using A Combined Method of Finite Element Method and Equivalent Circuit)

  • 조용;권병일;김재우;김병택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.805-807
    • /
    • 2002
  • In this paper, a method for an accurate and fast transient analysis, which employs a single slot model for the rotor, is presented. The equivalent circuit parameters are extracted from a combined method of F. E. M and equivalent circuit on 1 slot rotor boundary condition. Two kinds of circuit parameters for each slip are applied to equivalent circuit controlled by variable-voltage variable- frequency. One is the constant parameters at rated speed, and the other is the parameters varying in accordance with slip-frequency. The computer characteristics of the suggested method for four-pole 1.5KW induction motor are compared with those of Equivalent circuit for the transient analysis.

  • PDF