• Title/Summary/Keyword: Equivalent k

검색결과 7,561건 처리시간 0.029초

콜라겐과 무세포진피를 이용한 혼합형 인공피부 개발 및 쥐 모델에서 창상치료 적용 (Application of a Composite Skin Equivalent using Collagen and Acellular Dermal Matrix as the Scaffold in a Mouse Model of Full-thickness Wound)

  • 이동혁;윤진철;이정희;김인섭
    • KSBB Journal
    • /
    • 제29권1호
    • /
    • pp.42-49
    • /
    • 2014
  • The aim of this study was to develop a composite human skin equivalent for wound healing. Collagen type1 and acellular dermal matrix powder were utilized as the scaffold with dermal fibroblasts and keratinocytes for the development of a composite human skin equivalent. Fibroblast maintained the volume of composite skin equivalent and also induced keratinocytes to attach and proliferate on the surface of composite skin equivalent. The composite human skin equivalent had a structure and curvature similar to those of real skin. Balb-C nu/nu mice were used for the evaluation of full-thickness wound healing effect of the composite human skin equivalent. Graft of composite skin equivalent on full-thickness wound promoted re-epithelialization and granulation tissue formation at 9 days. Given the average wound-healing time (14 days), the wound in the developed composite skin equivalent healed quickly. The overall results indicated that this three-dimensional composite human skin equivalent can be used to effectively enhance wound healing.

Determination of equivalent blasting load considering millisecond delay effect

  • Song, Zhan-Ping;Li, Shi-Hao;Wang, Jun-Bao;Sun, Zhi-Yuan;Liu, Jing;Chang, Yu-Zhen
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.745-754
    • /
    • 2018
  • In the analysis of the effects of rock tunnel blasting vibration on adjacent existing buildings, the model of simplified equivalent load produces higher calculation result of vibration, due to the lack of consideration of the millisecond delay effect. This paper, based on the static force equivalence principle of blasting load, proposes a new determination method of equivalent load of blasting vibration. The proposed method, based on the elastic-static force equivalence principle of stress wave, equals the blasting loads of several single blastholes in the same section of millisecond blasting to the triangle blasting load curve of the exploded equivalent elastic boundary surface. According to the attenuation law of stress wave, the attenuated equivalent triangle blasting load curve of the equivalent elastic boundary is applied on the tunnel excavation contour surface, obtaining the final applied equivalent load. Taking the millisecond delay time of different sections into account, the time-history curve of equivalent load of the whole section applied on the tunnel excavation contour surface can be obtained. Based on Sailing Tunnel with small spacing on Sanmenxia-Xichuan Expressway, an analysis on the blasting vibration response of the later and early stages of the tunnel construction is carried out through numerical simulation using the proposed equivalent load model considering millisecond delay effect and the simplified equivalent triangle load curve model respectively. The analysis of the numerical results comparing with the field monitoring ones shows that the calculation results obtained from the proposed equivalent load model are closer to the measured ones and more feasible.

디지털 영상 시스템을 이용한 알루미늄 당량화상에 의한 골량 측정에 관한 연구 (A study on assessment of bone mass from aluminum-equivalent image by digital imaging system)

  • 김진수;최의환;김재덕
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.87-97
    • /
    • 1997
  • The purpose of this study was to evaluate the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxyapatite block and hydroxyapatite mass. The results of this study were as follow; 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated(r²=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference(P<0.05) between them 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r²=0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different(P<0.05).

  • PDF

펄스파워용 고전압 커패시터 등가직렬 임피던스 측정에 관한 연구 (Study on Measurement Technology for Equivalent Series Impedance of High-voltage Pulsed Power Capacitors)

  • 이병윤;이병하
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.937-942
    • /
    • 2013
  • Equivalent series impedance of high-voltage pulsed power capacitor is one of the important electrical characteristics both for users and for capacitor manufacturers because it may have serious effects on the performance of pulse forming circuits. In this paper, definition of equivalent series impedance and factors which generate equivalent series impedance are reviewed. Theoretical analysis for the calculation of equivalent series impedance based on differential measurement method is described and calculation program has been developed. In order to acquire data which are necessary to calculate equivalent series impedance from discharging current waveform, charging-dischargig controller has been manufactured. Measurement results of equivalent series impedance for high voltage pulsed power capacitor have been given.

Equivalent stiffness method for nonlinear analysis of stay cables

  • Xia, G.Y.;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.661-667
    • /
    • 2011
  • In the famous equivalent elasticity modulus method proposed by Ernst for the geometrical nonlinear analysis of stay cables, the cable shape was assumed as a parabolic curve, and only a part of the gravity load normal to the chord was taken into account with the other part of gravity load parallel to the chord being ignored. Using the actual catenary curve and considering the entire gravity load of stay cables, the present study has derived the equivalent stiffness method to analyze the sag effect of stay cables in cable-stayed bridges. The derived equivalent stiffness can be degenerated into Ernst's equivalent elasticity modulus method with some approximations. Therefore, the Ernst's method is a special and approximate formulation of the present method. The derived equivalent stiffness provides a theoretical explanation for the famous Ernst's formula.

Equivalent period and damping of SDOF systems for spectral response of the Japanese highway bridges code

  • Sanchez-Flores, Fernando;Igarashi, Akira
    • Earthquakes and Structures
    • /
    • 제2권4호
    • /
    • pp.377-396
    • /
    • 2011
  • In seismic design and structural assessment using the displacement-based approach, real structures are simplified into equivalent single-degree-of-freedom systems with equivalent properties, namely period and damping. In this work, equations for the optimal pair of equivalent properties are derived using statistical procedures on equivalent linearization and defined in terms of the ductility ratio and initial period of vibration. The modified Clough hysteretic model and 30 artificial accelerograms, compatible with the acceleration spectra for firm and soft soils, defined by the Japanese Design Specifications for Highway Bridges are used in the analysis. The results obtained with the proposed equations are verified and their limitations are discussed.

소나 송신기의 정합회로 설계를 위한 수중 음향 압전 트랜스듀서의 등가회로 파라미터 추정 (Estimation of Equivalent Circuit Parameters of Underwater Acoustic Piezoelectric Transducer for Matching Network Design of Sonar Transmitter)

  • 이정민;이병화;백광렬
    • 한국군사과학기술학회지
    • /
    • 제12권3호
    • /
    • pp.282-289
    • /
    • 2009
  • This paper presents an estimation technique of the equivalent circuit parameters for an underwater acoustic piezoelectric transducer from the measured impedance. Estimated equivalent circuit can be used for the design of the impedance matching network of the sonar transmitter. A fitness function is proposed to minimize the error between the calculated impedance of the equivalent circuit and the measured impedance of the transducer. The equivalent circuit parameters are estimated by using the fitness function and the PSO(Particle Swarm Optimization) algorithm. The effectiveness of the proposed method is verified by the applications to a sandwich-type transducer and a dummy load. In addition, the impedance matching network is also designed by using the estimated equivalent circuit model.

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

  • Moon, Byeong-Yeon;Kim, Sang-Yoeb;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • 제17권2호
    • /
    • pp.219-223
    • /
    • 2013
  • The purpose of this study was to determine the relationship between the spherical equivalent visual acuity (VA) and uncorrected astigmatism. On 108 emmetropic eyes, the spherical equivalent VA was measured for cross cylindrical lens (CC lens)-induced astigmatic eyes and the VA-astigmatism relation determined. On 158 astigmatic eyes, the spherical equivalent VA and corrected astigmatism were measured and the measured values were compared with the calculated values from the VA-astigmatism relation by correlation coefficient analysis. Subsequent to that, the relationship between spherical equivalent VA and uncorrected astigmatism was made. The relationship was fitted for an exponential equation. Correlation coefficient between calculated values by equation and measured values for astigmatic eyes was 0.991 (p<0.01). The relationship between the spherical equivalent VA and the uncorrected astigmatism was decided as follows (spherical equivalent VA / uncorrected astigmatism): 1.0 / 0.25 D, 0.9 / 0.50 D, 0.8 / 0.75 D, 0.7 / 1.00 D, 0.6 / 1.25 D, 0.5 / 1.50 D, 0.4 / 2.00 D, 0.3 / 2.50 D, 0.2 / 3.00 D, 0.1 / 4.00 D, and 0.05 / 4.75 D. In conclusion, the relationship table devised from this study is a useful reference for predicting uncorrected astigmatism by measurement of decimal VA in spherical equivalent.

Rosen형 적층 압전변압기의 등가회로 모델링 (Equivalent Circuit Modeling of Rosen-type Multilayer Piezoelectric Transformer)

  • 신훈범;이용국;유영한;안형근;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1099-1105
    • /
    • 2006
  • In this paper, the equivalent circuit model of a Rosen-type multilayer piezoelectric transformer(MPT) has been proposed based on the Mason's equivalent circuit model and the principle of single layer piezoelectric plate. From the piezoelectric direct and converse effects, the symbolic expressions between the electric inputs and outputs of the MPT have been derived from the equivalent circuit model. A simplified equivalent circuit model of the MPT whose driving part has a single input form has been proposed. The symbolic expressions of the driving part have been derived from the simplified equivalent circuit model and the model was compared with the multi-input equivalent circuit model through the simulation. In the comparisons between the simulation results and the experimental data, output voltage is 630 Vp-p in case of 11-layered MPT and 670 Vp-p for 13-layered MPT over the experiment range. As the load resistance increases, output voltage increases and saturates over $300k{\Omega}$ and the resonant frequency changes from 102 kHz to 103 kHz. The simulation and the experimental results agree well over different load resistances and frequencies.

Equivalent Circuit Parameters of S-band 1.5 Cell RF Gun Cavity

  • Kim, Ki-Young;Kang, Heung-Sik;Tae, Heung-Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제4권1호
    • /
    • pp.30-36
    • /
    • 2004
  • We determined equivalent circuit parameters of a 1.5 cell S-band RF gun cavity from the resonant characteristics of its decoupled cavities(half cell and full cell) using the code SUPERFISH. Equivalent circuit parameters of the 1.5 cell RF gun cavity resonated in the 0-mode were obtained easily from the circuit parameters of each decoupled cavities. In order to obtain equivalent circuit parameters for the $\pi$ -mode cavity, we calculated the differences of the resonant frequencies and the equivalent resistances between the 0- and $\pi$ -modes with slight variations of the radius and thickness of the coupling iris. From those differences, we obtained R/Q value and equivalent resistance of the $\pi$ -mode, which are directly related to the equivalent circuit parameters of the coupled cavity. Using calculated R/Q value, we can express equivalent inductance, capacitance and resistances of the RF gun cavity resonated in the $\pi$ -mode, which can be useful for analyzing coupled cavities in a steady state.