• Title/Summary/Keyword: Equivalent energy method

Search Result 476, Processing Time 0.026 seconds

3D-based equivalent model of SMART control rod drive mechanism using dynamic condensation method

  • Ahn, Kwanghyun;Lee, Kang-Heon;Lee, Jae-Seon;Chang, Seongmin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1109-1114
    • /
    • 2022
  • The SMART (System-integrated Modular Advanced ReacTor) is an integral-type small modular reactor developed by KAERI (Korea Atomic Energy Research Institute). This paper discusses the feasibility and applicability of a 3D-based equivalent model using dynamic condensation method for seismic analysis of a SMART control rod drive mechanism. The equivalent model is utilized for complicated seismic analysis during the design of the SMART. While the 1D-based beam-mass equivalent model is widely used in the nuclear industry for its calculation efficiency, the 3D-based equivalent model is suggested for the seismic analysis of SMART to enhance the analysis accuracy of the 1D-based equivalent model while maintaining its analysis efficiency. To verify the suggested model, acceleration response spectra from seismic analysis based on the 3D-based equivalent model are compared to those from the 1D-based beam-mass equivalent model and experiments. The accuracy and efficiency of the dynamic condensation method are investigated by comparison to analysis results based on the conventional modeling methodology used for seismic analysis.

Estimation of Plastic Energy Dissipation Amount of Multi-bent Spatial structure by Equivalent Linear Analysis

  • Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.131-136
    • /
    • 2006
  • It is important to evaluate energy absorption capacity of frames required during a design earthquake. An inelastic computer analysis based on mathematical modelling of energy absorbing frames and elements makes it possible to evaluate required energy absorption capacity. But such an analysis sometimes consumes much computation time particularly in case of complicated structural system. This paper presents a proposal to predict energy absorption of multi-bent steel frames by simple equivalent linear method.

  • PDF

Analysis of Vibration-powered Piezoelectric Energy Harvesters by Using Equivalent Circuit Models (등가 회로 모델을 이용한 압전 진동 에너지 수확 장치의 해석)

  • Kim, Jae-Eun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.397-404
    • /
    • 2010
  • The use of equivalent circuit models of piezoelectric energy harvesters is inevitable when power circuitry including rectifying and smoothing circuit elements is connected to them for evaluating DC electrical outputs. This is because it is difficult to incorporate the electro-mechanical coupling resulting from the additional circuitry into the conventional finite element analysis. Motivated by this observation, we propose a method to accurately extract the equivalent circuit parameters by using commercially available FEM software such as ANSYS which provides three-dimensional AC piezoelectric analysis. Then the equivalent circuit can be analyzed by circuit simulators such as $SimPowerSystems^{TM}$ of MATLAB. While the previous works have estimated the circuit parameters by experimental measurements or by analytical solutions developed only for limited geometries and boundary conditions, the proposed method has no such limitation because piezoelectric energy harvesters of any shapes and boundary conditions can be treated in FEM software. For the verification of the proposed method, multi-modal AC electrical power output by using a corresponding equivalent circuit is compared with that by ANSYS. The proposed method is then shown to be very useful in the subsequent evaluation of DC electrical output which is obtained by attaching a bridge diode and a storage capacitor to a piezoelectric energy harvester.

Estimation of Beam Mode Frequencies of Co-axial Cylinders Immersed in Fluid by Equivalent Mass Approach

  • Kim, Tae-Wan;Park, Suhn;Park, Keun-Bae
    • Nuclear Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.1-13
    • /
    • 2003
  • In this study, an effective method to estimate the fundamental frequencies of co-axial cylinders immersed in fluid is proposed. The proposed method makes use of the equivalent mass or density that is derived from the added mass matrix caused by the fluid-structure interaction (FSI) phenomenon. The equivalent mass is defined from the added mass matrix based on a 2-D potential flow theory. The theory on two co-axial cylinders extended to the case of three cylinders. To prove the validity of the proposed method, the eigenvalue analyses upon coaxial cylinders coupled with fluid gaps are peformed using the equivalent mass. The analyses results upon various fluid gap is conditions reveal that the present method could provide accurate frequencies and be suitable for expecting the fundamental frequencies of fluid coupled cylinders in beam mode vibration.

Comparison of Energy Demand in Multi-Story Structures and Equivalent SDOF Systems (다층 구조물과 등가 단자유도계의 에너지 요구량 비교)

  • 최현훈;원영섭;김진구
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.19-26
    • /
    • 2003
  • In energy-based design, the structures are generally transformed into equivalent SDOF systems to obtain the input and the dissipated energy. In this study the energy demands in multi-story structures were compared with that of equivalent single degree of freedom systems to validate the transformation method. Three-, eight-, and twenty-story steel moment-resisting frames and buckling restrained braced frames are compared with those of equivalent single degree of freedom systems. Sixty earthquake ground motions recorded in different soil conditions were used to compute the input and hysteretic energy demands in model structures. According to the analysis results, in 3 and 8-story structures the hysteretic energy demands computed in the equivalent SDOF structures are compatible with those computed in the original MDOF structures, while in the 20-story structures the transformed equivalent structures underestimated the hysteretic energy demands.

  • PDF

Linearization of Nonlinear Random Vibration Beam by Equivalent Energy Method (비선형 불규칙 진동 보의 등가에너지법에 의한 선형화)

  • Lee, Sin-Young;Cai, G.Q.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.71-76
    • /
    • 2008
  • Nonlinear dynamic system under random excitation was analyzed by using stochastic method. A linearization method was used in order to linearize non-linear structural characteristics but the parametric excitation was used as it was given. An equivalent energy method which equalizes the expectation value of energy of the original nonlinear system and that of quasi-linearized system was proposed. Ito's differential rule was applied to obtain steady state moments. Quasi-linearization coefficients can be obtained the iterative calculation of linearization scheme and steady state moments. Monte Carlo simulation was used to verify the results of the proposed method. Nonlinear vibration of a slender beam was analyzed in this research. The analysis results were compared with Monte Carlo simulation result and showed good agreement. As the spectral density of the given excitation increased, the analysis results showed the better agreement with Monte Carlo simulation.

Static Equivalent Model of Inverter-based Distributed Energy Resource for Fault Analysis of Power Distribution Grid

  • Kim, Dong-Eok;Cho, Namhun;Yang, Seung-Kwon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.569-575
    • /
    • 2016
  • In this paper, we propose a method to develop a static equivalent model of an inverter-based distributed energy resource (DER), where the model is used for a steady-state fault analysis of a power grid. First, we introduce the characteristics of an inverter-based DER as well as its general configuration. Then, we derive the equivalent model of the DER on the basis of the characteristics. Last, the performance of the proposed method is proven by the results of computer simulations.

Study on the Calculation of the Blast Pressure of Vapor Cloud Explosions by Analyzing Plant Explosion Cases (플랜트 폭발 사례 분석을 통한 증기운 폭발의 폭압 산정법 연구)

  • Lee, Seung-Hoon;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • Vapor cloud explosions show different characteristics from that caused by ordinary TNT explosives and their loading effect is similar to pressure waves. Typical methods used for blast pressure calculations are the TNT-equivalent method and multi-energy method. The TNT-equivalent method is based on shock waves, similar to a detonation phenomenon, and multi-energy method is based on pressure waves, similar to a deflagration phenomenon. This study was conducted to derive an appropriate blast pressure by applying various plant explosion cases. SDOF analysis and nonlinear dynamic analysis were performed to compare the degree of deformation and damage of the selected structural members for the explosion cases. The results indicated that the multi-energy method was more exact than the TNT-equivalent method in predicting the blast pressure of vapor cloud explosions. The blast pressure of vapor cloud explosion in plants can be more accurately calculated by assuming the charge strength of multi-energy method as 7 or 8.

Role of London Energy in Determining the C-Dimensions of Phyllosilicates (층상 규산염광물 C-축 결정에 있어서의 런던에너지 역할)

  • 유재영
    • Journal of the Mineralogical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.89-97
    • /
    • 1990
  • To examine how London energy controls the c-dimensions of phyllosilicates, London energy, as well as Coulomb and Pauli repulstion energy was calculated as a function of d(001) for 1M and d(002) for 2M 1 phyllosilicates. London and Pauli repulstion energy calcualtion use a direct interaction calculation method and Coulomb energy calculation adopts Fourier synthesis method. The energy calculations show that Coulmb and Pauli repulsion energy dominantly control the c-dimensions of phyllosilicates having the interlayer cationss, i.e., the layer charges. On the other hand, if phyllosilicates have no interlayer cations, London energy is solely responsible for holding the layers and maintain the c-dimensions. The significance of London energy in determining the c-dimensions of phyllosislicates de-creases as the layer charge increases. When the layer charge is lower than one equivalent on the basis of Oη(OH)2 formula, London energy plays an important role in determing the c-dimensions. however, if the layer charge is higher than one equivalent, London energy becomes insignifi-cant in determining the c-dimension.

  • PDF

A Review of TNT Equivalent Method for Evaluating Explosion Energy due to Gas Explosion (가스폭발에 따른 폭발에너지를 평가하기 위한 TNT 등가량 환산방법에 대한 고찰)

  • Kwon, Sangki;Park, Jung-Chan
    • Explosives and Blasting
    • /
    • v.33 no.3
    • /
    • pp.1-13
    • /
    • 2015
  • Accidents related to gas explosion are frequently happened in foreign countries and in Korea. For the evaluation and the analysis of gas explosions, TNT equivalent methods are used. In this study, the influence of the selection of chemical equation in TNT explosion and the selection of enthalpy of the products on the explosion energy, detonation pressure, velocity of detonation, and temperature was calculated. Depending on the chemical equations, the maximum detonation pressure can be 2 times higher than the minimum. As an example for applying TNT equivalent method, an explosion of methane gas in a confined volume was assumed. With the TNT equivalent, it was possible to predict the variation of peak overpressure and impulse with the distance from the explosion location.