• 제목/요약/키워드: Equivalent current sampling

검색결과 16건 처리시간 0.026초

The Effect of Transformer Leakage Inductance on the Steady State Performance of Push-pull based Converter with Continuous Current

  • Chen, Qian;Zheng, Trillion Q.;Li, Yan;Shao, Tiancong
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.349-361
    • /
    • 2013
  • As a result of the advantages such as high efficiency, continuous current and high stability margin, push-pull converter with continuous current (PPCWCC) is competitive for battery discharge regulator (BDR) which plays an important role in power conditioning unit (PCU). Leakage inductance yields current spike in low-ripple current of PPCWCCs. The operating modes are added due to leakage inductance. Therefore the steady state performance is affected, which is embodied in the spike of low-ripple current. PPCWCCs which are suitable for BDR can be separated into three types by current spike characteristics. Three representative topologies IIs1, IIcb2 and Is3 are analyzed in order to investigate the factors on the magnitude and duration of spike. Equivalent current sampling method (ECSM) which eliminates the sampling time delay and achieves excellent dynamic performance is adopted to prevent the spike disturbance on current sampling. However, ECSM reduces the sampling accuracy and telemetry accuracy due to neglecting the spike. In this paper, ECSM used in PPCWCCs is summarized. The current sampling error is analyzed in quality and quantity, which provides the foundation for offsetting and enhancing the telemetry accuracy. Finally, current sampling error rate of three topologies is compared by experiment results, which verify the theoretical analysis.

위치 기반 시스템을 위한 CMOS IR-UWB RFIC (A CMOS IR-UWB RFIC for Location Based Systems)

  • 이중무;박명철;어윤성
    • 전자공학회논문지
    • /
    • 제52권12호
    • /
    • pp.67-73
    • /
    • 2015
  • 본 논문에서는 근거리 위치 기반 시스템을 위한 3 - 5 GHz IR-UWB(impulse radio-ultra wide band) RFIC를 제안한다. 수신기의 구조는 에너지 검출 방식으로 설계되었고, 고속 sampling을 하기 위해서 4 bit ADC 와 DLL(delay locked loop) 을 이용하여 equivalent-time sampling 기술을 사용하도록 설계되었다. 송신기는 저전력의 디지털 UWB impulse generator 를 설계하였다. 설계된 IR-UWB RFIC 는 CMOS $0.18{\mu}m$ 공정을 이용하여 제작되었다. 측정된 수신기의 감도는 -85.7 dBm 이며, 송신기와 수신기는 1.8 V 전원 전압에서 각각 32 mA 와 25.5 mA 의 전류를 소모한다.

Fast Switching Direct Torque Control Using a Single DC-link Current Sensor

  • Wang, Wei;Cheng, Ming;Wang, Zheng;Zhang, Bangfu
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.895-903
    • /
    • 2012
  • This paper presents a fast switching direct torque control (FS-DTC) using only a single DC-link current sensor. In FS-DTC, six new active voltage complex space vectors (CSVs) are synthesized by the conventional active voltage space vectors (SVs). The corresponding sectors are rotated in the anticlockwise direction by 30 degrees. A selection table is defined to select the CSVs. Based on the "Different Phase Mode", the output sequence of the selected CSV is optimized. Accordingly, a reconstruction method is proposed to acquire the phase currents. The core of the FS-DTC is that all of the three phase currents can be reliably reconstructed during every two sampling periods, which is the result of the fast switching between different phases. The errors between the reconstructed and actual currents are strictly limited in one sampling period. The FS-DTC has the advantages of the standard DTC scheme such as simple structure, quick torque response and robustness. As can be seen in the analysis, the FS-DTC can be thought of as an equivalent standard DTC scheme with 86.6% of the maximum speed, 173.2% of the torque ripple, and 115% of the response time of the torque. Based on a dSPACE DS1103 controller, the FS-DTC is implemented in an induction machine drive system. The results verify the effectiveness of the FS-DTC.

노래연습장, 유흥·단란주점의 음악저작물이용 실태조사 개선안 연구 (An Improved Sample Design for Estimating the Usage of Copyrighted Music Works)

  • 이계오;정연수
    • Communications for Statistical Applications and Methods
    • /
    • 제19권3호
    • /
    • pp.315-331
    • /
    • 2012
  • 2011년 3월 오프라인 노래연습장, 유흥 단란주점 표본조사업소에서 수집한 곡목별 히팅수 로그데이터로부터 강남지부 등 총 11개 지부의 히팅수와 히팅수 표본오차를 추정하였다. 업소에서 징수한 음악저작물 사용료를 추정된 곡목별 히팅수를 기준으로 관계권리자(작곡, 작사, 편곡자 등)에게 분배하는 현행 분배방식에 따라 표본오차 규모를 금액으로 환산하여 크기를 검토하였다. 기존표본은 과소하여 히팅수 추정시 표본오차를 과다하게 발생시켰으며, 본 연구에서는 히팅수 추정오차를 줄여 음악저작권사용료 분배에 형평성을 기할 수 있는 합리적인 표본크기 개선방안을 제안하였다.

Improved Digital Redesign for Fuzzy Systems: Compensated Bilinear Transform Approach

  • 김도완;주영훈;박진배
    • 한국지능시스템학회논문지
    • /
    • 제15권6호
    • /
    • pp.765-770
    • /
    • 2005
  • This paper presents a new intelligent digital redesign (IDR) method via the compensated bilinear transformation to design the digital controller such that the digital fuzzy system is equivalent to the analog fuzzy system in the sense of the state-matching. This paper especially consider a multirate control scheme with a predictive feature, where the digital control input is held constant N times between the sampling points. More precisely, the multirate control scheme is proposed that utilizes a numerical integration scheme to approximately predict the current state from the state measured at the sampling points, the delayed measurements. For this system, the IDR conditions incorporated with stabilizability in the format of the linear matrix inequalities (LMIs) are derived. The superiority of the proposed technique is convincingly visualized through a numerical example.

Estimation of ESR in the DC-Link Capacitors of AC Motor Drive Systems with a Front-End Diode Rectifier

  • Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.411-418
    • /
    • 2015
  • In this paper, a new method for the online estimation of equivalent series resistances (ESR) of the DC-link capacitors in induction machine (IM) drive systems with a front-end diode rectifier is proposed, where the ESR estimation is conducted during the regenerative operating mode of the induction machine. In the first place, a regulated AC current component is injected into the q-axis current component of the induction machine, which induces the current and voltage ripple components in the DC-link. By processing these AC signals through digital filters, the ESR can be estimated by a recursive least squares (RLS) algorithm. To acquire the AC voltage across the ESR, the DC-link voltage needs to be measured at a double sampling frequency. In addition, the ESR current is simply reconstructed from the stator currents and switching states of the inverter. Experimental results have shown that the estimation error of the ESR is about 1.2%, which is quite acceptable for condition monitoring of the capacitor.

전기접촉저항에 관한 접촉통계치의 영향 (Effect of Contact Statistics on Electrical Contact Resistance)

  • 장용훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1080-1085
    • /
    • 2003
  • The flow of electrical current through a microscopic actual contact spot between two conductors is influenced by the flow through adjacent contact spots. A smoothed version of this interaction effect is developed and used to predict the contact resistance when the statistical size and spatial distribution of contact spots is known. To illustrate the use of the method, an idealized fractal rough surface is defined using the random midpoint displacement algorithm and the size distribution of contact spots is assumed to be given by the intersection of this surface with a constant height plane. With these assumptions, it is shown that including finer scale detail in the fractal surface, equivalent to reducing the sampling length in the measurement of the surface, causes the predicted resistance to approach the perfect contact limit.

  • PDF

Capacitive Readout Circuit for Tri-axes Microaccelerometer with Sub-fF Offset Calibration

  • Ouh, Hyun Kyu;Choi, Jungryoul;Lee, Jungwoo;Han, Sangyun;Kim, Sungwook;Seo, Jindeok;Lim, Kyomuk;Seok, Changho;Lim, Seunghyun;Kim, Hyunho;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.83-91
    • /
    • 2014
  • This paper presents a capacitive readout circuit for tri-axes microaccelerometer with sub-fF offset calibration capability. A charge sensitive amplifier (CSA) with correlated double sampling (CDS) and digital to equivalent capacitance converter (DECC) is proposed. The DECC is implemented using 10-bit DAC, charge transfer switches, and a charge-storing capacitor. The DECC circuit can realize the equivalent capacitance of sub-fF range with a smaller area and higher accuracy than previous offset cancelling circuit using series-connected capacitor arrays. The readout circuit and MEMS sensing element are integrated in a single package. The supply voltage and the current consumption of analog blocks are 3.3 V and $230{\mu}A$, respectively. The sensitivities of tri-axes are measured to be 3.87 mg/LSB, 3.87 mg/LSB and 3.90 mg/LSB, respectively. The offset calibration which is controlled by 10-bit DECC has a resolution of 12.4 LSB per step with high linearity. The noise levels of tri-axes are $349{\mu}g$/${\sqrt}$Hz, $341{\mu}g$/${\sqrt}$Hz and $411{\mu}g$/${\sqrt}$Hz, respectively.

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

한국산 유독 남조류의 독소함량을 근거로 한 조류경보제 발령기준 검토 (Investigation of Criterion on Harmful Algae Alert System using Correlation between Cell Numbers and Cellular Microcystins Content of Korean Toxic Cyanobacteria)

  • 박혜경;김화빈;이재정;이재안;이혜진;박종환;서정관;윤석제;문정숙
    • 한국물환경학회지
    • /
    • 제27권4호
    • /
    • pp.491-498
    • /
    • 2011
  • We investigated the ranges of total cellular microcystins content of cyanobacterial blooms collected in Korean lakes and rivers from 2005 to 2009. The amount and composition of microcystins of Korean cyanobacteria varied depending on the sampling water bodies and dominant cyanobacterial genera. Toxic cyanobacterial cell numbers equivalent to $1{\mu}g$ MCYSTs/L using total cellular microcystin content of Korean cyanobacteria were in the range of 2,348 to 66,980,638 cells/mL. Only four samples among forty nine samples showed less cell numbers than current criterion of Harmful Algae Alert System, 5,000 cells/mL indicating current criterion do not reflect properly the microcystins content of Korean cyanobacteria. Anabaena and Aphanizomenon spp. showed three to six times higher cell numbers equivalent to $1{\mu}g$ MCYSTs/L than Microcystis spp. To propose criteria of Harmful Algae Alert System for Korean toxic cyanobacteria, we calculated about 50% selective geometrical means of cyanobacterial cell numbers equivalent to $1{\mu}g$ MCYSTs/L in order of toxic content. The proposed criteria for Microcystis, Oscillatoria, Anabaena, and Aphanizomenon spp., are 10,000, 20,000, 40,000, and 80,000 cells/mL, respectively.