• Title/Summary/Keyword: Equivalent Winding

Search Result 137, Processing Time 0.04 seconds

A Voltage Vector Synchronization Method for a Renewable Energy System with a Doubly-Fed Induction Generator (권선형유도발전기를 갖는 신재생에너지 시스템을 위한 전압벡터 동기화 기법)

  • Park, Jung-Woo;Lee, Ki-Wook;Kim, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.547-555
    • /
    • 2007
  • In order to transmit energy generated through the stator winding of a doubly-fed induction generator (DFIG), we need to synchronize the generated voltage vector with the grid voltage vector. However, the existing synchronization methods work only when the encoder is installed at a specific position and equivalent constant is precise. In order to solve this problem, a new synchronization method has been proposed and a way of applying the method to existing doubly-fed induction generator control algorithm has been also proposed. The validities of the methods proposed were verified by using a prototype converter for a 1.5MW-class doubly-fed induction generator and experimental results showed the validity of that against variation of an encoder positions, generator parameters, and grid voltages.

Experimental Verifications and Electromagnetic Characteristics Analysis of Multi-Pole Permanent Magnet Generator for Small-Scaled Wind Power System (소용량 풍력시스템을 위한 다극 영구자석형 발전기의 전자기적 특성 해석 및 실험적 검증)

  • Jang, Seok-Myeong;Ko, Kyoung-Jin;Kim, Hyun-Kyu;Choi, Jang-Young;Yoon, Gi-Gap
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.609_610
    • /
    • 2009
  • This paper deals with experimental verifications and the electromagnetic characteristics analysis of multi-pole permanent magnet (PM) generator for small-scaled wind power system. Field distribution due to PMs and winding current, cogging torque considering skew effect are analyzed. In addition, using the equivalent circuit method and dynamic d-q method, generating performance analysis is performed. Analysis results are validated by comparison with nonlinear finite element analyses and experimental results.

  • PDF

Optimal design for tooth and yoke width of distributed winding motor for maximum output (분포권 전동기의 출력향상을 위한 치 폭과 요크 폭의 최적 설계)

  • Kim, Hae-Joong;Kwon, Soon-O;Lee, Jin-Gyu;Sun, Tao;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.816_817
    • /
    • 2009
  • Optimization of geometry is one of the most important design process of the electrical motors. Tooth and yoke width are important variables that can maximize back emf and load torque among various design parameters. In this paper, in order to design the tooth and yoke width effectively, an equivalent magnetic circuit of one pole is constructed and an optimal value of tooth and yoke width resulting minimum reluctance are determined instead of a finite element analysis(FEA) that is time consuming.

  • PDF

Control Method of a Doubly-fed Induction Generator with Grid Synchronization unaffected by encoder position (엔코더 위치에 강인한 계통연계 기능을 갖는 권선형유도발전기 제어 기법)

  • Park, Jung-Woo;Lee, Ki-Wook;Kim, Dong-Wook;Lee, Kwang-Soo;Park, Jin-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.125-129
    • /
    • 2006
  • In order to transmit energy generated through the stator winding of a doubly-fed Induct ion generator (DFIG), we need to synchronize the generated voltage vector with the grid voltage vector. However, the existing synchronization method works only when the encoder is installed at a specific Position and equivalent constant is precise. In order to solve this Problem, a new synchronization method has been proposed and a way of applying the method to existing doubly-fed induction generator control algorithm has been also proposed. The validity of the proposed methods have been verified using a prototype converter for the control of a 1.5MW-class doubly-fed induction generator

  • PDF

Steady-State Characteristics of the Piezoelectric Transformer and the Design of the Piezoelectric Inverter (압전 변압기 정상상태 특성과 고효율 냉 음극 방전등용 인버터 설계)

  • Kweon, G.H.;Lim, Y.C.;Yang, S.H.;Jung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2616-2619
    • /
    • 1999
  • The Backlight inverter used in the laptop computer is designed in this study. It has been difficult for electromagnetic transformer to enhance the efficiency and compact profile. In this study, (l) the piezoelectric transformer(PT) is used for reducing the loss: (2) the volume of core and winding coil are used in electromagnetic transformer, and (3) the zero voltage switching(ZVS) is used in the driver of the resonant circuit. The modified PT for this paper and the equivalent circuit are supported by the simulation program. ZVS is achieved by Half-Bridge inverter circuit. The result of the experiment shows more than 91% improvement in terms of the efficiency.

  • PDF

A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear (Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究))

  • Kim, S.K.;Kim, T.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

A Study on Saturation Modeling of Synchronous Generator using Operating Data (운용 데이타를 이용한 동기발전기 포화 모델링에 관한 연구)

  • Kim, Kyung-Yul;Yoo, Ill-Do;Seo, Jang-Cheol;Moon, Seung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.106-109
    • /
    • 1995
  • This paper presents a new saturation modeling technique of synchronous generators using the operating data. With the stator voltages, currents and the field current directly measured on the field winding at different steady state operating conditions, it can estimate tile saturated stator mutual inductances, stator resistance and the field-stator equivalent turns ratio. Effects of the measurement noises on tile estimated parameters are also investigated.

  • PDF

Experimental Verification and Prediction of Generating Performance of PMG with Multi-Pole Rotor based on Electromagnetic Analysis and Parameter Estimation considering Skew Effects (스큐를 고려한 다극 영구자석 발전기의 전자기 특성해석/제어정수 도출을 통한 발전특성 예측 및 실험적 검증)

  • Jang, Seok-Myeong;Choi, Jang-Young;Ko, Kyoung-Jin;Park, Ji-Hoon;Lee, Sung-Ho;Kim, Ii-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.752-753
    • /
    • 2008
  • The analytical expressions for magnetic field distributions considering slotting effects, cogging torque and back-emf considering skew effects are established. On the basis of magnetic field solutions, electrical parameters such as back-emf constant and winding inductance are obtained. The predicted results are validated extensively by non-linear finite element (FE) analyses. In particular, test results such as back-emf, cogging torque, inductance and resistance measurements are given to confirm the analyses. Finally, generating performances are investigated by applying estimated parameters to equivalent circuit (EC) of the permanent magnet generator (PMG) and validated extensively by FE calculations and measurements.

  • PDF

A analysis result on the PT ferroresonance at 154 kV GIS substation (154 kV GIS의 PT 철공진 소손사례와 원인규명)

  • Woo, J.W.;Shim, E.B.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2076-2079
    • /
    • 1999
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP (Electro-magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

Series-parallel resonant converter using a contactless power supply for the efficiency improvement (효율 개선을 위한 직${\cdot}$병렬 공진컨버터 적용 비접촉 전원)

  • Kong Y.S.;Lee H.K.;Kim E.S.;Cho J.G.;Kim J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • To improve the efficiency characteristics in the resonant converter using the contact-less power supply with the large air-gap and the long primary winding, this paper suggests the three-level series-parallel resonant converter(SPRC). The voltage gain characteristics of the proposed converter have the unit gain in a resonance frequency point of the series and parallel, and input voltage and current in the primary of SPRC are always In phase for the all equivalent load resistance because of the parallel resonant tank of the high impedance. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental prototype.

  • PDF