• Title/Summary/Keyword: Equivalent U-value

Search Result 33, Processing Time 0.226 seconds

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

Dynamic Pyroelectric Properties and Their Frequency Dependences of $LiTaO_3$ Crystal ($LiTaO_3$ crystal의 dynamic 초전특성과 그 주파수의 의존성)

  • Lee, Won-Jae;Kang, Seong-Jun;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.35-41
    • /
    • 2000
  • The frequency dependence of the pyroelectric characteristics of $LiTaO_3$ have been investigated by using the dynamic method. In the frequency range between 2 and 1000 Hz, they are measured in both the regimes of pyroelectric current ($R_L=1M{\Omega}$) and pyrelectric voltage ($R_L=17.3G{\Omega}$), which can be selected by adjusting the value of the load resistance. Pyroelectric coefficient depending on the voltage response in the regime of pyroelectric current shows the maximum value of $1.56{\times}10^{-8}C/cm^2{\cdot}K$ at 40 Hz. The maximum values of figures of merits for the voltage response and for the detectivity are measured as $10.8{\times}10^{-11}C{\cdot}cm/J$ and $13{\times}10^{-7}C{\cdot}cm/J$, respectively. The voltage responsivity depending on the voltage response in the regime of pyroelectrci voltage shows the maximum value of 488 V/W at 2 Hz. Noise equivalent power and detectivity shows the minimum value of $3.95{\times}10^{-10}W/{\sqrt}Hz$ and maximum value of $5.6{\times}10^8cm{\cdot}{\sqrt}Hz/W$ at 40 Hz, respectively.

  • PDF

An Experimental Study on In-Plate Evaporation Heat Transfer and Flow Characteristics for Automobile (자동차용 증발기 판 내의 증발 열전달 및 유동 특성에 관한 실험적 연구)

  • Kwak, Kyung-Min;Joo, Sang-Woo;Jung, Woo-Youl;Kim, Taek-Keun;Kim, Kwang-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.95-100
    • /
    • 2007
  • An experimental study was performed to evaluate the in-plate evaporation heat transfer and flow characteristics of a evaporator used in automobile. Two test-cores with different heat transfer area, bead-shape and bead-array were tested, A type and B type. For the heat transfer, Nusselt number for B type test-core reaches a value nearly equal to the one for A type test-core, in the whole range of equivalent Reynolds number. But, for the same mass flow rate of refrigerant, hA for B type test-core becomes higher with the increase of the mass quality of refrigerant than for A type test-core. In a flow visualization experiment, the wake zone of refrigerant circulating at u-turn position of plate is observed.

A Study on the Analysis of Power Load Density and Electric Power Consumption in Apartment Housing (아파트의 전력부하밀도 및 전력소비 실태 분석 연구)

  • 이기홍;성세진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.118-124
    • /
    • 2001
  • To guide the esti-on of electric d e d and energy saving, this proposed the Power Laaddensity, Elechic pwer consumption and the installed state of Power facility. For this purp~se, it wasconducted a questionnaire survey of the consumption-cattern of Electric power in 1W a p a r t t housings.As a 1-esult it is found that (i) the d m u m value of Power Load density is 7.70[~A/m"l, (ii) the avtragevalue of Power Load dens'||'&'||' is ~ . ~ A / mm' dl (iiijthe average load rate is Ed[%]. Also, the consumptionof electricity one year at tlie whole a m n t s of couniry is 14,0X[GWyearl, it was equivalent to 7[%1 ofthe total-consunmhon of electricity one year at the whole of co1mtnr. co1mtnr.

  • PDF

Memory Organization for a Fuzzy Controller.

  • Jee, K.D.S.;Poluzzi, R.;Russo, B.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1041-1043
    • /
    • 1993
  • Fuzzy logic based Control Theory has gained much interest in the industrial world, thanks to its ability to formalize and solve in a very natural way many problems that are very difficult to quantify at an analytical level. This paper shows a solution for treating membership function inside hardware circuits. The proposed hardware structure optimizes the memoried size by using particular form of the vectorial representation. The process of memorizing fuzzy sets, i.e. their membership function, has always been one of the more problematic issues for the hardware implementation, due to the quite large memory space that is needed. To simplify such an implementation, it is commonly [1,2,8,9,10,11] used to limit the membership functions either to those having triangular or trapezoidal shape, or pre-definite shape. These kinds of functions are able to cover a large spectrum of applications with a limited usage of memory, since they can be memorized by specifying very few parameters ( ight, base, critical points, etc.). This however results in a loss of computational power due to computation on the medium points. A solution to this problem is obtained by discretizing the universe of discourse U, i.e. by fixing a finite number of points and memorizing the value of the membership functions on such points [3,10,14,15]. Such a solution provides a satisfying computational speed, a very high precision of definitions and gives the users the opportunity to choose membership functions of any shape. However, a significant memory waste can as well be registered. It is indeed possible that for each of the given fuzzy sets many elements of the universe of discourse have a membership value equal to zero. It has also been noticed that almost in all cases common points among fuzzy sets, i.e. points with non null membership values are very few. More specifically, in many applications, for each element u of U, there exists at most three fuzzy sets for which the membership value is ot null [3,5,6,7,12,13]. Our proposal is based on such hypotheses. Moreover, we use a technique that even though it does not restrict the shapes of membership functions, it reduces strongly the computational time for the membership values and optimizes the function memorization. In figure 1 it is represented a term set whose characteristics are common for fuzzy controllers and to which we will refer in the following. The above term set has a universe of discourse with 128 elements (so to have a good resolution), 8 fuzzy sets that describe the term set, 32 levels of discretization for the membership values. Clearly, the number of bits necessary for the given specifications are 5 for 32 truth levels, 3 for 8 membership functions and 7 for 128 levels of resolution. The memory depth is given by the dimension of the universe of the discourse (128 in our case) and it will be represented by the memory rows. The length of a world of memory is defined by: Length = nem (dm(m)+dm(fm) Where: fm is the maximum number of non null values in every element of the universe of the discourse, dm(m) is the dimension of the values of the membership function m, dm(fm) is the dimension of the word to represent the index of the highest membership function. In our case then Length=24. The memory dimension is therefore 128*24 bits. If we had chosen to memorize all values of the membership functions we would have needed to memorize on each memory row the membership value of each element. Fuzzy sets word dimension is 8*5 bits. Therefore, the dimension of the memory would have been 128*40 bits. Coherently with our hypothesis, in fig. 1 each element of universe of the discourse has a non null membership value on at most three fuzzy sets. Focusing on the elements 32,64,96 of the universe of discourse, they will be memorized as follows: The computation of the rule weights is done by comparing those bits that represent the index of the membership function, with the word of the program memor . The output bus of the Program Memory (μCOD), is given as input a comparator (Combinatory Net). If the index is equal to the bus value then one of the non null weight derives from the rule and it is produced as output, otherwise the output is zero (fig. 2). It is clear, that the memory dimension of the antecedent is in this way reduced since only non null values are memorized. Moreover, the time performance of the system is equivalent to the performance of a system using vectorial memorization of all weights. The dimensioning of the word is influenced by some parameters of the input variable. The most important parameter is the maximum number membership functions (nfm) having a non null value in each element of the universe of discourse. From our study in the field of fuzzy system, we see that typically nfm 3 and there are at most 16 membership function. At any rate, such a value can be increased up to the physical dimensional limit of the antecedent memory. A less important role n the optimization process of the word dimension is played by the number of membership functions defined for each linguistic term. The table below shows the request word dimension as a function of such parameters and compares our proposed method with the method of vectorial memorization[10]. Summing up, the characteristics of our method are: Users are not restricted to membership functions with specific shapes. The number of the fuzzy sets and the resolution of the vertical axis have a very small influence in increasing memory space. Weight computations are done by combinatorial network and therefore the time performance of the system is equivalent to the one of the vectorial method. The number of non null membership values on any element of the universe of discourse is limited. Such a constraint is usually non very restrictive since many controllers obtain a good precision with only three non null weights. The method here briefly described has been adopted by our group in the design of an optimized version of the coprocessor described in [10].

  • PDF

A Study on the Diagnosis of Secondary Battery by Phase Response (위상응답에 의한 이차전지의 진단에 관한 연구)

  • Park, Seung-Gon;Kang, Dea-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.99-104
    • /
    • 2019
  • It was proposed the use of an inducive element to measure the SOH of a secondary battery by phase response. As a result of simulating the Randles equivalent model of a secondary battery, the inductive element used as the load has a high response characteristic and increases the maximum phase response frequency band. In order to obtain the frequency band in which the phase response characteristic of the secondary battery is well observed, the phase response was measured with the change of the inductance value of the inductive element, 33uH,49mohm inductive element with the maximum phase response at 631Hz was used. The phase response measurements for secondary battery with different SOH showed that the phase response for each 20% of SOH showed a difference of about 3.8(degree), enabling the SOH diagnosis of secondary battery by the phase measurement for the inductive element.

The engineering merit of the "Effective Period" of bilinear isolation systems

  • Makris, Nicos;Kampas, Georgios
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.397-428
    • /
    • 2013
  • This paper examines whether the "effective period" of bilinear isolation systems, as defined invariably in most current design codes, expresses in reality the period of vibration that appears in the horizontal axis of the design response spectrum. Starting with the free vibration response, the study proceeds with a comprehensive parametric analysis of the forced vibration response of a wide collection of bilinear isolation systems subjected to pulse and seismic excitations. The study employs Fourier and Wavelet analysis together with a powerful time domain identification method for linear systems known as the Prediction Error Method. When the response history of the bilinear system exhibits a coherent oscillatory trace with a narrow frequency band as in the case of free vibration or forced vibration response from most pulselike excitations, the paper shows that the "effective period" = $T_{eff}$ of the bilinear isolation system is a dependable estimate of its vibration period; nevertheless, the period associated with the second slope of the bilinear system = $T_2$ is an even better approximation regardless the value of the dimensionless strength,$Q/(K_2u_y)=1/{\alpha}-1$, of the system. As the frequency content of the excitation widens and the intensity of the acceleration response history fluctuates more randomly, the paper reveals that the computed vibration period of the systems exhibits appreciably scattering from the computed mean value. This suggests that for several earthquake excitations the mild nonlinearities of the bilinear isolation system dominate the response and the expectation of the design codes to identify a "linear" vibration period has a marginal engineering merit.

The registration and approval of Oriental Medical devices for the entry into U.S. market (한방의료기기의 미국 시장 진출을 위한 심사제도 소개)

  • Oh, Ji Yun;Choi, Yu Na;Jo, Su Jeong;Jung, Chan Yung;Cho, Hyun Seok;Lee, Seung Deok;Kim, Kap Sung;Kim, Eun Jung
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.91-102
    • /
    • 2015
  • Objectives : The Oriental medical device industry is expected to continue to experience significant growth. It should increase its global market share rather than focusing on the domestic market. Countries around the world self-regulate their domestic market, so this study aims to aid in the development of a particular overseas market by introducing the U.S.(the largest market) medical device registration and approval process. Methods : For an understanding of the US medical device licensing process, we researched the relevant regulatory organization (FDA), the history, definition and classification of medical devices, the approval and 510(k) submission process related to substantial equivalence, IEC 60601-1 Edition 3, usability tests, and so on. Results : Medical devices in the United States are assigned to one of three regulatory classes: Class I, Class II and Class III, based on the level of control necessary to assure the safety and effectiveness of the device. If a company's device is classified as Class II and if it is not exempt, a 510k will be required for marketing. 1) A 510(k) is a premarket submission made to the FDA to demonstrate that the new device to be marketed is "substantially equivalent" to a legally marketed device (predicate device) 2) The IEC 60601-1 Edition 3 preparation process, which contains information related to usability, is expensive and time-consuming but a critical requirement. Conclusions : Although the U.S. market has high barriers to entry, access to this, large overseas market will encourage development of the Oriental medical device industry and commercial value enhancement is expected.

On the Accuracy of Calculation in the Analysis of Natural Transverse Vibrations of a Ship's Hull (선체고유횡진동해석(船體固有橫振動解析)에 있어서의 계산정도(計算精度))

  • K.C.,Kim;H.S.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • Using the computer programs for calculation of natural vibrations of ship's hull developed by the authors et al., an investigation into influences of various parameters on the accuracy of calculation was done through example calculations of a 30,000 DWT petroleum products carrier M/S Sweet Brier built by Korea Shipbuilding and Engineering Corporation. The methodical principles employed for the computer program development are as follows; (a) the ship system is reduced to an equivalent discrete elements system conforming to Myklestad-Prohl model, (b) the problem formulation is of transfer matrix method, and (c) to obtain solutions an extended $G\ddot{u}mbel's$ initial value method is introduced. The scope of the investigation is influences of number of discrete elements, choice of significant system parameters such as rotary inertia, bending stiffness and shear stiffness, and simplification of distributions of added mass and stiffness as trapezoidal ones referred to those of midship section on the calculation accuracy. From the investigation the followings are found out; (1) To obtain good results for the modes up to the seven-noded thirty or more divisions of the hull is desirable. For fundamental mode fifteen divisions may give fairly good results. (2) The influence of rotary inertia is negligibly small at least for the modes up to the 5- or 6- noded. (3) In the case of assuming either bending modes or shear modes the calculation results in considerably higher frequencies as compared with those based on Timoshenko beam theory. However, the calculation base on the slender beam theory surprisingly gives frequencies within 10% error for fundamental modes. (4) It is proved that to simplify distributions of added mass and stiffness as trapezoidal ones referred to those of midship section is a promising approach for the prediction of natural frequencies at preliminary design stage; provided good accumulation of data from similar type ships, we may expect to obtain natural frequencies within 5% error.

  • PDF

The Effect of Qigong on the Health Promotion in Post-mastectomy Women (기공(氣功)이 유방절제술을 받은 여성의 건강증진에 미치는 영향)

  • Kim, Yi-Soon;Kim, Gyeong-Cheol;Kwak, Yi-Sub;Lee, Hai-Woong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2010
  • Objective : Qigong has been reported as an effective for post-mastectomy women. It consists of a series of postures combined with slow, smooth, graceful movements, and is considered a low intensity exercise. In this study, a specialist of Qigong developed a Qigong program for post-mastectomy women in a community. The object of this research is to evaluate the effect of Qigong on a subjective symptom scale, on the grade of discomfort and pain in everyday life, BMI, fat(%), muscular strength, shoulder joint movement, in post-mastectomy women. Methods : The study used a non-equivalent control group non-synchronized design. The experimental group received a Qigong 3 times a week for 12 weeks from September 7th to December 28th in 2009. The subjects were 40 patients are divided into 25 persons in experimental groups and 15 persons in contrastive group. The data were analyzed with descriptive statistics, chi-square test, t-test, Mann-Whitney U test. A P-value less than .05 was considered significant by 2-tailed test. All statistical analyses were performed with SPSS win(ver 12.0). Results : The results were as follows : The score in the subjective symptom(p=.040), and score of anxiety (p=.024), fat(%)(p=.007) were significantly decreased after Qigong program. The values for shoulder flexibility (left : p=.010, right : p=.008), and Muscular strength(grip power)(left : p=.021, right : p=.029) significantly increased after Qigong program. And Flexion(left ; p=.029), Extension(left : p=.001, right : p=.038), Adduction(left ; p=.001, right ; p<0.001) were also significantly increased after Qigong Conclusions : The Qigong is an effective health promotion program for post-mastectomy women.