• Title/Summary/Keyword: Equivalent Conductivity

Search Result 156, Processing Time 0.023 seconds

Grain Size Analysis by Hot-Cooling Cycle Thermal Stress at Y-TZP Ceramics using Full Width at Half Maximum(FWHM) of X-ray Diffraction (X-ray 회절의 반치전폭(FWHM)을 이용한 Y-TZP세라믹스에서 반복 열응력에 의한 입계크기 분석)

  • Choi, Jinsam;Park, Kyu Yeol;Kong, Young-Min
    • Korean Journal of Materials Research
    • /
    • v.29 no.4
    • /
    • pp.264-270
    • /
    • 2019
  • As a case study on aspect ratio behavior, Kaolin, zeolite, $TiO_2$, pozzolan and diatomaceous earth minerals are investigated using wet milling with 0.3 pai media. The grinding process using small media of 0.3 pai is suitable for current work processing applications. Primary particles with average particle size distribution D50, ${\sim}6{\mu}m$ are shifted to submicron size, D50 ${\sim}0.6{\mu}m$, after grinding. Grinding of particles is characterized by various size parameters such as sphericity as geometric shape, equivalent diameter, and average particle size distribution. Herein, we systematically provide an overview of factors affecting the primary particle size reduction. Energy consumption for grinding is determined using classical grinding laws, including Rittinger's and Kick's laws. Submicron size is obtained at maximum frictional shear stress. Alterations in properties of wettability, heat resistance, thermal conductivity, and adhesion increase with increasing particle surface area. In the comparison of the aspect ratio of the submicron powder, the air heat conductivity and the total heat release amount increase 68 % and 2 times, respectively.

Precise Control of Nutrient Solution and Analysis of Ionic Contribution to EC Reading (양액의 정밀 제어 및 이온의 EC 기여도 분석)

  • Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.352-354
    • /
    • 1998
  • A soilless culture system with the precise control of nutrient solution was developed and the time changes of ionic contribution to EC reading was analyzed. The measuring device designed was able to wash electrodes cleanly and to measure the pH and EC of nutrient solution stably in the box. The nutrient supply system using metering device was also able to control the EC and pH within ${\pm}0.05mS/cm$ and ${\pm}0.05$, respectively. Under the EC control, activity coefficients of all ions decreased with time as ionic concentrations of $SO_4$, Mg and Ca increased due to the selective nutrient absorption by plants. Time changes of ionic contribution to EC reading could be calculated using equivalent ionic conductivities and activity coefficients obtained by numerical analysis.

  • PDF

A Study on a Classification Technique of Natural Mineral Waters by Its Constitution and Physico-Chemical Properties (鑛泉水 理化學的 水質評價 技法 에 관한 연구)

  • Nam, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.33-38
    • /
    • 1988
  • Natural mineral water is generally quite different from ordinary drinking water due to its original nature and various properties. The complexity of natural mineral water requires, therefore, not only to identify its nature and proper characteristics, but also to classify them by a reasonable scientific basis of comparison. The study was concentrated on a possible classification technique to natural mineral waters by their constitutions and physico-ehemical properties. The classification was carried out by the computation of such numerical parameters as ionic equivalent percentage, electrolytic conductance or mobility, ionic molecular weight, molecular concentration, equivalent conductivity and degree of ionization in consideration of the determinative criteria as follows -particular single element or molecule -major components of natural waters as bicarbonate, sulphate, chloride,caloride, calcium, magnesium, and sodium -moleculat concentration related to blood osmotic pressure -water temperature at emergence from spring -contents of free carbon dioxide (CO2) -pH value of water -total dissolved solids or salts (NaCl) The results obtained proved out to be clearly distinguhhable from ordinary drinking water as far as concern natural mineral water as an example on the subject -simple water -bicarbonate-predominating water -cold spring -carbonated-non gaseous water -weak alkaline water -non saline water Putting these various results together, the sample turned out to be a kind of natural mineral water that can be used as a drinking water if microbiologically safe.

  • PDF

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

A Study on the Electrochemical Micro-machining for Fabrication of Micro Grooves (미세 홈 형성을 위한 마이크로 전해가공에 관한 연구)

  • Park, Jeong-Woo;Lee, Eun-Sang;Moon, Young-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2002
  • A specially-built EMM (Electrochemical Micro Machining) / PECM (Pulse Electrochemical Machining) cell, a electrode tool filled with non-conducting material, a electrolyte flow control system and a small & stable gap control unit are developed to achieve accurate dimensions of recesses. Two electrolytes, aqueous sodium nitrate and aqueous sodium chloridc arc applied in this study. The farmer electrolyte has better machine-ability than the latter one because of its appropriate changing to the transpassive state without pits on the surface of workpiece. It is easier to control the machining depth precisely by micrometer with pulse current than direct current. This paper also presents an identification method for the machining depth by in-process analysis of machining current and inter electrode gap size. The inter electrode gap characteristics, inc1uding pulse current, effective volumetric electrochemical equivalent and electrolyte conductivity variations, are analyzed based on the model and experiments.

Energy and Speed Characteristics of Induction Coil-Gun (유도형 코일건의 에너지 및 속도특성 해석)

  • 장성만;김석환;한송엽;정현교
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.1
    • /
    • pp.69-74
    • /
    • 1992
  • This paper describes the energy and speed characteristics of an induction coil-gun. The coil-gun has some merits that it can be easily installed and repeatedly used many times, it does not damage mechanically in the course of launch and the force exerted on the projectile is distributed uniformly. An equivalent circuit is employed for modeling the coil-gun. The circuit equations and equation of motion are then derived based on the equivalent circuit. These equations are solved numerically by using Runge-Kutta method. Finally the energy transfer ratios are obtained according to the variations of the resonant frequency of driving circuit and charging voltage of capacitors. The muzzle velocities of projectile are also obtained according to the variations of electrical conductivity and initial position of projectile, firing angle of driving circuit, charging voltage of capacitor and resistance of driving coil, respectively.

  • PDF

A Study on the Design and the Analysis of Canned-motor for SMART(System integrated Modular Advanced Reactor) using the Equivalent Circuit with Consideration of the Can-loss (Can손실이 고려된 등가회로도를 이용한 SMART용 Canned-motor 설계 및 해석에 관한 연구)

  • Gu, Dae-Hyeon;Gang, Do-Hyeon;Park, Jeong-U;Kim, Jong-In;Park, Jin-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.483-493
    • /
    • 2001
  • The 3-phase induction is used for the MCP(main coolant pump) and the pure water is used for lubrication of bearing because of the difficulty of repair. Therefore the type of motor is the canned-motor that is welded by sealed can to prevent the stator and rotor from the lubricating water. A lot of Eddy currents are produced in the can because of the conductivity of material. And these eddy currents in the can are the most important cause that decrease the efficiency of induction motor. Therefore we have to find the method to decrease these eddy currents in the can for the improvement of efficiency of motor. In this paper, we proposed the method of design and analysis of canned-motor using equivalent circuit with consideration of can loss for the improvement of efficiency of motor.

  • PDF

A Performance Equation of Bath Tubs (욕조의 보온성능연구)

  • Lee, Byung-Ho;Suh, Jung-Il
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

Correlations between the Impedance and Compressive Strength of Hardened Cement According to the Aggregate Type

  • Hojin Kim;Jinju Kim;Sungyu Park;Je Hyun Bae
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.242-252
    • /
    • 2024
  • To date, methods used to assess the interfacial transition zone (ITZ), which represents the boundary between the aggregate and paste inside concretes, have primarily relied on destructive tests, and non-destructive tests has received little attention until recently. This study assessed the interfaces of concretes with lightweight aggregates based on electrochemical impedance spectroscopy (EIS) for high-strength concretes and examined the possibility of estimating the compressive strength of concretes through non-destructive testing using EIS. The experimental results revealed that the impedance of the hardened cement increased with increasing compressive strength and aggregate density. In particular, when the results of impedance measurement were displayed as a Nyquist plot, the intercept of the x-axis depicting the effective conductivity was proportional to the compressive strength. Furthermore, an equivalent circuit was selected to interpret the correlation between cement aggregates and impedance. Consequently, the compressive strength was found to increase with the value of the resistances of the electrolyte filled in continuous pores in the cement aggregate. And, the pores formed in the ITZ affect this value. The resistance at the ITZ for different aggregates was also obtained, and it was found that the resistance was consistent with the results predicted by SEM images of the ITZ and correlated with the strength of the concretes. The proposed method can be used as a way to easily determine the strength of cement according to differences in aggregate.

Mechanical and Electrical Properties of an Al-Fe-Mg-Cu-B System Alloy for Electrical Wire Fabricated by Wire Drawing (인발가공에 의해 제조된 전선용 Al-Fe-Mg-Cu-B계 합금의 기계적 및 전기적 특성)

  • Jung, Chang-Gi;Hiroshi, Utsunomiya;Son, Hyeon-Taek;Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.27 no.11
    • /
    • pp.597-602
    • /
    • 2017
  • In this study, an Al-0.7wt%Fe-0.2wt%Mg-0.2wt%Cu-0.02wt%B alloy was designed to fabricate an aluminum alloy for electrical wire having both high strength and high conductivity. The designed Al alloy was processed by casting, extrusion and drawing processes. Especially, the drawing process was done by severe deformation of a rod with an initial diameter of 12 mm into a wire of 2 mm diameter; process was equivalent to an effective strain of 3.58, and the total reduction in area was 97 %. The drawn Al alloy wire was then annealed at various temperatures of 200 to $400^{\circ}C$ for 30 minutes. The mechanical properties, microstructural changes and electrical properties of the annealed specimens were investigated. As the annealing temperature increased, the tensile strength decreased and the elongation increased. Recovery or/and recrystallization occurred as annealing temperature increased, and complete recrystallization occurred at annealing temperatures over $300^{\circ}C$. Electric conductivity increased with increasing temperature up to $250^{\circ}C$, but no significant change was observed above $300^{\circ}C$. It is concluded that, from the viewpoint of the mechanical and electrical properties, the specimen annealed at $350^{\circ}C$ is the most suitable for the wire drawn Al alloy electrical wire.