• Title/Summary/Keyword: Equivalence air ratio

Search Result 244, Processing Time 0.023 seconds

Combustion Characteristics of Stratified Mixture in a Constant Volume Combustion Chamber with Sub-chamber( I ) (부실식 정적연소실내 층상혼합기의 연소특성( I ))

  • Kim, B.S.;Kwon, C.H.;Ryu, J.I.;Ryu, J.I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.65-75
    • /
    • 1995
  • The present study was investigated combustion characteristics of methane-air mixtures at stratified charge in a constant volume combustion chamber. The results indicated that even the vety lean mixture, which is normally not flammable in single chamber type, could be burned within. a comparatively short time by using sub-chamber with stratified charge method. And the lean inflammability limit of mixture in a main chamber was about ($\phi_m$cr=O.46, when the equivalence ratio of a sub-chamber was $\phi_s$= 1.0. Initial time of pressure increase and total burning times were decreased and maximum combustion pressure. was increased as the equivalence ratio of both sub and main chamber approached unity. Specifically, initial time of pressure increase and total burning times were greatly affected rather by. the equivalence ratio of sub-chamber than that of main chamber. The maximum combustion pressure was little affected if the total equivalence ratio lies in the same range.

  • PDF

A Study of NO Formation Characteristics in Laminar Flames Using 2-D LIF Technique (2-D LIF를 이용한 층류화염의 NO 생성특성에 관한 연구)

  • Lee, Won-Nam;Cha, Min-Suk;Song, Young-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.38-48
    • /
    • 2003
  • OH, CH and NO radical distributions have been measured and compared with the numerical analysis results in methane/air partially premixed laminar flames using 2-D LIF technique. The pick intensity of OH LIF signal is insensitive to fuel equivalence ratio: however, CH LIF intensity decreases as equivalence ratio increases and the NO concentration increases with equivalence ratio. The contribution of the prompt NO, formed near premixed reaction zone, to the total NO formation is evident from the OH, CH, and NO PLIF images in which the dilution effect of nitrogen is minimal for the highest equivalence ratio. Measured OH and NO LIF signals in counterflow flames agree with the computed concentration distributions. Both numerical and experimental results indicate that the structural change in a flame alters the NO formation characteristics of a partially premixed counterflow flame. The nitrogen dilution also changes flame structure, temperature and OH radical distributions and results in the decreased NO concentrations in a flame. The levels of decrease in NO concentrations, however, depends on the premixedness(${\alpha}$) of a flame. The larger change in the flame structure and NO concentrations have been observed in a premixed flame(${\alpha}=1.0$), which implies that the premixedness is likely to be a factor in the dilution effect on NO formation of a flame.

  • PDF

A Study for Generating Power on Operating Parameters of Powerpack utilizng Linear Engine (리니어엔진을 이용한 파워팩의 운전조건에 따른 발전출력에 관한 연구)

  • Oh, Yong-Il;Kim, Gang-Chul;Lim, Ock-Taeck
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • The research shows the experiment results according to the combustion characteristics and configuration of the linear generator of powerpack for the generating power applying the 2-stroke compact linear engine. The powerpack used in this paper consists of 2-stroke linear engine, linear generator and air compressor parts. For identifying the combustion characteristics and generating power of linear engine, some parameters were varied sucha as electric load, fuel input calorie, spark timing delay and equivalence ratio. Also generating power was confirmed at each operation conditions, when the air gap length of linear generator part was changed as each 1.0 mm and 2.0 mm. During the all operations, intake air was inputted under the wide open throttle. Mass flow rate of air and fuel was changed using mass flow controller, after these were premixed by premixture device, and then premixed gas was supplied directly into each cylinder. As a result, piston frequency and combustion characteristics were different at each conditions according to parameters affecting the combustion such as fuel input calorie, resistive load, spark timing delay and equivalence ratio. Consequently, these had an effect on generating power.

A Study on Interacting $CH_4$-Air and $H_2/N_2$-Air Premixed Counterflow Flames (상호작용하는 메탄-수소 예혼합 대향류화염에 관한 연구)

  • Moon, Chang-Woo;Park, Jeong;Gwon, O.-Bung;Bae, Dae-Seok;Kim, Jeong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.1
    • /
    • pp.38-42
    • /
    • 2010
  • Using a counterflow burner, downstream interactions between $CH_4$-air and $H_2/N_2$-Air premixed flames with various equivalence ratios has been experimentally investigated. Flame stability maps on triple and twin flames are provided in terms of global strain rate and equivalence ratio. Lean and rich flammable limits are examined for methane/air and hydrogen/nitrogen/air mixtures over the entire range of mixture concentrations in the interacting flames. Results show that these flammable limits can be significantly modified in the presence of interaction such that mixture conditions beyond the flammability limit can be still burn if it is supported by stronger flame. The experiment also discusses various oscillatory instabilities in a stability map.

Detailed Local Chemiluminescence Measurement (OH*, CH* and C2*) and Nitrogen Oxides Emissions in Laminar Partially Premixed CH4/Air Flames (메탄/공기 층류 부분예혼합화염의 상세 라디칼(OH*, CH* 그리고 C2*) 정보와 배기매출물에 관한 실험적 연구)

  • Jeong Yong Ki;Oh Jeong Seog;Jeon Chung Hwan;Chang Young June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.263-270
    • /
    • 2005
  • An experimental study was performed to investigate the effects of partially premixing, varying the equivalence ratios from $0.79{\sim}{\infty}$, on NOx emissions and chemiluminescence of excited $OH^{\ast},\;CH^{ast}\;C_2^{\ast}$ radicals in laminar partially premixed flames. the signal from the electronically excited state of $OH^{\ast},\;CH^{ast}\;C_2^{\ast}$ was detected through a band pass filter with a photo multiplier tube, which are processed to the intensity ratio ($C_2^{\ast}/CH^{\ast},\;C_2^{\ast}/OH^{\ast},\;and\;CH^{\ast}/OH^{\ast}$) to reveal the correlation with local equivalence ratio. And measurements of NOx emission were made to investigate the relationship between visible flame appearance, chemiluminescence, and EINOX. The results demonstrated that (1) the flames at ${\phi}<1.59$ exhibited classical double flame structure, at ${\phi}>4.76$, the flames exhibited diffusion flame structure, and the intermediate flames at $1.59<{\phi}<4.76$ was a merged flame, (2) the $OH^{\ast}$ peak was located inside the $CH^{\ast}\;and\;C_2^{\ast}$ radical for all measured conditions and the emission intensity ratio of $C_2^{\ast}/CH^{\ast}\;and\;C_2^{\ast}/OH^{\ast}$ were identified as good marker for local equivalence ratio over a range of ${\phi}=0.79{\sim}1.2\;and\;CH^{\ast}/OH^{\ast}\;is\;0.79<{\phi}<1.9$. However, it was difficult to predict the equivalence ratio in partially premixed flames using this system for ${\phi}>2.38$, (3) the minimum NOX emission index (EINOx) is obtained for a equivalence ratio of 3.19 in the intermediate flames.

An Experimental Study on Correlation of Compression Ignition Condition at Cold Start with Hydrogen HCCI Engine (냉시동시 압축착화 조건의 상관관계에 관한 수소 HCCI 기관의 실험적 연구)

  • Lee, Kwangju;Lee, Jonggoo;Ahn, Byunghoh;Lee, Jongtai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.628-633
    • /
    • 2012
  • It was found that the pure hydrogen-air pre-mixture was self-ignited at a high compression ratio without any assisting method in room temperature, thus refuting the preconception that compression ignition of hydrogen engine was impossible. Therefore, in order to analyze the correlation of compression ignition condition at cold start with hydrogen HCCI engine clearly, the possibility of compression igniting compression ratio is investigated with the change of equivalence ratio and engine speed, experimentally. As the results, it is confirmed that the possibility of compression-igniting compression ratio at cold start was decreased by increasing equivalence ratio due to decreasing auto-ignition temperature. In addition, it is grasped that the possibility of compression-igniting compression ratio at cold start is decreased around 14.9% by increasing engine speed at same supply energy.

The Performance Evaluation of a Gas Turbine Combustor (가스터빈 연소기의 성능평가)

  • Ahn, Kook-Young;Kim, Han-Seok;Ahn, Jin-Hyuk;Pae, Hyoung-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1294-1299
    • /
    • 2000
  • The combustion characteristics have been investigated to develop the 50 kW-class gas turbine combustor. The combustor design program was developed and applied to design this combustor. The combustion air which has the temperature of 45, 200, $300^{\circ}C$ were supplied to combustor for elucidating the effect of inlet air temperature on CO, NOx emissions and flame temperature. The exit temperature and NO were increased and CO was decreased with increasing inlet air temperature. Also, the effect of equivalence ratio was considered to verify the combustor performance. The emissions of CO and NO with inlet air temperature can be analyzed qualitatively by measuring the temperature inside the combustor. The combustion performance with fuel schedule was evaluated to get the informations of the starting and part loading process of gas turbine. The combustion was stable above the equivalence ratio of 0.18. The pattern factor which is the important parameter of combustor performance was satisfied with the design criterion. Consequently the combustor was proved to meet the performance goal required for the target gas turbine system.

A Basic Analysis of Performance of Turbo CI Engine based on Stirling Cycle (스털링 사이클을 기본으로 하는 과급 CI 엔진의 기초 성능 분석)

  • 배종욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.76-85
    • /
    • 2000
  • Stirling cycle was actualized as so called ‘hot air engine’. It has been focused again lately as one of measures for exhaust gas emission problem, but as small power engine because of its method of heat addition. Recently marine power plants commenced to meet a stringent environmental restrictions by international convention, Marpol so that diesel engines as main and auxiliarly power plants are urged to be reformed to reduce NOx emission. Author devised a compression ignition engine as a large marine power plants combined with turbo charger based on stirling cycle, and analyzed the performance by means of basic thermodynamic calculation. Analyzed in this paper, were theoretical efficiency, mean effective pressure, required equivalence ratio, gas turbine power ratio, maximum pressure, states of turbo-charger inlet gas and exhaust gas, manifesting that the engine could be proposed as one of the future power plants of marine use.

  • PDF

Measurement of Laminar Flame Speed of Syngas(H2/CO)/Air Premixed Flame using the Bunsen Burner Method (분젠 버너법을 이용한 합성가스(H2/CO)/공기 예혼합화염의 층류 연소속도 측정)

  • Jeong, Byeonggyu;Lee, Kee-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.181-183
    • /
    • 2012
  • Syngas laminar flame speed measurements were carried out at atmospheric pressure and ambient temperature using the Bunsen flame configuration with nozzle burner as a fundamental study on flame stability of syngas. Representative syngas mixture compositions ($H_2:CO$) such as 25:75%, 50:50% and 70:25% and equivalence ratios from 0.5 to 1.4 were investigated. The measured laminar flame speeds were in good agreement with the previous numerical data as well as experimental data available in the literatures over a wide range of equivalence ratio tested. It was reconfirmed that the laminar flame speed gradually increased with the increase in $H_2$ content in a fuel mixture. In particular, the significant increasing rate of flame speed was observed with the increase in equivalence ratio.

  • PDF

MILD Combustion Characteristics with Inlet Air Velocity in a Conical Combustor (원추형 연소로에서 공기 유속에 따른 MILD 연소특성)

  • Kim, Tae-Kwon;Ha, Ji-Soo;Jo, A-Ron
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.774-779
    • /
    • 2012
  • MILD (Moderate and Intense Low Oxygen Dilution) combustion is a technology that uses the recirculation of combustion gas to increase thermal efficiency not only by keeping down the concentration of Nitric Oxides and temperature but also by uniformizing the internal temperature of the combustion furnace. This study is a trial to obtain MILD combustion characteristics by adjusting the equivalence ratio with the air flow rate in the conical combustor while keeping the fuel flow rate and measuring the exhaust gas of the combustion furnace.