• Title/Summary/Keyword: Equipment control

Search Result 4,115, Processing Time 0.037 seconds

The Utilization Pattern of a Rural Health Subcenter among Suburban Farmhouse Members (일 도시근교 농가구원의 보건지소 이용양상)

  • Sohn, Seok-Joon;Kwon, Sun-Seok;Kim, Sang-Won;Byun, Ju-Nam;Nam, Hae-Sung;Son, Myung-Ho
    • Journal of agricultural medicine and community health
    • /
    • v.24 no.1
    • /
    • pp.65-77
    • /
    • 1999
  • In order to estimate the utilization pattern of a rural health subcenter, and to identify the recognition for it among the farmhouse members in a suburban area, a questionnaire survey was carried out for objects of 696 population. The results observed were as follows: The annual utilization rate of rural health subcenter for a basic health service unit was 25.0 per 100 persons, and annual mean visiting times was 0.22 times. And the most frequent disease by annual health subcenter utilization illness was musculoskeletal disease(30.6%), and the next was respiratory disease(14.1%), gastrointestinal disease(13.9%) by order. Favorite reason for community health subcenter utilization were near distance from living place(49.6%), lower disease severity(18.9%) and lower medical cost(18.1%) by order. But disfavoring reasons for it were absence of specialist(20.2%), non effective treatment(19.2%) and insufficient equipment(14.7%) by order. And insufficient items about community health subcenter utilization were restriction of treatment limit(40.7%), lower reliance(22.5%) and difficulty in traffic(13.4%) by order. The results of logistic regression analysis suggested that statistically significant factors in health subcenter utilization was educational level. The desirable works for the health subcenter in a suburban area were disease control of elderly and disease preventing service. These results suggested that to increase the utilization of rural health subcenter in a suburban area and to promote the accessibility of rural residents to primary health care, there must be considered public relation about health subcenter, improvement of medical quality and change of priority about health subcenter's works.

  • PDF

Regulations of Launch Services and Management of Satellites in the Japanese Space Activities Act (인공위성의 발사 및 관리에 관한 규제 논점 - 2016년 일본 '우주활동법'을 중심으로 -)

  • Kim, Young-Ju
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.35 no.3
    • /
    • pp.151-208
    • /
    • 2020
  • Japan's two outer space-related laws were promulgated on November 16, 2016. There are the Act on Launching of Spacecraft, etc. and Control of Spacecraft (Act No. 76 of 2016, Space Activities Act) and the Act on Securing Proper Handling of Satellite Remote Sensing Records (Act No.77 of 2016, Remote Sensing Records Act). Japan's Space Activities Act states that a person who launches a satellite from the territory of Japan, or from a ship or airplane registered in Japan, must obtain permission from the Prime Minister prior to the launch. To obtain the permission, the person must have a certificate for a rocket design and for radio equipment at a launching facility. In addition, the ability to launch a rocket safely and the purpose for the satellite launch must be evaluated. Managing a satellite from Japan also requires permission from the government. A person who launches a rocket must have insurance for any potential damage arising from accidents, and the government is to supplement the potential compensation to allow for damage that cannot be covered by private insurance. The purpose of this paper reviews regulations of launch services and management of satellites in the Japan's Space Activities Act. It also offers some implications and suggestions for regulations of launching of spacecraft and management or operation of satellites.

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

A Study on the Competencies of Automotive Professional Engineers in Korea (자동차 신제품개발 관련 차량기술사의 전문적 업무역량 분석)

  • Kim, Joo-Young;Lim, Se-Yung
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.192-217
    • /
    • 2008
  • This paper investigated the perceived criticalities and patterns of Korean Professional Engineer's competency regarding the working activities of automative product development, manufacturing, etc by using questionnaires responded to the survey which were applied to the automotive professors, experts and professional engineers (vocational parties) by e/mail, etc. This research investigated the following questions: First, what are the characteristic patterns, relevancy and perceived criticalities of Korean Professional Engineer's competencies? Second, What are the ranked priority of the Korean Professional Engineers' competencies? Are there any differency for each item, sub group of job, intelectual criterior of the competencies between relevancy and perceived criticalities according to the types of vocational parties, etc.? Accoring to the results; first, Professor group showed highest points among 3 groups per each item of the competencies by vocational parties Second, Chassis design group ranked top position among the 8 sub groups by vocational parties and, third, Problem Solving Knowledge ranked highest points than any others. Korean Professional Engineers are found to be positioned as key members, leaders and managers on surveying market, product planning, designing product & components, developing component parts, establishing shop with production equipment, managing quality control & material handling, organizing relevant meetings, developing human resources by training and learning, to back up finance with law matters, cooperating with concerned parties to achieve organizational goals, and to coordinate projects. etc, identifying ethical issues and business skills in order to survive and win to be competitive in various kinds of the automotive industry battle fields.

Survey on sanitary knowledge level and degree of HACCP practice in culinary staff employed in elementary, middle, and high schools in Chungnam province (충남지역 초.중.고 학교급식 조리원의 위생지식 및 HACCP 수행도 조사)

  • Lee, Young Joong;Kim, Sun Hyo
    • Journal of Nutrition and Health
    • /
    • v.47 no.4
    • /
    • pp.300-312
    • /
    • 2014
  • Purpose: This study was performed to examine the sanitary knowledge level and degree of HACCP (hazard analysis critical control point) practice in school culinary staff in order to provide basic information for improving hygiene of school meals. Methods: Exactly 305 culinary staff members were selected from elementary, middle, and high schools in 14 cities and rural areas, including whole administrative districts in Chungnam province. Surveyed schools were selected by convenience sampling, and one subject was selected randomly from each school. Surveys were taken by self-administered questionnaires developed by researchers and questionnaire were distributed and collected by postal mail. Results: Sanitary education administered by school dietitians to culinary staff was more frequent and longer in elementary schools, followed by middle and high schools (p < 0.001). Sanitary knowledge level and degree of HACCP practice, except for a few CCP or CP of culinary staff, were highest in elementary schools and middle school followed by high schools (p < 0.05), respectively. School class was negatively correlated with sanitary knowledge level of culinary staff (p < 0.01), and frequency of sanitary education was positively correlated with sanitary knowledge level of culinary staff (p < 0.01). Sanitary knowledge level of culinary staff was positively correlated with degree of HACCP practice (p < 0.01). School class, daily frequency of meal service, work experience, rice washing machine, and total score of sanitary knowledge were significant variables influencing degree of HACCP practice in culinary staff. Conclusion: The above results show that the following points should be considered to improve hygiene of school meals. Sanitary education should be administered more frequently by school dietitians to culinary staff, especially to those in high schools, which showed the lowest sanitary knowledge level and degree of HACCP practice. In addition, facilities and equipment required for HACCP practice should be supported in small-sized elementary schools.

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application (Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가)

  • Kim, Jung-Soo;Kim, Byung-Jin;Kim, Jin-Eui;Woo, Jae-Ryong;Kim, Hyun-Joo;Shin, Heui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Purpose: The image processing method due to the algorism which is various portion nuclear medical image decision is important it makes holds. The purpose of this study is it applies hereupon new image processing method SIEMENS (made by Pixon co.) Onco. flash processing reconstruction and the comparison which use the image control technique of existing the clinical usefulness it analyzes with it evaluates. Materials & Methods: 1. Whole body bone scan-scan speed 20 cm/min, 30 cm/min & 40 cm/min blinding test 2. Bone static spot scan-regional view 200 kcts, 400 kcts for chest, pelvis, foot blinding test 3. 4 quadrant-bar phantom-20000 kcts visual evaluation 4. LSF-FWHM resolution comparison ananysis. Results: 1. Raw data (20 cm/min) & processing data (30 cm/min)-similar level image quality 2. Low count static image-image quality clearly improved at visual evaluation result. 3. Visual evaluation by quadrant bar phantom-rising image quality level 4. Resolution comparison evaluation (FWHM)-same difference from resolution comparison evaluation Conclusion: The study which applies a new method Onco. flash processing reconstruction, it will be able to confirm the image quality improvement which until high level is clearer the case which applies the method of existing better than. The new reconstruction improves the resolution & reduces the noise. This enhances the diagnostic capabilities of such imagery for radiologists and physicians and allows a reduction in radiation dosage for the same image quality. Like this fact, rising of equipment availability & shortening the patient waiting move & from viewpoint of the active defense against radiation currently becomes feed with the fact that it will be the useful result propriety which is sufficient in clinical NM.

  • PDF