• Title/Summary/Keyword: Equipment control

Search Result 4,123, Processing Time 0.037 seconds

Importance of Education Contents and Competencies on Home Care Nursing of the Hospital and Public Health Nurses in Korea (임상간호사와 보건간호사가 지각한 가정간호 교육내용의 중요도 및 업무수행능력)

  • Yu, Sook-Ja;Kim, Soon-Lae;Baek, Hee-Chong;Lee, Jong-Eun
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.7 no.1
    • /
    • pp.5-14
    • /
    • 2000
  • This study was conducted during the time period of September 1997 to February 1999. in order to provide data concerning important facets of horne care nursing and the degree to which practicing hospital and public health nurses believe themselves to be competent in each area. The study subjects consisted of 610 hospital nurses, 158 public health nurses and 21 other nurses from Seoul and the province of Kyunggi. Korea. Data was collected through self-reporting questionnaires which was used by Kim et al.(1999) to evaluate the status of home health nursing and the varying ideas of self-competence that practicing nurses have. The results of the study were as follows: 1) The mean scores of perceived important components and competencies on home health nursing measured on the Likert 4 point scale were $3.15{\pm}0.36$ for importance. and $2.56{\pm}0.36$ for competency. Of the four categories regarding nursing services, the 'Nursing skill' factor had the highest importance and competency. 2) There were significantly higher scores for hospital nurses' importance components and competencies of home care nursing as compared to those scores for public health nurses. 3) The significant factors of the importance component of home care nursing listed in order of priority were 'general infection control', 'bed sore care skill', 'rehabilitation care', 'keeping maintenance of the client's confidentiality', 'malpractice', 'diabetes patient care', 'ability for problem solving' respectively. In contrast, of low priority in the importance components of home care nursing were 'referring nursing as a job to others'. 'record keeping', 'family dynamics', 'medical equipment', 'economic problems', 'environmental assessment', 'suture removal', 'multidisciplinary coordination' respectively. 4) The high priority of the degree to which practicing nurses believe themselves to be competent in home health nursing were the 'blood sugar test', 'enema skill', 'injection skill', 'skin care', 'bed sore care skill', etc. In contrast, lower competence for home care nursing as perceived by nurses were 'AIDS care', 'family violence care', 'substance abuse care', 'mental health care' respectively.

  • PDF

Study on the Distributions of VOCs, Aldehydes, PAHs Concentration in Seoul Metropolitan Area (수도권 지역에서 환경대기 중 유해대기오염물질 (VOCs, Aldehydes, PAHs) 농도분포 특성 연구)

  • Han, Jin-Seok;Lee, Min-Do;Lim, Young-Jae;Lee, Sang-Uk;Kim, Young-Mi;Kong, Boo-Joo;An, Jun-Young;Hong, You-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.574-589
    • /
    • 2006
  • Although concentrations of hazardous air pollutants(HAPs) are very low in the atmosphere, a growing attention has been paid on such compounds due to their high toxicity and bioaccumulation potentials into human body. In order to control and manage the amount of these materials in ambient air, it is necessary to construct monitoring system of them and to know the current concentration level of HAPs above all. In this work, a wide range of HAPs has been measured in metropolitan area to recognize the present state of HAPs in this area. The measured concentration of VOCs was higher in order of Jeonnongdong, Jeongdong, and Yangsuri. The regional difference of VOCs concentration was also highest in spring. Its total VOCs was ranged from $15.17{\sim}41.45$ ppb. Benzene $0.43{\sim}2.32$ ppb showed similar concentration level with the result of previous researches in Seoul. This value is a little higher than the average concentration 0.92 ppb for national ambient air quality standards in Japan. The concentration of aldehydes in this study was lower than those of other researches. Previous works in Seoul metropolitan area showed that the concentration of formaldehyde and acetaldehyde were higher than 5 ppb. The concentration of gaseous and particulate PAHs was high in order of winter, spring, and summer More than 90% of PAHs with low molecular weight such as 2-rings and 3-rings PAHs existed in gas phase. On the other hands, PAHs with high molecular weight more than 5-rings PAHs almost existed in particulate. In spring, the concentration of gaseous PAHs was 24.38 $ng/m^3$ in Jeongdong. Among the particulate PAHs, the concentrations of Naphthalene, Benzo(b)fluoranthene, and Benzo(g, h, i)perylene were higher than others. Especially, the concentration of Benzo(a)pyrene, a important carcinogenic pollutant, was highest in winter 0.5 $ng/m^3$ and ranged from 0.03 to 0.3 $ng/m^3$ in spring and summer, which is lower than the monitoring result in 90's. These components were mainly originated from the vehicle exhaust or heating equipment use.

A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads (상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;Lee, Jaewon;Kim, Taejin;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2017
  • The purpose of this study is to investigate the effect of vertical and horizontal refraction on the lower part of the power supply and control system of various facilities and machinery that use electricity, so that the power distribution system, which is an important electric facility installed in buildings and public facilities, Type earthquake resistant pads to protect the substructure and prevent short-circuiting on the upper part of the system. The GR-63-CORE (Scale 8.3 class) It is earthquake disaster prevention and disaster prevention technology that satisfies seismic performance. As a research result, it is possible to protect the electricity and communication infrastructure, which can contribute to shortening the time for recovering the electric facilities to the normal state in case of an earthquake, and preventing the fire caused by the destruction of the electricity supply facility in case of an earthquake. As a result, it is possible to minimize the spread of fire that occurs when a large-scale earthquake occurs and to minimize the damage of people and damage to property, and it can contribute to the securing of electric infrastructure that enables citizens to quickly recover to daily life even after suffering a major earthquake. In addition, the technology can be applied to ensure the seismic resistance of the equipment in the communication and computer room, and it can be applied to various fields where the facility function can be stopped due to the shaking of the earthquake base.

A Survey on the Sanitary Management in Food Service Institutions (집단급식소의 위생관리에 대한 실태 조사)

  • Soh, Gowan-Soon;Kim, Yong-Suk;Shin, Dong-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.1
    • /
    • pp.63-75
    • /
    • 2007
  • A survey on sanitary management at 98 food service institutions located in Jeollabuk-Do were conducted. Food service institutions included 13 hospitals, 38 schools, 40 enterprises, and 7 others. The sterilization in boiling water was used for disinfection of tableware, spoon and chopsticks, and dish towel. Cooking kit, refrigerator, chopping board, and knife were sterilized with disinfectant. Frequency of sanitary training program on employees was 56.1% for 1 time/month, 12.2% for 2-3 times/month, and 11.3% for 1 time/week. Preparing ratio of defrosting, warehouse and rest room, and washing and sterilization diary were 73.8, 60.5, and 54.5%, respectively. However, checking ratio of environments (9.5%), personal sanitation (10.8%), and sanitary training program diary(8.4%) were low. Major obstacle factors on the introduction of Hazard analysis critical control point (HACCP) system into food service institutions were lack of equipment and facilities (54.1%) and lack of understanding and data on HACCP system (17.3%). Therefore, in order to reduce the outbreak of food-borne diseases increasing frequency, we estimated that the introduction of sanitary management system and the conversion of dietician' perception on sanitary managements in food service institutions were needed.

Studies on the Rapid Plasma Reagin(RPR) Card Test for the Diagnosis of Syphilis (매독진단(梅毒診斷)을 위(爲)한 신속(迅速)한 혈장항체검사법(血漿抗體檢査法)에 관(關)한 연구(硏究))

  • Kim, Joo-Deuk;Lew, Joon;Kim, Hyun-Joo
    • The Journal of the Korean Society for Microbiology
    • /
    • v.3 no.1
    • /
    • pp.15-23
    • /
    • 1968
  • For the effective control of Syphilis, many investigators have developed a more rapid, simple and economical screening serological test which is adequately sensitive and specific. To fulfill the requirements of a more rapid serologic test for syphlis, a substitute for the conventional serum specimen was needed since considerable time and labor are involved in the processing of blood to serum. Burdon suggested the use of plasma in the serologic tests for syphilis as a substitute for serum. He noticed that plasma was more sensitive than serum in the Kline and Kahn tests, and attributed this to the presence of more antibody-like substance, "reagin" in plasma than in serum. However, to make plasma sufficiently sensitive, it was necessary to inactivate plasma by heating at a temperature of $56^{\circ}C$ for about 30 minutes. Heating of plasma resulted in the precipitation of fibrinogen which made centrifugation necessary to obtain dear plasma. Since the chief disadvantage to the use of unheated plasma(or serum) was a reduction in sensitivity of results-which probably was due to a labile factor such as complement-Portnoy et al began to consider rapid chemical methods of inactivation of plasma(or serum). They experienced that choline chloirde was shown to be anticomplementary which suggested its use as an inactivating agent for unheated plasma(or serum). In 1959 Portnoy et al reported the Rapid Plasma Reagin(RPR) Test for syphilis which is a more rapid, economical and simple. But still this test has many disadvantages as a rapid performing, field and office procedure, because it requires the usual laboratory equipments such as centrifuge, rotating machine, microscope etc. To substitute these disadvantages of the RPR test, in 1962, Portnoy et al developed the Rapid Plasma Reagin(RPR) card test for syphilis, which has the following advantages: a) Simplicity and rapidity of performance, b) Requires no laboratory equipments, c) Stable antigen suspension, d) Adequate sensitivity and specificity. This RPR card test can be used as a rapidly performing and screening test in field investigation, outpatient clinics, small laboratories and hospitals doing limited syphilis serology, and predonor in blood bank. Private clinic which has limited laboratory equipment and technic for syphilis serology can also use this RPR card test as a tool in the rapid diagnosis of syphilis. It was thought that this RPR card test is a useful tool in Korea for private physician and mass survey for syphilis diagnosis. But Portnoy patented the reagents needed for the performing the RPR card test. Therefore authors developed newly the reagents and according to Portnoy's method evaluated the newly developed. RPR card test compared with the VDRL, Kolmer CF, and RPCF tests. The RPR card and VDRL tests were performed plasma and serum from the total 1,132 cases. Among these 1,131 cases, 521 were syphilis suspected laboratory specimens, and 611 were syphilis unsuspected healthy young men. After screening with these two tests, the RPR card and VDRL tests, reactive specimens to the above one or both tests were retested by the Kolmer CF and RPCF tests.

  • PDF

Real Time Safety Management Framework at Construction Site based on Smart Mobile (스마트모바일 기반의 실시간 현장안전관리 프레임워크)

  • Park, Moonseo;Kim, Euijun;Lee, Hyun-Soo;Lee, Kwangpyo;Suh, Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.3-14
    • /
    • 2013
  • Recently, as the size of construction projects is getting bigger and higher, construction disasters have been being serious such as death, also it is hard to manage efficiently since there are plenty of informations about safety management. Thus on the spot & real time safety management is required and one of the ways to support these needs, conjunction with Information Technology(IT) has been being noticed. Accordingly, Personal Digital Assistant(PDA), Palmtop Computer and Tablet Personal Computer and so on have been adopted. However another inefficient sides are showed up such as limitation of equipment(weight, inconvenience of control and others). Meanwhile, exchanging and processing data are improved at wide area due to advance of mobile communication and introduction of smart mobile, which is a simple and convenient, is a proven at many aspects. In this research, to support effective safety management, the framework is realized in connection with smart mobile with finding the problems of safety management and deriving demands. Two smart mobile applications, which are Safety Management application and Safety Guideline application, enable that safety management in real time, less re-work and using safety information.

Bacterial Contamination of Dental Unit Water Systems in a Student Clinical Simulation Laboratory of College of Dentistry (치과대학 임상 시뮬레이션 실습실 치과용 유니트 수계의 세균 오염도 조사)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.232-237
    • /
    • 2015
  • The water supplied from dental unit water systems (DUWS) in dentistry may be heavily contaminated with bacteria and thus may be a potential source of infection for both practice staff and patients. The aim of this study was to evaluate the level of heterotrophic bacteria and to confirm the presence of opportunistic pathogens from DUWS in student clinical simulation laboratory of college of dentistry. Water samples were collected from 36 ultrasonic scalers in student clinical simulation laboratory. The levels of heterotrophic bacteria in water samples were quantified by counting colony forming units (CFUs) on R2A agar media. In addition, opportunistic pathogens were detected by using the polymerase chain reaction (PCR) method. The mean CFUs were 16,095 CFU/ml for water samples and all of water samples exceeded current American Dental Association recommendations of 200 CFU/ml. Pseudomonas species and non-tuberculous Mycobacterium species were detected in the one sample and two samples, respectively, among the 36 water samples by the PCR with specific primers for these bacteria. Our study indicated that DUWS in student clinical simulation laboratory can cause potential infection in students and participants. This study suggested the dental unit water line management and wearing personal protective equipment in student clinical simulation laboratory will be needed to reduce bacterial contamination.

Study of the Risk of Ignition due to Internal Combustion Engines in Areas with Potentially Explosive Gas Atmospheres (잠재적 폭발위험장소에서 내연기관에 의한 점화 위험성에 관한 연구)

  • Kim, Yun Seok;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.1-8
    • /
    • 2016
  • Safety management in hazardous areas with potentially explosive gas atmospheres (here in after referred to as hazardous areas) in large scale facilities dealing with combustible or flammable materials at home and abroad is very important (significant) for the coexistence of the company and local society based on business continuity management (BCM) and reliance. For the safety management in hazardous areas, two systems are mainly used: (1) the control system for the prevention of combustible or flammable substances and (2) the explosion proof system for the elimination of ignition sources when flammable gases are leaked to inhibit the transition to fire or explosion accidents. While technology and regulations on explosion proof facilities or devices for electrical ignition sources are well developed and defined, those for thermal ignition sources need to be more developed and established. In this study, the internal combustion engine in hazardous areas was investigated to determine the risk of ignition. For this purpose, document searches were conducted on the relevant international standards and accidents cases and risk analysis reports. In addition, this study assessed the application cases of the diesel engine's safety equipment, such as spark arresters regarding the site of process safety management (PSM) system in central Korea. To practically apply these results to the hydrocarbon industry, the safety management method for explosion prevention in hazardous areas was provided by risk identification for ignition sources of internal combustion engines, such as diesel engines.

A Study on the Effectiveness Verification of Hydrological Cycle of Pervious Pavement using LID Simulator (LID 효율성 검증기기를 이용한 투수성 블록의 수문순환 효율성 검증에 관한 연구)

  • Kim, Mi Eun;Jang, Young Su;Nam, Chil Ho;Shin, Hyun Suk
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.321-330
    • /
    • 2015
  • In recent, the impacts of urbanization on hydrology and water quality can be minimized with the use of Low Impact Development (LID) practices in urban areas. But, there are no ways to verify or to show the quantitative effectiveness with LID practices. This study designed and developed to perform experiments in natural or artificial representation of hydrological cycle, which is called rainfall-runoff simulator to be able to quantify factors in hydrological system. This simulator was applied to a pervious pavement block. The study conducted analysis of effectiveness for a pervious pavement block by comparing the results with a general pavement block. The result from the pervious pavement block showed remarkably reduction effect on surface runoff with increase of rainfall intensity and more duration time. Also, the simulator was possible to control no surface runoff by a rainfall intensity at 50 mm/hr for an hour. The research indicated possibility and effectiveness for LID practices. This might be widely available to apply to LID practices verification. Therefore, the study is possible to make use of practical standards on fundamental studies.

Practical Usage of Low-Temperature Metal Catalyst for the Destruction of Volatile Organic Compounds (VOCs) (휘발성 유기화합물(VOCs) 제거를 위한 저온금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.397-405
    • /
    • 2012
  • In this study, performance evaluation of newly developed technology for the economical and safe removal of volatile organic compounds (VOCs) coming out from electronic devices washing operation and offensive odor induction materials was made. Metal oxidization catalyst has shown 50% of removal efficiency at the temperature of $220^{\circ}C$. Composite metal oxidization catalyst applied in this study has shown that the actual catalysis has started at the temperature of $100^{\circ}C$. Comprehensive analysis on the catalyst property using Mn-Cu metal oxidization catalyst in the pilot-scale unit was made and the removal efficiency was variable with temperature and space velocity. Full-scale unit developed based on the pilot-scale unit operation has shown 95% of removal efficiency at the temperature of $160^{\circ}C$. Optimum elimination effective rates for the space velocity was found to be $6,000hr^{-1}$. The most appropriate processing treatment range for the inflow concentration of VOCs was between 200 ppm to 4,000 ppm. Catalyst control temperature showed high destruction efficiency at $150{\sim}200^{\circ}C$ degrees Celsius in 90~99%. External heat source was not necessary due to the self-heat reaction incase of VOCs inflow concentration is more than 1,000 ppm. Equipment and fuel costs compared to the conventional RTO/RCO method can be reduced by 50% and 75% respectively. And it was checked when there was poisoning for sulfide and acid gas.