• Title/Summary/Keyword: Equipment Noise

Search Result 989, Processing Time 0.038 seconds

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

A Study on the Status of Work Environment in the Manufacturing with Less Than Five Workers in Gimhae Area (김해지역 5인 미만 제조업 사업장의 작업환경실태)

  • Lee, Kyung-Yeul;Moon, Deog-Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.131-144
    • /
    • 2006
  • For the purpose of preparing the fundamental data on working environment of small scale manufacturing industries and preventing the occupational diseases of workers in these industries, authors surveyed the status of working environment to several chemical substances and physical agents by types of industry and types of process in the small scale manufacturing industries with less than five workers in Gimhae including 235 workplaces, 14 types of industry and 25 types of process from January 2002 to December 2004. This measurement method was work environment measurement method (established in Ministry of Labor, Korea), analytical methods (2nd Ed.) of Occupational Safety and Health Administration (OSHA) and manual of analytical methods (4th Ed.) of National Institute for Occupational Safety and Health (NIOSH) and collected data was analyzed by using SPSS 10.0 for windows, the results were as follows: 1. Noise generated in 14 types of industry and 22 types of process. an actual level of mean exposure (90.7 dB(A)) exceeded threshold limit values (TLVs) in manufacture of other transport equipment. An actual level of mean exposure (90.2dB) exceeded TLVs in the process of wire-drawing and 90.4dB in the process of wire-stranding. 2. Dusts of type I, II, III were generated in 9 types of industry and 8 types of process. Its mean concentration did not exceed TLVs. 3. Heavy metals (Pb, Mn, Cr, Ni) were generated in 7 types of industry and 7 types of process. Its mean concentration did not exceed TLVs. 4. 16 kinds of organic solvents were generated in 11 types of industry and 6 types of process. Its mean concentration did not exceed TLVs. As the above results, chemical substances and physical agents were generated in the several different types of industry and process of the manufacturing industry with less than five workers, and only mean level of noise was exceeded TLVs. In case of exceeding threshold limit values, improvement of work environment is actively needed, and work environment management should be performed continuously for prevention of an occupational diseases and work related diseases.

Power Control Scheme for Effective Serving Cell Selection in Relay Environment of 3GPP LTE-Advanced System (3GPP LTE-Advanced 시스템의 Relay 환경에서 효율적인 Serving Cell 선택을 위한 Power Control 기법)

  • Min, Young-Il;Jang, Jun-Hee;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3A
    • /
    • pp.215-222
    • /
    • 2011
  • In this paper, we propose a power control scheme for effective serving cell selection in Relay environment of 3GPP (3rd Generation Partnership Project) LTE (Long Tenn Evolution)-Advanced system. A conventional serving cell selection scheme which does not use channel states of backhaul link has a problem that this scheme does not select serving cell supporting maximum throughput. Also, conventional proposed serving cell selection schemes that eNB or RN transmits channel states of backhaul link have problems that conventional schemes need to additional data transmission, serving cell selection process complexity is increased because UE considers channel states of backhaul link, and received signal is degraded because strong interference which is transmission signal from RN. Therefore, for solve these problems, we propose power control scheme that RN control transmission power according to received SINR (Signal to Interference plus Noise Ratio) of backhaul link. By extensive computer simulation, we verify that the power control Relay scheme is attractive and suitable for the Relay environment.

A Cell Selection Technique Considering MIMO Precoding (MIMO 프리코딩을 고려한 셀 탐색 기법)

  • Kim, Han Seong;Hong, Tae Howan;Cho, Yong Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.12
    • /
    • pp.1076-1084
    • /
    • 2012
  • In the CS/CB(Coordinated Scheduling/Beamforming) scheme, the cell edge user throughput is increased by selecting MIMO (Multiple Input Multiple Output) precoders which can minimize the interferences from adjacent base stations (BSs). However, in current LTE(Long Term Evolution) systems, the serving cell is selected in the initialization stage by using the synchronization signals and cell specific reference signals transmitted by adjacent BSs with a single antenna. The selected BS in the initialization stage may not be the best one since the MIMO precoding gain has not been considered in the cell selection stage. In this paper, a new cell selection technique is proposed for LTE systems with MIMO precoder by taking into account the effect of the precoder in the initialization stage. The proposed technique enables a user equipment (UE) in the cell boundary to select the serving BS by using the information (channel rank, effective channel capacity, and effective SINR(Signal to Interference plus Noise Ratio)) acquired from cell specific reference signals of candidate BSs. It is verified by computer simulation that the proposed technique can increase the channel capacity significantly in the multi-cell environments, compared with the conventional CS/CB scheme.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Optimization of Tube Voltage according to Patient's Body Type during Limb examination in Digital X-ray Equipment (디지털 엑스선 장비의 사지 검사 시 환자 체형에 따른 관전압 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.379-385
    • /
    • 2017
  • This study identifies the optimal tube voltages depending on the changes in the patient's body type for limb tests using a digital radiography (DR) system. For the upper-limp test, the dose area product (DAP) was fixed at $5.06dGy{\ast} cm^2$, and for the lower-limb test, the DAP was fixed at $5.04dGy{\ast} cm^2$. Afterwards, the tube voltage was changed to four different stages and the images were taken three times at each stage. The thickness of the limbs was increased by 10 mm to 30 mm to change in the patient's body type. For a quantitative evaluation, Image J was used to calculate the contrast to noise ratio (CNR) and signal to noise ratio (SNR) among the four groups, according to the tube voltage. For statistical testing, the statistically significant differences were analyzed through the Kruskal-Wallis test at a 95% confidence level. For the qualitative analysis of the images, the pre-determined items were evaluated based on a 5-point Likert scale. In both upper-limb and lower-limb tests, the more the tube voltage increased, the more the CNR and SNR of the images decreased. The test on the changes depending on the patient's body shape showed that the more the thickness increased, the more the CNR and SNR decreased. In the qualitative evaluation on the upper limbs, the more the tube voltage increased, the more score increased to 4.6 at the maximum of 55kV and 3.6 at 40kV, respectively. The mean score for the lower limbs was 4.4, regardless of the tube voltage. The more either the upper or lower limbs got thicker, the more the score generally decreased. The score of the upper limps sharply dropped at 40kV, whereas that of the lower limps sharply dropped at 50kV. For patients with a standard thickness, the optimized images can be obtained when taken at 45kV for the upper limbs, and at 50kV for the lower limbs. However, when the thickness of the patient's limbs increases, it is best to set the tube voltage at 50 kV for the upper limbs and at 55 kV for the lower limbs.

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Effect of Interference Mitigation Technique and Performance Analysis for Small Cell in Homogeneous Networks (동종네트워크 상에서 셀 소형화 간섭 완화 기법 및 성능 분석)

  • Jang, Ye-Ok;Cho, Eun-Hyung;Hong, Een-Kee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.937-945
    • /
    • 2014
  • As various services requiring high data rate are supported by introducing LTE/LTE-adv., mobile traffic increases rapidly. To cope with the continuous growth of traffic demand, small cell technology is considered as one of the most promising one. Small cell can increase system capacity by increasing the number of base stations with reduced cell radius. In this paper, we analyze the effect of cell densification with small cells in terms of SINR and average UE throughput considering cell split and the number of UE per unit area. As the cell becomes smaller, SINR degradation arises from high ICI(Inter Cell Interference) and we evaluate the effect of interference mitigation scheme in small cell environment where the proper interference mitigation technique is applied.

Load Modeling based on System Identification with Kalman Filtering of Electrical Energy Consumption of Residential Air-Conditioning

  • Patcharaprakiti, Nopporn;Tripak, Kasem;Saelao, Jeerawan
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • This paper is proposed mathematical load modelling based on system identification approach of energy consumption of residential air conditioning. Due to air conditioning is one of the significant equipment which consumes high energy and cause the peak load of power system especially in the summer time. The demand response is one of the solutions to decrease the load consumption and cutting peak load to avoid the reservation of power supply from power plant. In order to operate this solution, mathematical modelling of air conditioning which explains the behaviour is essential tool. The four type of linear model is selected for explanation the behaviour of this system. In order to obtain model, the experimental setup are performed by collecting input and output data every minute of 9,385 BTU/h air-conditioning split type with $25^{\circ}C$ thermostat setting of one sample house. The input data are composed of solar radiation ($W/m^2$) and ambient temperature ($^{\circ}C$). The output data are power and energy consumption of air conditioning. Both data are divided into two groups follow as training data and validation data for getting the exact model. The model is also verified with the other similar type of air condition by feed solar radiation and ambient temperature input data and compare the output energy consumption data. The best model in term of accuracy and model order is output error model with 70.78% accuracy and $17^{th}$ order. The model order reduction technique is used to reduce order of model to seven order for less complexity, then Kalman filtering technique is applied for remove white Gaussian noise for improve accuracy of model to be 72.66%. The obtained model can be also used for electrical load forecasting and designs the optimal size of renewable energy such photovoltaic system for supply the air conditioning.