• Title/Summary/Keyword: Equilibrium profile

Search Result 103, Processing Time 0.028 seconds

[ N2H+ ] OBSERVATIONS OF MOLECULAR CLOUD CORES IN TAURUS

  • TATEMATSU KEN'ICHI
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.279-282
    • /
    • 2005
  • We report the millimeter-wave radio observations of molecular cloud cores in Taurus. The observed line is the $N_2H^+$ emission at 93 GHz, which is known to be less affected by molecular depletion. We have compared starless (IRAS-less) cores with star-forming cores. We found that there is no large difference between starless and star-forming cores, in core radius, linewidth, core mass, and radial intensity profile. Our result is in contrast with the result obtained by using a popular molecular line, in which starless cores are larger and less condensed. We suggest that different results mainly come from whether the employed molecular line is affected by depletion or not. We made a virial analysis, and found that both starless and star-forming cores are not far from the critical equilibrium state, in Taurus. Together with the fact that Taurus cores are almost thermally supported, we conclude that starless Taurus cores evolve to star formation without dissipating turbulence. The critical equilibrium state in the virial analysis corresponds to the critical Bonnor-Ebert sphere in the Bonnor-Ebert analysis (Nakano 1998). It is suggested that the initial condition of the molecular cloud cores/globules for star formation is close to the critical equilibrium state/critical Bonnor-Ebert sphere, in the low-mass star forming region.

Swelling Behavior and Drug Release of Poly(vinyl alcohol) Hydrogel Cross-Linked with Poly(acrylic acid)

  • Byun, Hong-Sik;Hong, Byung-Pyo;Nam, Sang-Yong;Jung, Sun-Young;Rhim, Ji-Won;Lee, Sang-Bong;Moon, Go-Young
    • Macromolecular Research
    • /
    • v.16 no.3
    • /
    • pp.189-193
    • /
    • 2008
  • Thermal cross-linking method of poly(vinyl alcohol) (PVA) using poly(acrylic acid) (PAA) was carried out on PVA/PAA hydrogels. The level of gelation was measured in the PVA/PAA hydrogels with various PAA contents. The swelling behavior at various pHs showed that the swelling kinetics and water contents of the PVA/PAA hydrogels reached equilibrium after 30 h, and the time to reach the equilibrium state decreased with increasing PAA content in the hydrogel. The water content increased with increasing pH of the buffer solution. The permeation and release of the drug were tested using indomethacin as a model drug. The permeated and released amounts of the drug increased with decreasing the PAA content because of the low free volume in the hydrogel due to the higher cross-linking density. The kinetic profile of drug release at various pHs showed that all samples reached the equilibrium state within the 5 h.

Slope Stability Assessment for Colluvial Soil Slumps of the Danyang Region (단양지역 붕적토 붕괴사면의 안정평가)

  • Bae, Woo-Seok;Lee, Bong-Jik;Jang, Kwang-Tak
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.74-80
    • /
    • 2007
  • In this study, a documentary survey, face mapping, and stability analysis were performed on the collapsed colluvial soil slope. The purpose of this paper is to identify the cause of slope failure and determine slope stability for similar areas. Boring samples were extracted from the slump and laboratory tests were performed to find out the cause of slope failure. In addition, the limit equilibrium method was used in order to determine the stability of the slope. As a result of this investigation and the analysis of data, the type of collapse and cause of slope failure have been shown to have a strong correlation with the natural geographical and geological features which make up the collapse profile of the study area. These results will help to develop guidelines for formulating countermeasure methods.

Application of Energy-Efficient Distillation System in Ethanol Process (에너지 절약형 증류시스템의 에탄올 제조공정에의 응용)

  • Lee, Moon Yong;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.892-897
    • /
    • 2008
  • A new ethanol dehydration process utilizing a thermally coupled distillation column is proposed to reduce the energy requirement of the existing dehydration processes. An entrainer of benzene is used in the proposed system having the column profile similar to the equilibrium composition profile for the maximum distillation column efficiency, and the feed composition is arranged to close to the boundary of different distillation regions. It is found that the proposed distillation system gives some 18% of energy saving over the existing process. In addition, design guidelines are suggested for other azeotropic distillation process.

ON COMPLEX VARIABLE METHOD IN FINITE ELASTICITY

  • Akinola, Ade
    • Journal of applied mathematics & informatics
    • /
    • v.12 no.1_2
    • /
    • pp.183-198
    • /
    • 2003
  • We highlight the alternative presentation of the Cauchy-Riemann conditions for the analyticity of a complex variable function and consider plane equilibrium problem for an elastic transversely isotropic layer, in finite deformation. We state the fundamental problems and consider traction boundary value problem, as an example of fundamental problem-one. A simple solution of“Lame's problem”for an infinite layer is obtained. The profile of the deformed contour is given; and this depends on the order of the term used in the power series specification for the complex potential and on the material constants of the medium.

Analysis on the Langmuir adsorption isotherm at the $Pt/H_2SO_4$ electrolyte interface using the ac impedance measurement and phase-shift method ($Pt/H_2SO_4$ 전해질 계면에서 교류임피던스 측정과 위상이동 방법에 의한 Langmuir 흡착등온식 해석)

  • Chun Jang Ho;Cho Sung Chil;Son Kwang Chul
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.1
    • /
    • pp.23-26
    • /
    • 1999
  • The Langmuir adsorption isotherm at the $(Pt)/0.1M\;H_2SO_4$ electrolyte interface has been qualitatively analyzed using the ac impedance measurement and phase-shift method. The phase shift $(\phi)$ depends on both the cathode potential (E<0) and frequency (f) and is inversely proportional to the factional surface coverage $(\theta)$. At an intermediate frequency band (ca. $1\~100$ Hz), the phase-shift profile $(\phi\;vs.\;E)$ can be related to the fractional surface coverage $(\theta\;vs.\;E)$. The phase-shift profile $(\phi\;vs.\;E)$ can be used as an experimental method to estimate and analyze the Langmuir adsorption isotherm $(\theta\;vs.\;E)$. The equilibrium constant (K) and the standard free energy $({\Delta}G_{ads})$ of the adsorbed hydrogen atom $(H_{ads})\;and\;3\times10^{-4}$ and 20.1 kJ/mol, respectively.

Mechanical behaviour of composite columns composed of RAC-filled square steel tube and profile steel under eccentric compression loads

  • Ma, Hui;Xi, Jiacheng;Zhao, Yaoli;Dong, Jikun
    • Steel and Composite Structures
    • /
    • v.38 no.1
    • /
    • pp.103-120
    • /
    • 2021
  • This research examines the eccentric compression performance of composite columns composed of recycled aggregate concrete (RAC)-filled square steel tube and profile steel. A total of 17 specimens on the composite columns with different recycled coarse aggregate (RCA) replacement percentage, RAC strength, width to thickness ratio of square steel tube, profile steel ratio, eccentricity and slenderness ratio were subjected to eccentric compression tests. The failure process and characteristic of specimens under eccentric compression loading were observed in detail. The load-lateral deflection curves, load-train curves and strain distribution on the cross section of the composite columns were also obtained and described on the basis of test data. Results corroborate that the failure characteristics and modes of the specimens with different design parameters were basically similar under eccentric compression loads. The compression side of square steel tube yields first, followed by the compression side of profile steel. Finally, the RAC in the columns was crushed and the apparent local bulging of square steel tube was also observed, which meant that the composite column was damaged and failed. The composite columns under eccentric compression loading suffered from typical bending failure. Moreover, the eccentric bearing capacity and deformation of the specimens decreased as the RCA replacement percentage and width to thickness ratio of square steel tube increased, respectively. Slenderness ratio and eccentricity had a significantly adverse effect on the eccentric compression performance of composite columns. But overall, the composite columns generally had high-bearing capacity and good deformation. Meanwhile, the mechanism of the composite columns under eccentric compression loads was also analysed in detail, and the calculation formulas on the eccentric compression capacity of composite columns were proposed via the limit equilibrium analysis method. The calculation results of the eccentric compression capacity of columns are consistent with the test results, which verify the validity of the formulas, and the conclusions can serve as references for the engineering application of this kind of composite columns.

Gastrointestinal Absorption of Phenytoin from on Oil-in-water Microemulsion

  • Kwon, Kwang-Il;Bourne, David-W.A.
    • Archives of Pharmacal Research
    • /
    • v.20 no.5
    • /
    • pp.480-485
    • /
    • 1997
  • The absorption profile of phenytoin Na emulsion were examined compared to that of phenytoin suspension after oral administration in the rat. The corn oil-in-water emulsion, particle size of $184{\pm}$57.8 nm, was prepared using a microfludizer, and phenytoin Na added by shaft homogenizer. The phenytoin emulsion or suspension, 100 mg/kg, were intubated intragastrically using oral dosing needle and blood samples were withdrawn via an indwelling cannula from the conscious rat. Plasma concentrations of phenytoin were measured with HPLC using phenacetin as an internal standard. The plasma concentration versus time data were fitted to a one compartment open model and the pharmacokinetic parameters were calculated using the computer program, Boomer. The phenytoin plasma concentrations from the emulsion at each observed time were about 1.5-2 times higher than those from the suspension, significantly at time of 5, 6 and 7 hr after administration. The absorption $(k_a)$ and elimination rate constant $(k_e)$ were not altered significantly, however the AUC increased from 65.6 to $106.7{\mu}ghr/ml$ after phenytoin suspension or emulsion oral administration, respectively. From an equilibrium dialysis study, the diffusion rate constant $(k_{IE})$ was considerably higher from the phenytoin Na emulsion $(0.0439 hr{-1})$ than phenytoin suspension $(0.0014 hr{-1})$.

  • PDF

A Study on Oxy-Fuel Combustion System with Multi-Jet Burner-Numerical Simulation with PDF Combustion Model (다공 동축 버너를 이용한 순산소 연소 시스템에 관한 연구-PDF 연소 모델을 이용한 수치해석)

  • Kim, Hyeon-Jun;Choi, Won-Young;Bae, Soo-Ho;Hong, Jung-Goo;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.7
    • /
    • pp.504-512
    • /
    • 2008
  • The characteristics of nonpremixed oxy-fuel flame in a multi-jet burner were experimentally and numerically investigated. The overall flow rate of fuel and oxygen was fixed, and the oxygen feeding ratio (OFR) was varied by 0.25, 0.5, and 0.75. The results of numerical simulation were compared with the measured results which are temperature profile and direct flame observation. The probability density function (PDF) model was applied accounting to the description between turbulence and chemistry, and standard ${\kappa}-{\varepsilon}$ model was used for turbulent flow field. Equilibrium assumption is very reasonable due to fast chemistry of the oxy-fuel combustion. Thus, the equilibrium calculation based on Gibbs free energy minimization was guaranteed to generate the solution of the oxy-fuel combustion. The result was obtained by numerical simulation. The predicted radial temperature profiles were in good agreement with the measured results. The flame length was shorten and was intensified with the decrease of OFR because the mixture of fuel and oxidizer are fast mixed and burnt. The maximum temperature became lower as the OFR increased, as a consequence of large flame surface area.

Numerical Approach for Frequency-Shifting Analysis of Electrostatic Micro-Mechanial Actuator (정전기력을 이용한 미소기전 구동기의 고유치 변화 해석에 관한 연구)

  • Lee, Wan-Sul;Kwon, Kie-Chan;Kim, Bong-Kyu;Cho, Ji-Hyon;Youn, Sung-Kie
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.854-859
    • /
    • 2001
  • An eigenvalue analysis of a tunable micro-mechanical actuator is presented. The actuator is modeled as a continuum structure. The eigenvalue modified by the tuning voltage is computed through the linearization of the relation between the electrostatic force and the displacement at the equilibrium. A staggered algorithm is employed to perform the coupled analysis of the electrostatic and elastic fields. The stiffness matrix of the actuator is modified at this equilibrium state. The displacement field is perturbed using an eigenmode profile of the actuator. The configuration change of the actuator due to perturbation modifies the electrostatic field and thus the electrostatic force. The equivalent stiffness matrix corresponding to the perturbation and the change in the electrostatic force is then added to stiffness matrix in order to explain natural frequency shifting. The numerical examples are presented and compared with the experiments in the literatures.

  • PDF