• 제목/요약/키워드: Equilibrium Air

검색결과 301건 처리시간 0.03초

비접촉식 웨이퍼 그리퍼용 공압 파지식 헤드 설계 (Design of the Air Pressure Pick-up Head for Non-Contact Wafer Gripper)

  • 김준현
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.401-407
    • /
    • 2012
  • The recent manufacturing process in the thin wafers and flat panel necessitate new approaches to reduce handling fragile and surface-sensitive damage of components. This paper presents a new pneumatic levitation for non-contact handling of parts and substrates. This levitation can achieve non-contact handling by blowing air into an air pressure pick-up head with radial passages to generate a negative pressure region. Negative pressure is caused by the radial air flow by nozzle throat and through holes connecting to the bottom region. The numerical analysis deals with the levitational motion with different design factors. The dynamic motion is examined in terms of force balance(dynamic equilibrium) occurring to the flow field between two objects. The stable equilibrium position and the safe separation distance are determined by analyzing the local pressure distribution in the fluid motion. They make considerable design factors consisting the air pressure pick-up head. As a result, in case that the safe separation distance is beyond 0.7mm, the proposed pick-up head can levitate stably at the equilibrium position. Furthermore, it can provide little effect of torque, and obtain more wide picking region according to the head size.

X선치료 조사야 내 공동의 존재에 따른 선량분포의 측정 (The Influence of Air Cavity on Interface Doses for Photon Beams)

  • 정세영;김영범;권영호;김유현
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.69-77
    • /
    • 1998
  • When a high energy photon beam is used to treat lesions located in the upper respiratory air passages or in maxillary sinus, the beams often must traverse an air cavity before it reaches the lesion. Because of this traversal of air, it is not clear that the surface layers of the lesion forming the air-tumor tissue interface will be in a state of near electronic equilibrium; if they are not, underdosing of these layers could result. Although dose corrections at large distances beyond an air cavity are accountable by attenuation differences, perturbations at air-tissue interfaces are complex to measure or calculate. This problem has been investigated for 4MV and 10MV X-ray beams which are becoming widely available for radiotherapy with linear accelerator. Markus chamber was used for measurement with variouse air cavity geometries in X-ray beams. Underdosing effects occur at both the distal and proximal air cavity interface. The magnitude depended on geometry, energy, field sizes and distance from the air-tissue interfaces. As the cavity thickness increased, the central axis dose at the distal interface decreased. Increasing field size remedied the underdosing, as did the introduction of lateral walls. Fellowing a $20{\times}2{\times}2\;cm^3$\;air\;cavity,\;4{\times}4\;cm\;field\;there\;was\;an\;11.5\%\;and\;13\%\;underdose\;at\;the\;distal\;interface,\;while\;a\;20{\times}20{\times}2\;cm^3\;air\;cavity\;yielded\;a\;24\%\;and\;29\%$ loss for the 4MV and 10MV beams, respectively. The losses were slightly larger for the 10MV beams. The measurements reported here can be used to guide the development of new calculation models under non-equilibrium conditions. This situation is of clinical concern when lesions such as larynx and maxillary carcinoma beyond air cavities are irradiated.

  • PDF

조사면내 공동의 존재에 따른 선량분포의 변화측정 (The Measurement of Dose Distribution in the Presence of Air Cavity and Underdosing Effect Result from Lack of Electronic Equilibrium)

  • 조정희;방동완;박재일
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.75-81
    • /
    • 1996
  • When high energy photon beam is incident upon an air cavity interface the effect of ionization build-up observed . This phenomenon is resulting from the surface layers of the lesions are significant deficiency of electrons reaching the layers because of the replacement, of solid scattering material by the air cavity, that is lack of electronic equilibrium. Measurement have been made in an acrylic phantom with a parallel plate chamber and high energy photon beams, CO-60, 4MV, 6MV and 10MV X-rays have been investigated. The result of our study show that a significant effect was measured and was determined to be very dependent on field size, air cavity dimension and photon energy. The reductions were much larger for 10MV beam, underdosage at the interface was 12, 12.2, 16.9 and $20.6\%$ for the CO-60, 4MV, 6MV and 10MV, respectively. It was found that this non-equilibrium effect at the interface is more severe for the higher energy beams than that of lower energy beams and the larger cavity dimensions the larger beam reductions occur. This problem is of clinical concern when lesions such as carcinoma beyond air cavities are irradiated, such as larynx, glottic and the patients with maxillectomy and ethmoidectomy and so forth.

  • PDF

조사면 내 공동의 존재에 따른 선량분포의 변화측정 (The Measurement of Dose Distribution in the Presence of Air Cavity and Underdosing Effect Result from Lack of Electronic Equilibrium)

  • 조정희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.81-87
    • /
    • 1996
  • When high energy photon beam is incident upon an air cavity interface the effect of ionization build-up observed. This phenomenon is resulting from the surface layers of the lesions are significant deficiency of electrons reaching the layers because of the replacement of solid scattering material by the air cavity, that is lack of electronic equilibrium. Measurement have been made in an acrylic phantom with a parallel plate chamber and high energy Photon beams, CO-60, 4MV, 6MV and 10MV X-rays have been investigated. The result of our study show that a significant effect was measured and was determined to be very dependent on field size, air cavity dimension and photon energy. The reductions were much larger for 10MV beam, underdosage at the interface was 12, 12.2, 16.9 and 20.6% for the CO-60, 4 MV, 6MV and 10MV, respectively. It was found that this non-equilibrium effect at the interface is more severe for the higher energy beams than that of lower energy beams and the larger cavity dimensions it is, the larger beam reductions we have. This problem is of clinical concern when lesions such as carcinoma beyond air cavities are irradiated, such as larynx, glottic and the patients with maxillectomy and ethmoidectomy and so forth.

  • PDF

$CH_4-O_2$ Vitiated 공기가열기에서의 오염도 분석 (Analysis of Contaminants in a $CH_4-O_2$ Vitiated Air Heater)

  • 나재정;이정민;임진식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.447-450
    • /
    • 2010
  • $CH_4-O_2$ vitiated 공기가열기에서의 유동 오염도 분석을 위해 가열기 및 노즐 영역에 대한 평형 및 평형 유동장 계산을 수행하였다. 유동장은 일차원 비점성 유동으로 가정하였으며 계산 결과는 측정값과 비교하였다. 연구결과 연소 지연이나 중단 현상에 영향을 주는 오염원으로써 NO 성분의 존재를 파악하기 위해서는 비평형 유동장 계산이 고려되어야 함을 알 수 있었다.

  • PDF

승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화 (Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles)

  • 지준호;강석훈;황정호;배귀남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

R-410A/POE 오일 혼합물의 기-액상평형과 상용성에 관한 연구 (Investigation of Vapor-Liquid Equilibrium and Miscibility for R-410A/POE Oil Mixtures)

  • 김창년;송준석;이은호;박영무;유재석;김기현
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.589-598
    • /
    • 2000
  • The vapor-liquid equilibrium and miscibility measurement apparatus was developed and used to obtain data for refrigerant/oil mixture. The vapor-liquid equilibrium and miscibility data for R-410a/POE32 and R-410A/POE46 oil mixtures are obtained over the temperature range from -20 to $60^{\circ}C\;with\;10^{\circ}C$ intervals and the oil concentration range from 0 to 90 wt%. Using the experimental data, an empirical model is developed to predict the temperature-pressure-concentration relations for R-410A/POE oil mixtures at equilibrium. In the R-410A/POE32 oil mixture, the average root-mean-square deviation between measured data and calculated results from the empirical model is 2.00% and in the R-410a/POE46 oil mixture, that is 3.69%. Flory-Huggins theory is also used to predict refrigerant/oil mixture behavior. Miscibility for R-410A/POE32 oil mixture was observed all over the experimental conditions. Immiscibility for R-410A/POE46 oil mixture was observed at the low oil concentrations(10~30 wt%).

  • PDF

ANALYTIC APPROACH FOR THE STUDY OF AIR AND/OR LIQUID FILLED GEOMEMBRANE TUBE SECTIONS ON A HORIZONTAL

  • Choi, Yoon-Rak
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제17권3호
    • /
    • pp.181-195
    • /
    • 2013
  • This study considers an air and liquid-filled geomembrane tube section resting on a horizontal foundation. All quantities are normalized to obtain geometrically similar solutions in the static equilibrium condition. Analytic solutions are expressed in closed form. The solution for the air or liquid-filled tube section is derived systematically as an extreme case of the air and liquid-filled tube section. The validity of these solutions is confirmed by comparing to previous study, and some results are shown for the characteristic parameters and shapes of air and/or liquid-filled cases. Using the result of present study, one can estimate the shape and characteristic parameters of a tube section without numerical integrations or iterations.

대구지방의 기상자료를 기초로한 벼의 상온통풍건조에 관한 조사연구 (Investigation of Natural Air Drying of Rough Rice Based on The Weather Data in Taegu Area)

  • 김재열;서승덕;금동혁;서석건
    • Journal of Biosystems Engineering
    • /
    • 제5권1호
    • /
    • pp.15-23
    • /
    • 1980
  • Natural-air drying systems have been extensively used for cereal grains, and many researches on the systems have been conducted in foreign countries. However, little research on drying rough rice with natural air has been done. Especially . little research on natural air drying of rough rice based on weather data has been done in Korean. The objective of this study was to present fundamental data for estimating optimum requirements and basic information available for natural air drying of rough rice based on the weather data . The weather data analyzed in this study were the 10-year (1969 to 1978) record of air temperatures, wet-bulb temperatures and relative humidities, which were three-hourly observations in Taegu area. The results of this study are summarized as follows ; 1 From the results of weather data analysis the average air temperature was about $14.8^\circ$and the average relative humidty 67.5% . Average equilibrium moisture content appeared to be 13.8 percent on wet basis, which showed great potential for natural air drying in Taegue area in October. 2. Possible fan operation time based on the equilibrium moisture content of 15% on wet basis was about 14 hours a day during October in Taegu area. Probabilities of possible drying days based on minimum time available for drying in a day were analyzed. 3. Minimum air flow requirements based on the worst year were determined for different fan operation methods and initial moisture contents.

  • PDF

식물을 이용한 대기 중 PCBs의 농도 예측 평가 (Estimation of Bio-Monitoring for PCBs Concentration in Air Using Plant)

  • 여현구;최민규;천만영;김태욱;선우영
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.265-274
    • /
    • 2002
  • The concentrations of polychlorinated biphenyls (PCBs) in air and plant were measured every other week at Hankyong University located in Ansung, Kyoung-ki province from July to November of 1999. The predicted PCB concentrations in air derived from measured Morus allba were compared with ambient measurement data. This was necessary to test the possibility of using the two equations incorporating Riederer's and Bacci's bioconcentration factors (BCFs) based on the octanol-air partition coefficient (Ksub/oa/) to predict the air-plant equilibrium of PCBs. Ratios of calculated to measured PCB concentrations in air were 2.4 (1.24~4.36), 2.7 (0.17~7.96) using Riederer's and Bacci's equations, respectively Regression analysis between PCBs calculated by Riederer's equation and PCBs directly measured in air, showed correlation ($R^2$= 0.90). However, slope of regression between calculated and directly measured PCB concentrations was above 1. The results thus suggest that calculated PCBs were overestimated comparing with direct measurements. Bio-monitoring using Morus allba may have possibilities in predicting PCBs concentration in air with a further extension of air-plant equilibrium research.