• 제목/요약/키워드: Equal value line

검색결과 37건 처리시간 0.028초

이론 및 실험에 의한 제체의 침윤선에 관한 연구 (A Study on Seepage line of Dam body by Finite Element method and Experiment.)

  • 신문섭;안상진
    • 물과 미래
    • /
    • 제14권2호
    • /
    • pp.53-62
    • /
    • 1981
  • 댐이나 제방과 같이 흙으로 축조된 수리구조물에 있어서, 자유지하수면의 최상부 침투선을 해석하였다. 자유지하수면에 작용하는 압력은 대기압이고, 침투선은 유선이라는 원리에 의하여 연구를 수행하였다. 미지의 침투선을 해석하기 위하여 Galerkin 원리에 기초를 둔 유한요소법에 의하여 다공체속을 흐르는 정류상태의 침투수를 해석하여 실험치와 이론치를 비교하였고 그 결과 이론치와 실험치가 거의 일치함을 알았다. 결론적으로 침투선해석에 있어서 유한요소법이 실험적인 방법보다 더 실용적이라는 것을 알았다.

  • PDF

저수지 운영을 위한 한국 하천 유출 모형의 비교 (Comparison of streamflow runoff model in Korea for applying to reservoir operation)

  • 노재경;이재남
    • 농업과학연구
    • /
    • 제38권3호
    • /
    • pp.513-524
    • /
    • 2011
  • To evaluate the applicability of inflow runoff model to reservoir operation in Korea, DAWAST model and TPHM model which are conceptual lumped daily runoff model and were developed in Korea, were selected and applied to simulate inflows to Daecheong multipurpose dam with watershed area of 4,134 $km^2$, and water storages in Geryong reservoir with watershed area of 15.1 $km^2$ and total water storage of 3.4 M $m^3$. Evaluating inflows on an yearly, monthly, ten-day, and daily basis, inflows by DAWAST model showed balanced scatters around equal value line. But inflow by TPHM model showed high in high flows. Annual mean water balance by DAWAST model was rainfall of 1,159.9 mm, evapotranspiration of 622.1 mm, and inflow of 644.6 mm, from which rainfall was 104.8 mm less than sum of evapotranspiration and inflow, and showed unbalanced result. Water balance by TPHM model showed satisfactory result. Reservoir water storages were shown to simulate on a considerable level from applying DAWAST and TPHM models to simulate inflows to Geryong reservoir. But it was concluded to be needed to improve DAWAST and TPHM model together from imbalance of water balance and low estimation in high flow.

Cephalometrically assessing the validity of superior, middle and inferior tragus points on ala-tragus line while establishing the occlusal plane in edentulous patient

  • Chaturvedi, Saurabh;Thombare, Ram
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.58-66
    • /
    • 2013
  • PURPOSE. The purpose of this study was to decide the most appropriate point on tragus to be used as a reference point at time of marking ala tragus line while establishing occlusal plane. MATERIALS AND METHODS. The data was collected in two groups of subjects: 1) Dentulous 2) Edentulous group having sample size of 30 for each group with equal gender distribution (15 males, 15 females each). Downs analysis was used for base value. Lateral cephalographs were taken for all selected subjects. Three points were marked on tragus as Superior (S), Middle (M), and Inferior (I) and were joined with ala (A) of the nose to form ala-tragus lines. The angle formed by each line (SA plane, MA plane, IA plane) with Frankfort Horizontal (FH) plane was measured by using custom made device and modified protractor in all dentulous and edentulous subjects. Also, in dentulous subjects angle between Frankfort Horizontal plane and natural occlusal plane was measured. The measurements obtained were subjected to the following statistical tests; descriptive analysis, Student's unpaired t-test and Pearson's correlation coefficient. RESULTS. The results demonstrated, the mean angle COO (cant of occlusal plane) as $9.76^{\circ}$, inferior point on tragus had given the mean angular value of IFH [Angle between IA plane (plane formed by joining inferior point-I on tragus and ala of nose- A) and FH plane) as $10.40^{\circ}$ and $10.56^{\circ}$ in dentulous and edentulous subjects respectively which was the closest value to the angle COO and was comparable with the values of angle COO value in Downs analysis. Angulations of ala-tragus line marked from inferior point with occlusal plane in dentulous subject had given the smallest value $2.46^{\circ}$ which showed that this ala-tragus line was nearly parallel to occlusal plane. CONCLUSION. The inferior point marked on tragus is the most appropriate point for marking ala-tragus line.

단일 시험편법에 의한 극저온용 구조재료의 파괴인성 저하에 관한 연구 (A study on the fracture toughness degradation in cryogenic structural material using single-specimen method)

  • 권일현
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.343-351
    • /
    • 1998
  • This paper was investigated degradation of the fracture toughness caused by sensitizing heat-treatment of the cryogenic structural material JN1 base metal using unloading compliance method reported as useful a method in evaluating the elastic-plastic fracture toughness at cryogenic temperature. The specimens used in this paper were 20% side-grooved 0.5T-CT specimens which were machined in the JN1 base metal. Also, to investigate cryogenic fracture toughness of the fusion line region in the JN1 GTA weldments, it was also used 20% side-grooved 0.5T-CT specimens that was machined fusion line to located in the middle of the specimen. The cryogenic fracture toughness values of the JN1 base metal were significantly decreased with increasing the time and temperature of the heat treatment. The fracture toughness value obtained from the fusion line specimen was invalid, but it was lower value than that of the JN1 base metal. Especially, this value was approximately equal with that obtained from the JN1 650.deg. C-5h heat-treated material.

Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard

  • Rastogi, Abhishek;Kamble, Vikas
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.69-75
    • /
    • 2011
  • This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (${\alpha}$=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at $30 \;{mu}m$ revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy.

임피던스 변환회로의 신호 전달특성(S21) 측정 방법 (Measurement method of the signal transfer characteristic(S21) of the impedance transformer)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1282-1289
    • /
    • 2019
  • 임피던스 변환회로의 신호 전달특성(S21)을 측정하기 위해서는 두 개의 임피던스 변환회로를 대칭 연결하여야 한다. 하지만 두 개의 임피던스 변환회로를 대칭 연결한 회로의 신호 전달특성은 중간 연결 선로의 길이에 의해 영향을 받는다. 본 논문에서는 임피던스 변화회로의 정확한 신호 전달특성을 얻기 위한 중간 연결 선로의 길이를 수식으로 유도하였다. 수식을 이용하여 계산하면 4:1(50-Ω:12.5-Ω) 임피던스 변환회로의 정확한 신호 전달특성을 얻기 위한 중간 연결 선로의 전기적 길이는 약 45°이다. 계산된 연결 선로의 길이를 적용하여 1GHz에서 λ/4-마이크로스트립 임피던스 변환회로를 제작하여 신호 전달특성을 측정하였다. 제작된 대칭 연결된 임피던스 변환회로의 신호 반사 특성(S11)은 0.980GHz에서 -40.64dB, 신호 전달 특성(S21)은 -0.154dB였다. 이는 제작 회로에 대해 이론적으로 살펴본 중심 주파수의 987MHz 변화, 마이크로스트립 선로의 신호 손실 -0.15dB 값과 거의 동일한 값이다.

A forensic study of the Lubbock-Reese downdraft of 2002

  • Holmes, J.D.;Hangan, H.M.;Schroeder, J.L.;Letchford, C.W.;Orwig, K.D.
    • Wind and Structures
    • /
    • 제11권2호
    • /
    • pp.137-152
    • /
    • 2008
  • This paper discusses engineering aspects of the rear-flank downdraft that was recorded near Lubbock, Texas on 4 June 2002, and produced a gust wind speed nearly equal to the design value (50-year return period) for the region. The general characteristics of the storm, and the decomposition of the time histories into deterministic 'running mean' and random turbulence components are discussed. The fluctuating wind speeds generated by the event can be represented as a dominant low-frequency 'running mean' with superimposed random turbulence of higher frequencies. Spectral and correlation characteristics of the residual turbulence are found to be similar to those of high-frequency turbulence in boundary-layer winds. However, the low-frequency components in the running-mean wind speeds are spatially homogeneous, in contrast to the low-frequency turbulence found in synoptic boundary-layer winds. With respect to transmission line design, this results in significantly higher 'span reduction factors'.

이동체 통신용 안테나에 관한 연구 (A Study on the Antenna for Mobile Communication)

  • 고영혁;김재민;이종악
    • 한국전자파학회논문지
    • /
    • 제7권2호
    • /
    • pp.139-146
    • /
    • 1996
  • 본 논문에서 MSA(Microstrip Antenna)의 변형인 QMSA(Quarter-wavelength Microstrip Antenna)에 용량을 장하한 미소 루프 구조와 용량을 장하시킨 부분에서 방사하는 개구 구조에 의한 합성 전계 안테나를 제안 하였다. 그리고 합성 전제 특성은 계산된 값과 실험 값이 양호하게 일치함을 보였다. 제안된 안테나는 그라운드판과 방사 소자의 폭이 같은 소형화된 안테나이다. 설계.제작된 안테나는 동작 주파수 1.5GHz에서 수직.수평 편파를 각각 수신할 수 있다. 그리므로 이 안테나는 무선 전화를 위한 소형화된 안테나로써 이용할 수 있고, 실내 통신을 위해 아주 유용하다. 또한, 전송 선로 모델의 안테나 등가 회로는 정확한 공진 주파수를 찾기 위해 설계되었고, 리턴로스 값을 계산했다. 계산된 값은 실험값과 양호하게 일치되었다.

  • PDF

흙의 다짐에 관한 연구 (제2 보) -200번체 통과율이 다짐에 미치는 영향- (Study on the Soil Compaction (part II) The Influence of Passing Percentage of No. 200 Sieve on Soil Compaction)

  • 강문묵
    • 한국농공학회지
    • /
    • 제12권1호
    • /
    • pp.1854-1860
    • /
    • 1970
  • Results of this study on the influence of percent passing of No. 200 sieve on soil compaction are as follows; 1. The higher maximum dry density of soil is, the lower optimum moisture content is. Maximum dry density is highest value and optimum moisture content is the lowest value in twocases that percents of No. 200 sieve are 30% in soils of which percents retained on No. 10 sieve are 5% and 10% respectively. 2. Maximum dry density increases according as uniformity coefficient increase. Maximum dry density is the highest when uniformity coefficient is approximately 300 in soil of which maximum diameter is 4.76mm. 3. Maximum dry density has a tendency to become large according as value of Cu Caincrease. Correlation between maximum dry density and $Log_{10}$(CuCa) shows straight line. 4. Maximum dry density increases according as n increase and reaches the peak when n equal 0.35 in condition that the index of talbot formula n is less than 0.35 in soil of which maximum diameter is 4.76mm. 5. Maximum dry density has a tendency to increase according as value of Cg $(Cg=\frac{P_{50}^2}{P_{10}{\times}{P_{200}}$) decrease.

  • PDF

잔류응력이 응력세기계수와 피로균열성장율에 미치는 영향 (The Effect of Residual Stress on Stress Intensity Factor and Fatigue Crack Growth Rate)

  • 이강용;김홍기
    • 대한조선학회지
    • /
    • 제21권1호
    • /
    • pp.43-47
    • /
    • 1984
  • The purpose of this paper is to investigate theoretically the effect of residual stress due to welding in stress intensity factor of a plate containing the Model I Crack in different crack size and location, and on fatigue crack growth rate. The initiation of crack is found to be possible only in the region of tensile residual stress. The most dangerous crack has the values of d/b and a/b equal to about 0.6 and 1.0, respectively, where d/b is the ratio of distance from the crack to welding bead and the width of tensile residual stress region and a/b is the ratio of crack length and tensile residual stress region. The crack perpendicular to and on the line of welding bead and with a/b equal to about 0.6 has maximum stress intensity factor. The theoretical fatigue crack growth rate under residual stress and applied stress, which is obtained from Forman's Law by stress superposition, is relatively in good agreement with Glinka's[8] experimental value. The fatigue crack growth is shown to be retarded due to residual stress distribution.

  • PDF