• 제목/요약/키워드: Equal Load

검색결과 348건 처리시간 0.022초

치과용 골유착성 임플랜트 고정체 형상의 응력 분산에 관한 연구 (STUDIES OF OSSEOINTEGRATED IMPLANT-MODELS ON STRESS DISTRIBUTION)

  • 한종현;전흥재;정신영;허성주;최용창;정종평;구영;류인철;김명호
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.526-543
    • /
    • 2000
  • Finite element analyses were performed to study effects on stress distribution generated in jaw bone for various shapes of dental implants: plateau type, plateau with small radius of curvature, triangular thread screw type in accordance with ISO regulations and square thread screw filleted with small radius partially. It was found that square thread screw filleted with small radius was more effective on stress distribution than other dental implants used in analyses. Additional analyses were performed on the implant with square thread screw filleted with small radius for very-ing design parameters, such as the width of thread end, the height of the thread of the implant and load direction, to determine the optimum dimensions of the implant. The highest stress concentration occurred at the region in jaw Pone adjacent to the first thread of the implant. The maximum effective stress induced by a 15 degree oblique load of 100 N was twice as high as the maximum effective stress caused by an equal amount of vertical load. Stress distribution was more effective in the case when the width of thread end and the height of thread were p/2 and 0.46p, respectively, where p is the pitch of thread. At last, using tensile force calculated from the possible insert torque without breading bone thread, finite element analysis was performed on the implant to calculate pre-stress when the primary fixation of the implant was operated in jaw bone. The maximum effective stress was 136.8 MPa which was proven to be safe.

  • PDF

항공우주 비행체 정적구조시험용 하중제한밸브 부품 형상 분석 (Geometrical Analysis on Parts of Load Limit Valve for Static Structural Test of Aerospace Flight Vehicles)

  • 심재열
    • 한국항공우주학회지
    • /
    • 제47권9호
    • /
    • pp.607-616
    • /
    • 2019
  • 항공우주비행체 정적구조시험을 위한 과하중 방지를 위해 사용되는 하중제한밸브(LLV)의 파일럿 스테이지의 주요 구성품들에 대한 자유물체도 분석을 수행하였다. 이 분석을 통하여 유압작동기의 동일한 힘에서 일관성있게 포펫 개방되도록 하기 위해서는 파일럿스테이지에 있는 두 포펫의 직경비($(D_2)^{ten}/D_2)^{comp}$)가 작동기의 피스톤 면적비($A_{comp}/A_{ten}$)와 동일해야만 한다는 것을 보였다. 실험실에서 외산으로 수입하여 사용하고 있는 4개의 서로 다른 하중제한밸브의 포펫들 형상을 측정하고 대응되는 4개의 다른 용량을 갖는 유압작동기들의 피스톤 면적비들로부터 위의 분석결과가 타당함을 확인하였다. 두 개의 다른 파일럿스테이지로 수행한 "조절자 분해능시험들"의 결과들로부터 조절자 각 회전에서 얻은 Fi(포펫개방 순간의 작동기 힘)의 최대 표준편차는 각 평균값으로부터 0.3KN이고 표준편차를 각 평균값으로 나눈 무차원값으로 분석하면 최대편차는 3.7%이다. 이 결과로 부터 동일 포펫 직경비를 갖는 두 개의 파일럿스테이지들의 포펫은 각 조절자 회전에 대해 Fi/(평균 Fi) 값이 +/- 3.7% 범위에서 일관성 있게 개방되고 있음을 확인하였다. 위의 편차는 포펫 O-링의 마찰력으로부터 유발되는 것임을 보였다. 부가적으로 파일럿스테이지의 다른 주요부품인 포펫 스프링과 조절자의 주요설계인자들도 식별하였고 이들의 결정과정도 본 연구에서 보였다.

LRFD 설계를 위한 국내 항타강관말뚝의 저항계수 산정 (Resistance Factors of Driven Steel Pipe Piles for LRFD Design in Korea)

  • 박재현;허정원;김명모;곽기석
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.367-377
    • /
    • 2008
  • 국내 기초구조물에 대한 하중저항계수설계법 개발의 일환으로 신뢰성에 기반한 항타강관말뚝의 저항계수를 산정하였다. 국내 정재하시험 및 지반조사 자료를 수집, 분석하여 측정 지지력 확인이 가능한 57개 자료에 대해서 선단부 N치 50을 기준으로 두 그룹으로 분류하였다(N<50, $N{\geq}50$). 구조물기초설계기준에서 제안하고 있는 두 가지 정역학적 설계공식에 대해서 대표 측정지지력과 설계지지력을 비교함으로써 저항편향계수를 평가하였다. 저항편향계수의 통계특성을 이용하여 일차신뢰도법 및 몬테카를로 시뮬레이션에 의한 엄밀한 신뢰성 분석을 실시하였다. 신뢰성 분석 결과 및 국내 말뚝기초의 설계, 시공 실무 특성을 종합적으로 고려하여 목표 신뢰도지수를 결정하였다. 무리말뚝의 여용성을 적용할 수 있는 경우 2.0, 2.33, 무리말뚝의 여용성을 적용할 수 없는 경우 2.5의 목표 신뢰도지수를 결정하였고, 일차신뢰도법 및 몬테카를로 시뮬레이션을 적용하여 저항계수를 산정하였다.

수평하중을 받는 테두리보가 있는 플랫플레이트 시스템의 유효보폭계수 (Effective Beam Width for Flat-Plate Systems Having Edge Beams under Lateral Loads)

  • 한상환;조자옥;박영미
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.213-219
    • /
    • 2008
  • 본 연구의 목적은 수평하중 하의 테두리보가 있는 플랫플레이트 시스템의 해석 방법을 제안 하는 것이다. 플랫플레이트 시스템은 보 없이 기둥이 직접 지지하는 구조로 정의되지만 일반적으로 설계에서는 테두리보를 설치하여 사용하고 있다. 수평하중 하의 플랫플레이트를 해석 할 수 있는 방법으로는 ACI 318 (2005)에서 유한요소법, 유효보폭법, 등가골조법을 제시하고 있다. 그 중 유효보폭법은 슬래브를 보요소로 치환함으로써 실용적인 해석이 가능하도록 하는 해석 방법이다. 유효보폭법에서의 보 요소는 슬래브와 같은 두께와 실제 슬래브에 대하여 어떠한 비율로 정의되는 유효보폭으로 정의된다. 그러나 유효보폭법에 관한 연구는 기하학적 변수에 대한 연구나 강성 감소 계수에 관한 연구가 일반적이고 테두리보를 고려해 줄 수 있는 유효보폭모델에 관한 연구는 아직 미미한 실정이다. 본 연구에서는 테두리보가 없는 플랫 플레이트 시스템의 횡 강성보다 테두리보가 있는 플랫플레이트 시스템의 횡 강성이 더 큰 강성을 확보하는 것을 검증하였다. 따라서 테두리보의 영향을 고려할 수 있는 플랫플레이트 시스템의 해석 방법이 제시되어야 할 필요가 있다고 판단된다. 본 연구에서는 수평하중에 대한 테두리보가 있는 플랫플레이트의 유효보폭모델을 제안하였다. 제안된 모델의 검증을 위하여 제안된 유효보폭모델의 결과값을 유한요소해석의 결과값과 비교하였다. 또한 제안된 유효보폭모델의 결과값과 기존에 수행된 실험의 결과와 비교하였다.

산지계류에 있어서 유목의 종단적 분포특성 (Longitudinal Pattern of Large Wood Distribution in Mountain Streams)

  • 서정일;전근우;김민식;염규진;이진호;木村正信
    • 한국산림과학회지
    • /
    • 제100권1호
    • /
    • pp.52-61
    • /
    • 2011
  • 수변역을 구성하는 중요한 요소인 유목은 유역의 생태적 환경에 영향을 미치는 동시에 재해의 요인으로서 인간생활권에 악영향을 미치기도 한다. 그럼에도 불구하고 우리나라에서는 유목의 발생, 이동 및 체류특성에 대한 구체적인 연구가 진행되고 있지 않다. 따라서 이 연구에서는 산지계류에 있어서 유목체류의 종단적 분포의 이질성에 영향을 미치는 인자를 규명하고, 그에 따른 유목체류량의 변화를 해석하기 위해 강원도 인제군에 위치한 기룡산 유역을 대상으로 유목의 종단적 분포특성을 파악하였다. 조사 결과, 조사구간의 평균계폭, 직경 1 m 이상의 거력의 개수 및 이들 간의 상호관계가 유목체류량을 설명하는 최적의 예측자로서 나타났다. 일반적으로 산지계류에 분포하고 있는 거력은 유목의 이동을 방해하는 장해물로서 유목체류에 적절한 물리적 환경을 조성한다. 그러나 이 연구에서는 이러한 거력의 영향이 산지계류의 규모에 따라 다르게 나타나는 것으로 나타났다. 즉 계폭이 좁은 구간의 경우 산지계류 내에 분포하는 거력의 개수가 증가함에 따라 유목체류량 역시 지속적으로 증가한 반면, 계폭이 큰 구간의 경우 유목체류량에 미치는 거력의 개수의 영향이 작은 것으로 나타났다. 이는 계폭이 다른 두 지역에 있어서 동일한 양의 거력들이 존재할 경우 이들에 의한 계폭의 감소비율이 다르기 때문인 것으로 사료된다. 따라서 이러한 유목의 종단적 분포특성 및 이에 영향을 미치는 생태적 물리적 환경을 고려한 계통적이고 체계적인 사방사업이 실시되어야 할 것이다.

탄소성 해석프로그램에 의한 버팀지지 흙막이벽의 변위 비교 (Displacement Comparison of a Braced Retaining Wall by Elasto-Plastic Analysis Program)

  • 신방웅;김상수;오세욱;김동신
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.395-402
    • /
    • 2000
  • Recently, the deep excavations have been peformed to utilize the under ground space. As the ground excavation is deeper, the damage of the adjacent structure and the ground occurs frequently. The analysis of the retaining structures is necessary to the safety of the excavation works. There are many methods such as elasto-plastic, FEM, and FDM to analyze the displacement of the retaining structure. The elasto-plastic method is generally used in practice. In this thesis, GEBA-1 program by the Nakamura-Nakajawa elasto-plastic method was developed. The program for Windows was used the Visual Basic 6.0, and the Main of the program consists of three subroutines, SUB1, SUB2, and SUB3. The lateral displacement of the wall was analyzed by the developed program GEBA-1, SUNEX, and EXCAD, and compared with the measured displacement by the Inclinometer(at three excavation work sites). The excavation method of each site is braced retaining wall using H-pile. Each excavation depth is 14m, 14m, or 8.2m. The results of the analyses are the followings ① In the multi-layer soil, the lateral displacement by the GEBA-1 and EXCAD which is considering the distribution of the strut load is equal to the measured displacement. Elasto-plasto programs can't consider the change of the ground water in clay. Therefore, the analysis displacement was expected only 20% of the measured wall displacement. ③ At the final excavation step, the maximum lateral displacement of analysis and field occurred 7∼18m at the 85∼92% of the excavation depth. ④ The maximum lateral displacement in clay, as 50mm, occurred on the ground surface.

  • PDF

고인성 열가소성 복합재료 AS4/PEEK의 피로강도에 관한 기초적 검토 (A Preliminary Study on Fatigue Strength of High Toughness Thermoplastic Composite Material AS4/PEEK)

  • 송지호;강재윤
    • 대한기계학회논문집A
    • /
    • 제24권4호
    • /
    • pp.1055-1064
    • /
    • 2000
  • First, various specimen geometries, namely, coupon type, waisted type and dog-bone type, were examined to determine appropriate fatigue specimen of thermoplastic composite material AS4/PEEK and the n, fatigue strength of smooth and notched specimens of AS4/PEEK [-45/0/+45/90]2s was investigated. Fatigue tests were performed under load controlled condition at a stress ratio of 0. 1 at a frequency of 5Hz. Stiffness degradation of specimens with fatigue cycling was monitored using an automated unloading compliance technique. The waisted type specimen is found appropriate for smooth fatigue specimen geometry of AS4/PEEK. As for the effect of stress concentration, it is found that fatigue strength is higher for a 2mm-diameter hole notched specimen than a 5mm-diameter one. Fatigue notch factor decreases with the increase of fatigue life. These results are far different from the trend of fatigue strength of metallic materials. The stiffness variation of smooth specimen was only 4% at maximum until final fracture. On the other hand, the stiffness of hole notched specimen was reduced by 45% at maximum. Notched fatigue strength was compared between thermoplastic composite AS4/PEEK and thermosetting composite Graphite/Epoxy. In long-life fatigue (>104), the AS4/PEEK composite shows superior fatigue strength, but in short-life fatigue, the fatigue strength of the Graphite/Epoxy composite is nearly equal or somewhat higher than that of the AS4/PEEK composite.

Mobile Ad Hoc 네트워크에서 이질적 그룹 이동성을 지원하는 논리적 협업 개체 기반의 멀티캐스트 구조 연구 (A Study on Logical Cooperative Entity-Based Multicast Architecture Supporting Heterogeneous Group Mobility in Mobile Ad Hoc Networks)

  • 김갑동;김상하
    • 정보처리학회논문지C
    • /
    • 제14C권2호
    • /
    • pp.171-178
    • /
    • 2007
  • 개별적으로 이동하는 노드들과 그룹으로 이동하는 노드들로 함께 구성된 애드 혹 네트워크에서 멀티케스트 어플리케이션을 수행하는 노드들은 비슷한 이동 특성을 갖는 그룹에 속하는 경우가 많다. 그룹 이동성은 확장성을 향상시키고, 프로토콜 오버헤드를 줄이는 좋은 방법 중 하나이다. 본 논문에서는 이질적 그룹 이동성을 갖는 네트워크에서 동일한 그룹 이동성을 갖는 노드들을 다중 인터페이스의 단일 개체로 간주하여 멀티캐스트 트리를 구성하는 멀티캐스트 구조를 제안한다. 논리적 협업 개제 기반 멀티캐스트 구조의 적용은 비계층적 멀티캐스트 구조를 유지하면서 계층적 멀티캐스트 구조로부터 얻을 수 있는 확장성, 멀티캐스트 트리 단순화, 프로토콜 오버헤드 감소 등을 수용하며, 임의의 노드가 입출력 인터페이스 역할을 함으로서 데이터 포워딩 부하를 여러 노드로 분산시켜 전력 소비의 집중현상을 막을 수 있다. 시뮬레이션을 통하여 다중 인터페이스를 갖는 논리적 협업 개체 기반의 멀티캐스트 프로토콜이 효율적인 데이터 전송과 프로토콜의 확장성을 제공하는 것을 볼 수 있다.

무선 센서 네트워크에서 균등한 클러스터 밀도를 고려한 토큰 기반의 클러스터링 알고리즘 (A Token Based Clustering Algorithm Considering Uniform Density Cluster in Wireless Sensor Networks)

  • 이현석;허정석
    • 정보처리학회논문지C
    • /
    • 제17C권3호
    • /
    • pp.291-298
    • /
    • 2010
  • 무선 센서 네트워크에서 센서노드의 수명은 배터리에 의해 제한되므로 에너지는 가장 중요한 고려사항이다. 클러스터링은 네트워크의 에너지 소비를 효율적으로 관리하는데 사용되는 방법 중 하나이며, LEACH는 대표적인 클러스터링 알고리즘이다. LEACH는 센서 노드들의 에너지 소비를 공평하게 분산시키기 위해 에너지 소모적 기능을 하는 클러스터 헤드를 매 라운드마다 무작위로 순환시키는 방법을 사용하고 있다. 클러스터 헤드의 무작위 선정은 매 라운드 최적의 클러스터 헤드 수를 보장해주지 못한다. 그리고 밀도가 높은 클러스터에 위치한 클러스터 헤드는 과부하 상태가 된다. 본 논문에서는 클러스터 헤드의 수를 보장하기 위한 토큰 기반의 클러스터 헤드 선정 알고리즘과 균등한 밀도의 클러스터 형성을 위한 클러스터 선택 알고리즘을 제안한다. 시뮬레이션을 통하여 제안하는 알고리즘이 LEACH 보다 네트워크 수명이 9.3%정도 연장됨을 보여주었다.

무치악에 대한 최소 임플란트의 구조물의 3차원 유한요소 해석 (The 3-Dimensional Finite Element Analysis of Minimum Implant Structure for Edentulous Jaw)

  • 장인식
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.148-155
    • /
    • 2008
  • The aim of the study is to interpret the distribution of occlusal force by 3-dimensional finite element analysis of ISP(Implant Supported Prosthesis) supported by minimum number of implant to restore the edentulous patients. For this study, the Astra Tech implant system is used. Geometric modeling for 6 and 4 fixture ISP group is performed with respect to the bone, implant and one piece superstructure, respectively. Implants are arbitrarily placed according to the anatomical limit of lower jaw and for the favorable distribution of occlusal force, which is applied at the end of cantilever extension of ISP with 30mm. Element type is tetrahedral for finite element model and the typical mechanical properties, Young's modulus and Poisson's ratio of each material, cortical, cancellous bone and implant material are utilized for the finite element analysis. From this study, we can see the distribution of equivalent stress equal to real situation and speculate the difference in the stress distribution in the whole model and at each implant fixture, From the analysis, the area of maximum stress is distributed on distal contact area between bone and fixture in the crestal bone. The maximum stress is 53MPa at the 0.2mm area from the bone-implant interface in the maximum side for 300N load condition for 4 fixture case, which is slightly less than the stress calculated from allowable strain. This stress has not been deduced to directly cause the loss of crestal bone around implant fixture, but the stress can be much reduced as the old peoples may have lower chewing force. Thus, clinical trial may be performed with this treatment protocol to use 4 fixtured ISP for old patients.