• Title/Summary/Keyword: Environmental sample

Search Result 2,553, Processing Time 0.034 seconds

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF

Health Risk Assessment for Workers Exposed to Diazinon Insecticide (디아지논 취급 근로자의 건강 위험성 평가)

  • Jung, Woo Jin;Kim, Chi Nyon;Won, Jong Uk;Kim, Ki Youn;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.100-106
    • /
    • 2012
  • Objectives: Diazinon is an insecticide which acts as a contact stomach and respiratory poison, and used throughout the world to control a wide range of sucking and chewing insects and mites on a range of crops. In this study, the airborne diazinon levels were measured for farmers, pest control operaters, landscapers, and agricultural chemicals sellers, and an assessment of the health risk to the workers was presented. The exposure scenario was based on the route of inhalation and skin absorption. The "OSHA Method No. 62" was used to sample and measure the airborne diazinon levels. The skin wipe method was applied to measure the level of the diazinone exposure through the skin. For the determination of exposure scenario, the exposure factors were surveyed for the daily average inhalation rate and the exposure period and frequency and time of diazinone as well as the body weight and lifetime of the workers. The median values of exposure frequency and exposure time were selected after evaluating the validity of those. Methods: The highest level of the diazinon exposure in the air was $107.21ug/m^3$ in farmers, followed by $93.53ug/m^3$ in landscapers, at $31.40ug/m^3$ in pest control operators, and $1.04ug/m^3$ in agricultural chemical seller. The amount of skin absorption was the highest in farmers at 63.39 ug/day, followed by landscapers at 10.47 ng/day, pest control operaters at 4.26 ng/day, and agricultural chemicals sellers at 0.34 ng/day. The hazardous indices calculated using toxicological reference value were 2.79 for pest control operaters, 0.41 for landscapers, 0.07 for agricultural chemicals sellers, and 0.06 for farmers. Conclusions: While the farmers were exposed to the high levels of diazinon through the air and skin, the pest control operaters, landscapers and agricultural chemicals sellers have more the diazinon hazards than the farmer based on the risk assessment in this study.

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

  • Lee, Jung-Min;Han, Young-Hwan;Choi, Su-Jeong;Park, Ju-Seong;Jang, Jeong-Jun;Bae, Re-Ji-Na;Lee, Mi Ju;Kim, Myoung Jun;Lee, Yong-Hoon;Kim, Duyeol;Lee, Hye-Young;Park, Sun-Hee;Park, Cheol-Beom;Kang, Jin Seok;Kang, Jong-Koo
    • Toxicological Research
    • /
    • v.30 no.4
    • /
    • pp.305-309
    • /
    • 2014
  • Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

A Study on Development of Eco-friendly Wrap using Biodegradable Resin (생분해성 수지를 이용한 환경친화성 랩 개발에 관한 연구)

  • Lim, Mi-Jin;Sim, Jae-Ho;Choi, Jong-Moon;Kim, Young-Sik
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.800-808
    • /
    • 2005
  • The compounding resin for biodegradable wrap was developed, and its manufacturing process and physical properties were studied. For these purposes, following factors were optimized: the types and amounts of raw resin material, anti-oxidants, and lubricants used. In this work, the stable compounding resin used to make biodegradable wrap was based on poly(butylene adipate-co-butylenesuccinate) (PBAS) and poly(butyleneadipate-co-butylene succinate-co-butyleneterephthalate) (PBAST). The improved properties of resin with an additive were investigated by melting flow index (MFI). From these results, the physical properties of compounding resin, based on PBAST, were more than those of PBAS. For PBAS, the Irganox 1010, 1076 and Irgafos TNPP as the first and second anti-oxidants, respectively, were good. For PBAST, the good first and second anti-oxidants, respectively, were Irganox 1076 and Mark PEP 36. The good lubricants for feeding PBAS and PBAST were glycerol monostearate and palmityl alcohol, respectively. The stability and tensile strength experiment of wrap were also investigated by the elution of heavy metals and universal testing machine (UTM), respectively. The decomposition ratio of developed wrap was increased proportional to the reclaiming time. The degradation ratio of compounding resin sample was about 60% after 40 days.

Estimation of Biomass for 27 Years Old Korean Pine (Pinus koraiensis) Plantation in Gangneung, Gangwon-Province (강릉지방 27년생 잣나무조림지의 바이오매스에 관한 연구)

  • Lee, Young-Jin;Seo, Yeon-Ok;Park, Sang-Moon;Pyo, Jung-Kee;Kim, Rae-Hyun;Son, Yeong-Mo;Lee, Kyeong-Hak;Kim, Hyung-Ho
    • Journal of agriculture & life science
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • This study was conducted to examine the biomass, allometric equations, net primary production, above and total biomass expansion factors and stem density values for 27 years old Korean pine(Pinus koraiensis Siebold et Zuccarini) plantation at the Gangneung National Forest. After considering of the diameter distributions in the $20m{\times}20m$ plot measurement, a total of 5 representative sample trees were destructively sampled to measure green weights and dry weights of the four(root, stem, branch and foliage) protions of Korean pine trees. According to the results of this study, total dry weights were 117.6 kg/tree and 59.9 ton/ha. Aboveground biomass and total (above and belowground) biomass for this species were 59.9 and 82.4 ton/ha, respectively. Ratios of root to aboveground biomass were 0.38. Net primary production of aboveground biomass and belowground biomass were 9.4 and 11.3 ton/ha, respectively. Stem density was $0.49g/cm^{3}$. Above and total biomass expansion factors were 1.78 and 2.19, repectively. This information could be very useful to calculate carbon sequestrations by applying stem desity values and biomass expansion factors for Korean pine species.

Study on the Annual Diameter Growth Characteristics for Major Species Distributed in Chungnam Province (충남지역 주요 수종에 대한 연년 직경생장량 특성에 관한 연구)

  • Seo, Yeon-Ok;Lee, Young-Jin;Park, Sang-Moon;Pyo, Jung-Kee;Jung, Jin-Hyun;Kim, Sung-Ho;Lee, Woo-Kyun;Choi, Jung-Kee;Kim, Hyung-Ho
    • Journal of agriculture & life science
    • /
    • v.43 no.3
    • /
    • pp.7-14
    • /
    • 2009
  • Some results of the 5th Korean National Forest Inventory Program measured in 2007 were used to analyze annual diameter growth characteristics for major tree species distributed in Chungnam province. A total of 717 sample trees from 49 plots distributed in Chungnam province were measured and analyzed for annual diameter growth characteristics. As stand age and stand density increased, annual diameter growth rates for major species tended to decrease. The species of Prunus sargentii(2.14mm/yr) showed the best annual diameter growth rates and the others are Quercus serrata(2.10mm/yr), Pinus thunbergii(2.03mm/yr), Pinus densiflora(1.91mm/yr), and Castanea crenata(1.90mm/yr) in order. This information could be very useful to understand annual diameter growth characteristics for major species distributed in Chungnam province.

Annual Tree Ring Growth Characteristics for Major Species in Chungbuk Province (충북지역 주요 수종의 연륜생장량 특성에 관한 연구)

  • Seo, Yeon-Ok;Lee, Young-Jin;Park, Sang-Moon;Pyo, Jung-Kee;Jeong, Jin-Hyun;Kim, Sung-Ho;Choi, Jung-Kee;Lee, Woo-Kyun;Chung, Dong-Jun;Moon, Hyun-Shik
    • Journal of agriculture & life science
    • /
    • v.43 no.6
    • /
    • pp.1-6
    • /
    • 2009
  • The purpose of this study was to analyze annual tree ring growth characteristics for major tree species distributed in Chungbuk province. A total of 800 sample trees from 56 permanent sampling plots measured by the 5th Korean National Forest Inventory Program in 2007 was used for the calculation of annual growth rates. According to the results of this study, the species of Robinia pseudoacacia(2.30mm/yr) showed the best annual tree ring growth rates and the others are Quercus serrata(2.27mm/yr)>Prunus sargentii(1.98mm/yr)> and Larix leptolepis(1.98mm/yr) in order. Most of the major tree species in Chungbuk province, as tree age and stand density increased, annual tree ring growth rates tended to decreased. This information could be very useful for forest managers to understand annual tree ring growth characteristics in Chungbuk province.

Factors Associated with the Quality of Life among Persons with Severe Mental Illness Living in Supported Housing (독립주거 거주 중증 정신장애인의 삶의 질에 영향을 미치는 요인에 관한 연구)

  • Lee, Sung-eun
    • Korean Journal of Social Welfare Studies
    • /
    • no.36
    • /
    • pp.281-299
    • /
    • 2008
  • The objective of this study was to examine the association between personal, housing, program, and service characteristics and quality of life among persons with severe mental illness living in supported housing. A cross sectional survey of a random sample of 237 clients residing in supported housing in Philadelphia was used to assess the association between personal and environmental characteristics, and quality of life. Data were collected from structured interviews, administrative data, the 2000 U.S. Census data file and the Philadelphia police crime database. Multiple regression analyses were used to identify personal and environment characteristics that are associated with quality of life. Clients with diagnoses of schizophrenia, those with lower levels of psychiatric symptoms, those with higher levels of physical health status, and those with higher levels of perceived supportiveness with staff had higher levels of quality of life. Findings of this study suggested that clients' clinical characteristics and consumer staff relationships can be important variables for understanding quality of life among supported housing residents. Factors associated with quality of life identified in this study may help service providers design and plan services to promote quality of life and stable independent living in the community of supported housing residents.

A Survey on Heavy Metal Contents and Transfer Rate in Animal Medicines (동물성 생약의 중금속 함량 및 이행률 조사)

  • Lee, Sung-Deuk;Lee, Jeong-Sook;Hwang, Kwang-Ho;Kim, Hee-Soon;Yoo, In-Sil;Han, Ki-Young;Chae, Young-Zoo
    • YAKHAK HOEJI
    • /
    • v.57 no.1
    • /
    • pp.8-17
    • /
    • 2013
  • The objective of this study is investigation of contamination levels and transfer rate of heavy metals and assessment of health risk effects in animal medicines. A total of sixteen items with 148 samples were obtained for this investigation from major herbal medicine producing areas and herbal markets from 2011 to 2012. Inductively coupled plasma mass spectrometer method was conducted for the quantitative analysis of Pb, Cd and As. In addition, the mercury analyzer system was conducted for that of Hg without sample digestion. The average contents of heavy metals in animal medicines were as follows : 1.55 mg/kg for Pb, 0.28 mg/kg for Cd, 0.70 mg/kg for As and 0.047 mg/kg for Hg respectively. The average contents of heavy metals in decoctions were as follows : 0.03 mg/kg for Pb, 0.01 mg/kg for Cd, 0.17 mg/kg for As and 0.003 mg/kg for Hg respectively. The average transfer rates of heavy metals from animal medicines to decoctions were 1.9% for Pb, 3.6% for Cd, 24.2% for As and 6.0% for Hg respectively. Cancer risks of animal medicines and decoctions through slope factor by ministry of environment republic korea and environmental protection agency was $1.36{\times}10^{-6}$ and $2.50{\times}10^{-8}$ for Pb and $7.46{\times}10^{-5}$ and $1.98{\times}10^{-5}$ for As (assuming that the total arsenic content was equal to the inorganic arsenic) respectively. The hazard index of heavy metals in animal medicines and decoctions was below recommended hazard index as 0.52 and 0.05 respectively. Taken together, cancer risks about Pb and hazard indexes of animal medicines and decoctions indicate that the majority of samples except for some samples with relative high contents of heavy metals were safe. But cancer risks about As of animal medicines indicate that the majority of samples were not relatively safe.