• 제목/요약/키워드: Environmental radiation monitor

검색결과 34건 처리시간 0.031초

저선량과 고선량 측정구간 변환이 가능한 모바일 방사선 측정시스템 개발 및 평가 (Development and Evaluation of a Mobile Environmental Radiation Measurement System That Can Switch between Low and High Dose Measurement Sections)

  • 이홍연;한상준;김보길;이건주;김석현;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.49-55
    • /
    • 2022
  • This study is to develop a mobile type environmental radiation measurement system for emergency response or environmental radiation monitoring of local governments near nuclear facilities. A mobile radiation measurement system can monitor radiation by field beyond the spatial constraints of a fixed environmental radiation monitor. If installed in local government infrastructure such as public transportation, environmental radiation can be monitored without additional manpower and measurement work. In addition, it is designed to enable monitoring and measurement of radiation from low to high doses as well as the environment in preparation for radioactive disasters such as nuclear power plant accidents. It is expected that this system will be utilized not only in normal times but also in the event of a radiation accident to improve the disaster prevention capabilities of local governments.

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

환경방사선감시기의 NaI(Tl) 검출기를 이용한 조사선량률 결정방법 (Determinations of the Exposure Rate Using a NaI(Tl) Detector of the Environmental Radiation Monitor)

  • 지영용;이완로;최상도;정근호;강문자;최근식
    • 방사성폐기물학회지
    • /
    • 제11권3호
    • /
    • pp.245-251
    • /
    • 2013
  • NaI(Tl) 섬광검출기로 측정한 에너지 스펙트럼으로부터 공간 감마 선량률을 계산하기 위하여 에너지밴드 방법과 G-factor 방법의 결과를 비교 검토하였다. 먼저 한국원자력연구원 내 운영 중인 환경방사선감시기 EFRD 3300에 장착된 3"${\Phi}X3$" NaI(Tl) 검출기의 G-factor를 MCNP 모델링을 통하여 입사 방사선의 방향에 따라 각각 구하였으며, 이로부터 계산된 선량률과 에너지밴드 방법으로 계산된 결과의 차이를 비교 검토함으로써 EFRD 3300에 적용 가능한 최적의 G-factor 값을 유도하였다. 그리고 EFRD 3300 방사선감시기가 운영되고 있는 지역 주변에 위치한 HPIC 방사선감시기의 선량률과 비교 검토를 수행하였으며, 3"${\Phi}X3$" NaI(Tl) 검출기 기반의 EFRD 3300에서 $7.7{\mu}R/h$의 측정값을 얻어 약 $3{\mu}R/h$ 정도의 차이를 보였다. 일반적으로 HPIC 방사선감시기는 고에너지 우주방사선량도 측정할 수 있는 것으로 알려져 있으므로, 이 차이는 3"${\Phi}X3$" NaI 계측기로 측정되지 못하는 고에너지 영역의 우주방사선에 의한 영향으로 평가할 수 있었다.

Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

  • Coulon, Romain;Dumazert, Jonathan;Tith, Tola;Rohee, Emmanuel;Boudergui, Karim
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1489-1494
    • /
    • 2017
  • The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe) chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl), CdZnTe, and $LaBr_3:Ce$. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

네트워크를 이용한 온실 감시 시스템의 개발 (Development of a Greenhouse Monitoring System Using Network)

  • 임정호;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • 제28권1호
    • /
    • pp.53-58
    • /
    • 2003
  • This study was carried out to design, construct, and test a greenhouse monitoring system fur the environment and status of control devices in a greenhouse from a remote site using internet. The measuring items selected out of many environmental factors were temperature, humidity, solar radiation, CO$_2$, SOx, NOx concentration, EC, pH of nutrient solution, the state of control devices, and the image of greenhouse. The developed greenhouse monitoring system was composed of the network system and the measuring module. The network system consists of the three kinds of monitors named the Croup Monitor. the Client Monitor and the Server Monitor. The results of the study are summarized as follows. 1. The measuring module named the House Monitor. which is used to watch the state of the control device and the environment of the greenhouse, was developed to a embedded monitoring module using one chip microprocessor 2. For all measuring items. the House Monitor showed a satisfactory accuracy within the range of ${\pm}$0.3%FS. The House Monitors were connected to the Croup Monitor by communication method of RS-485 type and could operate under power and communication fault condition within 10 hours. The Croup Monitor was developed to receive and display measurement data received from the House Monitors and to control the greenhouse environmental devices. 3. The images of the plants inside greenhouse were captured by PC camera and sent to the Group Monitor. The greenhouse manager was able to monitor the growth state of plants inside greenhouse without visiting individual greenhouses. 4. Remote monitoring the greenhouse environment and status of control devices was implemented in a client/server environment. The client monitor of the greenhouse manager at a remote site or other greenhouse manager was able to monitor the greenhouse environment and the state of control devices from the Server Monitor using internet.

림프구의 미소핵을 지표로 영광 원자력발전소 주변 사육 돼지의 방사선 생물학적 평가 (Radiobiological Evaluation in Pig Bred in the Vicinity of Yeonggwang Nuclear Power Station Using Micronuclei in Cytokinesis-blocked Lymphocyte)

  • 김세라;강창모;김성호
    • 한국임상수의학회지
    • /
    • 제21권3호
    • /
    • pp.286-290
    • /
    • 2004
  • Cytogenetic and hematological analysis was performed in peripheral blood of pig in the vicinity of Yeonggwang nuclear power station and control area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from pig was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the swine lymphocytes exposed in vitro to radiation over the range from 0 Gy to 4 Gy. MN rates in lymphocytes of pig from Yeonggwang nuclear power station and control area were 10.60/1,000 and 11.10/1,000, respectively. There were no significant differences in MN frequencies and hematological values in pig between Yeonggwang and control area. The study indicates that the MN assay in lymphocyte of pig is a rapid, sensitive and accurate method that can be used to monitor a large population exposed to radiation.

Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment

  • Kim, Jeong Ho;Park, Ki Hyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.801-805
    • /
    • 2018
  • In this study, an underwater radiation detector was built using a GAGG(Ce) scintillator and silicon photomultiplier to establish an underwater radiation exposure monitoring system. The GAGG(Ce) scintillator is suitable for small radiation detectors as it strongly absorbs gamma rays and has a high light emission rate with no deliquescent properties. Additionally, the silicon photomultiplier is a light sensor with characteristics such as small size and low applied voltage. Further, a program and mobile app were developed to monitor the radiation coefficient values generated from the detector. According to the results of the evaluation of the characteristics of the underwater radiation monitoring system, when tested for its responsiveness to radiation intensity and reactivity, the system exhibited a coefficient of determination of at least 0.99 with respect to the radiation source distance. Additionally, when tested for its underwater environmental temperature dependence, the monitoring system exhibited an increase in the count rate up to a certain temperature because of the increasing dark current and a decrease in the count rate because of decreasing overvoltage. Extended studies based on the results of this study are expected to greatly contribute to immediate and continuing evaluation of the degree of radioactive contamination in underwater environments.

세포질 분열 차단 림프구를 이용한 월성원자력발전소 주변 소의 미소핵 발생 평가 (Evaluation of Micronucleus Frequency in Cytokinesis-blocked Bovine Lymphocytes from Regions around Wolsong Nuclear Power Plant)

  • 김세라;김태환;김성호
    • 대한수의학회지
    • /
    • 제43권3호
    • /
    • pp.333-338
    • /
    • 2003
  • Cytogenetic and hematological analysis was performed in bovine peripheral blood from the regions around Wolsong nuclear power plant and control area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from cattle was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dare of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the bovine lymphocytes exposed in vitro to radiation over the range from 0 Gy to 4 Gy. MN rates in lymphocytes of cattle from Wolsong nuclear power plant and control area were 9.87/1,000 and 9.60/1,000, respectively. There were no significant differences in MN frequencies and hematological values in cattle between Wolsong and control area. The study indicates that the MN assay is a rapid, sensitive and accurate method that can be used to monitor a large population exposed to radiation.

KAERI 부지 주변의 환경선량 측정을 위한 온라인 감마선량 감시시스템 (On-line Gamma Monitoring System for Environmental Radiation Measurement around KAERI-site)

  • 이창우;박두원;이원유;최용호;홍광희;김삼랑;이현덕;이정호
    • Journal of Radiation Protection and Research
    • /
    • 제19권2호
    • /
    • pp.147-156
    • /
    • 1994
  • 환경감마선량 변동을 감시하기 위해 한국원자력연구소 부지 주변에 온라인 감마선량 감시망을 구성하였다. 모니터링 포스트에 설치된 전리함 검출기에 의해 측정된 자료는 무선전송 방식으로 중앙동제소에 전송되어 실시간으로 감시된다. 무선전송 방식은 자료의 전송, 처리 및 저장에 신뢰도가 높고 경제적이었다. 감시시스템은 급격한 선량증가시 조기경보체제와 연결할 수 있게 하였다.

  • PDF