• Title/Summary/Keyword: Environmental loading ratio

Search Result 378, Processing Time 0.034 seconds

The Treatment of Volatile Organic Compounds Using a Pilot-Scale Biofilter (Pilot 규모의 바이오필터를 이용한 휘발성유기화합물질 제거)

  • Son, Hyun-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.245-252
    • /
    • 2004
  • Two biofilter tests were conducted under different operating conditions. Test # 1 was performed to treat VOCs generated from a paint booth. The second test was performed to treat VOCs generated from chemical manufacturing processes. The volume of biofilter media was 4.3 $m^3$. For the test # 1, the biofilter was operated for 30 days with 99.9% reduction ratio. Range of temperature of each stage of the biofilter media was measured between $34^{\circ}C$ and $73^{\circ}C$. All the temperatures of stages reduced gradually after the initial dramatic increase. For the test # 2, the biofilter experiment was conducted for 14 days. In this case, the biofilter was installed outdoor and the experiment was performed during wintertime. Therefore, temperature management for the biofilter was needed. Seven-centimeter thick fiberglass insulation and $150^{\circ}C$ steam heating were used to overcome the outside freezing cold weather during test # 2. Temperature of stage # 5 was measured the highest and that of stage # 1 was the lowest. More acclimation time and test period was needed to determine the maximum loading rate.

Pretreatment of Corn Stover for Improved Enzymatic Saccharification using Ammonia Circulation Reactor (ACR) (순환식 암모니아 반응기(Ammonia Circulation Reactor (ACR))를 이용한 옥수수대의 전처리 및 효소 당화율 향상)

  • Shrestha, Rubee Koju;Hur, Onsook;Kim, Tae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.335-341
    • /
    • 2013
  • Ammonia circulation reactor (ACR) was devised for the effective pretreatment of corn stover. This method is designed to circulate aqueous ammonia continuously so that it can reduce the chemical and water consumption during pretreatment. In this study, ammonia pretreatment with various reaction conditions such as reaction time (4~12 hour), temperature ($60{\sim}80^{\circ}C$), and solid:liquid ratio (1:3~1:8) was tested. Chemical compositions including solid remaining after reaction, lignin and carbohydrates were analyzed and enzymatic digestibility was also measured. It was observed that as reaction conditions become more severe, lignin removal was significantly affected, which was in the range of 47.6~70.6%. On the other hands, glucan and xylan losses were not substantial as compared to that of lignin. At all tested conditions, the glucan loss was not changed substantially, which was between 4.7% and 15.2%, while the xylan loss varied, which was between 7.4% and 25.8%. With (15 FPU-GC220+30 CBU)/g-glucan of enzyme loading, corn stover treated using ammonia circulation reactor for 8~12 hours resulted in 90.1~94.5% of 72-h glucan digestibility, which was higher than 92.7% of $Avicel^{(R)}$-101. In addition, initial hydrolysis rate (at 24 hour) of this treated corn stover was 73.0~79.4%, which was shown to be much faster than 69.5% of $Avicel^{(R)}$-101. As reaction time increased, more lignin removal and it was assumed that the enhanced enzymatic digestibility of treated biomass was attributed to the lignin removal.

Evaluation of Permanent Lateral Displacement of a Cyclic Laterally Loaded Pile in Sandy Soil (모래지반에서 횡방향 반복하중을 받는 말뚝의 영구수평변위 평가)

  • Baek, Sung-Ha;Kim, Joon-Young;Lee, Seung-Hwan;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.2
    • /
    • pp.17-26
    • /
    • 2017
  • Pile foundations that support offshore structures or transmission towers are dominantly subjected to cyclic lateral loads due to wind and waves, causing permanent displacement which can severely affect stability of the structures. In this study, a series of cyclic lateral load tests were conducted on a pre-installed aluminum flexible pile in sandy soil with three different relative densities (40%, 70% and 90%) in order to evaluate the permanent displacement of a cyclic laterally loaded pile. Test results showed that the cyclic lateral loads accumulated the irreversible lateral displacement, so-called permanent displacement. As the number of cyclic lateral load increased, accumulated permanent displacement increased, but the permanent displacement due to one loading cycle gradually decreased. In addition, the permanent displacement of a pile increased with decrement of relative density and decreased by soil saturation. From the test results, the normalized permanent displacement defined as the cumulative permanent displacement to the initial permanent displacement ratio was investigated, and empirical equations for predicting the normalized permanent displacement was developed in terms of relative density of the soil and the number of cyclic lateral load.

Corrosion Behavior and Ultrasonic Velocity in RC Beams with Various Cover Depth (다양한 피복두께를 가진 RC 보의 부식 거동 및 초음파 속도)

  • Jin-Won Nam;Hyun-Min Yang;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.184-191
    • /
    • 2023
  • With increasing corrosion in RC (Reinforced Concrete) structures, cracks occurred due to corrosion products and bearing load resistance decreased. In this study, corrosion was induced through an accelerated corrosion test (ICM: Impressed Current Method) with 140 hours of duration, and changes in USV (Ultra-Sonic Velocity), flexural failure load, and corrosion weight were evaluated before and after corrosion test. Three levels of cover depth (20 mm, 30 mm, and 40 mm) were considered, and the initial cracking period increased and the rust around steel decreased with increasing cover depth. In addition, the USV linearly decreased with decreasing cover depth and increasing amount of corrosion. In the flexural loading test, the bending capacity decreased by more than 10% due to corrosion, but a clear correlation could not be obtained since the corrosion ratio was small, so that the effect of slip was greater than that of reduced cross-sectional area of steel due to corrosion. As cover depth increased, the produced corrosion amount and USV changed with a clear linear relationship, and the cracking period due to corrosion could be estimated by the gradient of the measured corrosion current.

Anaerobic Ammonium Oxidation(ANAMMOX) in a Granular Sludge Reactor and its Bio-molecular Characterization (입상 슬러지 반응조 내의 혐기성 암모늄 산화(ANAMMOX) 및 분자생태학적 특성 평가)

  • Han, Ji-Sun;Park, Hyun-A;Sung, Eun-Hae;Kim, Chang-Gyun;Yoon, Cho-Hee;Bae, Young-Shin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1213-1221
    • /
    • 2006
  • In this study, granular sludge used in an anaerobic process treating brewery waste was inoculated in a laboratory scale of reactor to induce anaerobic ammonium oxidation(ANAMMOX). The reactor was operated with synthetic wastewater, which prepared at 1:1 ratio of $NH_4^+-N$ over $NO_2^--N$. Changes in nitrogen concentration, COD, alkalinity and gas production were analyzed. There are 3 phases of spanning in experimental period according to influent nitrogen concentration. In the Phase 1, each of the concentration of $NH_4^+-N$ and $NO_2^--N$ were increased from 1.91 $gN/m^3{\cdot}d$ to 14.29 $gN/m^3{\cdot}d$. Ammonium nitrogen loading(same as nitrite nitrogen) was 23.81 $gN/m^3{\cdot}d$ in the Phase 2 and 19.05 $gN/m^3{\cdot}d$ in the Phase 3, respectively $NO_2^--N$ has been removed up to 99% during whole period while the removal efficiency of $NH_4^+-N$ was significantly varied. In Phase 2, $NH_4^+-N$ was removed up to 75%. Microorganisms varied temporally through three phases were characterized by 16s rDNA analysis methods. ANAMMOX bacteria were dominantly found in phase 2 when the removal rate of $NO_2^--N$and $NH_4^+-N$ was the highest up to 99% and 75%, respectively. Due to erroneous exposed to air, the removal efficiency of $NH_4^+-N$ was unexpectedly lowered, but ANAMMOX bacteria still existed.

A Study on the Characteristics of PM1.0 Chemical Components Using a Real-time Aerosol Mass Spectrometer (실시간 에어로졸 질량분석기를 이용한 PM1.0의 화학적성분의 특성에 관한 연구)

  • Park, Jinsoo;Choi, Jinsoo;Kim, Hyunjae;Oh, Jun;Sung, Minyoung;Ahn, Joonyoung;Lee, Sangbo;Kim, Jeongho
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.485-494
    • /
    • 2018
  • This study aims to identify the characteristics of oxidation and chemical composition of PM in winter season, 2017 at Incheon area. The mean concentration of air pollutants were $46{\pm}22{\mu}g/m^3-PM_{10}$, $29{\pm}18{\mu}g/m^3/-PM_{2.5}$, $5{\pm}3ppb-SO_2$, $0.56{\pm}0.24ppm-CO$, $21{\pm}13ppb-O_3$ and $28{\pm}17ppb-NO_2$, respectively. The dominant ion of the $PM_{1.0}$ chemical component were organic with $3.2{\mu}g/m^3$ and nitrate with $1.9{\mu}g/m^3$. The day and night variation of the $PM_{1.0}$ chemical components was higher in nighttime than those of daytime. The averaged nitrate oxidation rate (SOR) was 0.06 and sulfate oxidation rate was 0.11 during the field campaign. In the high mass loading period, nitrate oxidation rate (NOR) was up to 0.6 and also the nitrate in $PM_{1.0}$ was increased. The averaged ratio of $NO_x/SO_2$ was 8.7 and nitrate/sulfate was 3.1, respectively. In this results, the nitrate component in $PM_{1.0}$ was influenced by NOx from the stationary source as power plant and the mobile source around the measurement site.

Application of MODIS Aerosol Data for Aerosol Type Classification (에어로졸 종류 구분을 위한 MODIS 에어로졸 자료의 적용)

  • Lee, Dong-Ha;Lee, Kwon-Ho;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.6
    • /
    • pp.495-505
    • /
    • 2006
  • In order to classify aerosol type, Aerosol Optical Thickness (AOT) and Fine mode Fraction (FF), which is the optical thickness ratio of small particles$(<1{\mu}m)$ to total particles, data from MODIS (MODerate Imaging Spectraradiometer) aerosol products were analyzed over North-East Asia during one year period of 2005. A study area was in the ocean region of $20^{\circ}N\sim50^{\circ}N$ and $110^{\circ}E\simt50^{\circ}E$. Three main atmospheric aerosols such as dust, sea-salt, and pollution can be classified by using the relationship between AOT and FF. Dust aerosol has frequently observed over the study area with relatively high aerosol loading (AOT>0.3) of large particles (FF<0.65) and its contribution to total AOT in spring was up to 24.0%. Pollution aerosol, which is originated from anthropogenic sources as well as a natural process like biomass burning, has observed in the regime of high FF (>0.65) with wide AOT variation. Average pollution AOT was $0.31{\pm}0.05$ and its contribution to total AOT was 79.8% in summer. Characteristic of sea-salt aerosol was identified with low AOT (<0.3), almost below 0.1, and slightly higher FF than dust and lower FF than pollution. Seasonal analysis results show that maximum AOT $(0.33{\pm}0.11)$ with FF $(0.66{\pm}0.21)$ in spring and minimum AOT $(0.19{\pm}0.05)$, FF $(0.60{\pm}0.14)$ in fall were observed in the study area. Spatial characteristic was that AOT increasing trend is observed as closing to the eastern part of China due to transport of aerosols from China by the prevailing westerlies.

A Program of Water Quality Management for Agricultural Reservoirs by Trophic State (농업용 저수지의 부영양화와 수질관리방안)

  • Lee, Kwang-Sik;Yoon, Kyung-Sup;Kim, Ho-Il;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.166-171
    • /
    • 2003
  • A total of 498 agricultural reservoirs ranging from $164{\times}10^3\;m^3$ to $253{\times}10^6\;m^3$ in storage volume were investigated from 1990 to 2001 with respect to Chl-${\alpha}$, COD concentration and pollutant loading of BOD, TN, and TP. The lakes and reservoirs could be classified to 4 types using the relationships between the ratio of storage volume per water surface area(ST/WS) and Chl-${\alpha}$ concentration. It is recommended that the improvement of polluted lakes should be performed in the order of integrated consolidation type ${\rightarrow}$ watershed consolidation type ${\rightarrow}$ in-lake consolidation type ${\rightarrow}$ Management type and reservoir should be constructed to be over $5{\sim}6\;m$ in depth(ST/WS ratio) for preventing the eutrophication of agricultural reservoirs. We propose that water quality criteria for agricultural water is changed from less than 8 mg/L to less than 6 mg/L for safety value, $6{\sim}10\;mg/L$ for concern value, and more than 10 mg/L for countermeasure value in COD concentration, respectively.

Developments of Water Treatment System by Biological Fluidized Bed for Water Reuse Aquaculture (생물학적 유동층을 이용한 어류양식 순환수의 처리씨스템 개발)

  • LEE Ki-Wan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.4
    • /
    • pp.380-391
    • /
    • 1993
  • The experimental study was made to propose the treatment method of wastewater in the high-density fish culture system. The BOD to COD ratios of effluents were almost same to 0.65 in the eel-farm, but were various in the farm rearing together with tilapia etc. A BOD rate curve of the eel-farm effluent could be described mathematically by the equation, $BODu=14.1(1-10^{-0.222t})+30.9(1-10^{-0.035(t-8)})$. Nitrification in Biological Fluidized Bed(BFB) system to treat the fish-farm wastewater could be reduce ammonium level up to $65{\sim}79\%$ when ammonium loading rates were between 0.014 and 0.075g $NH_4/g$ BVS-day. Nitrification efficiency was decreased by organic matters in the wastewater when ammonium loading was low(0.014 g $NH_4/g$ BVS-day). T-N removal ratios were decreased to increase loading in denitrification process, because of low C/N ratio. Based on much higher biological mass concentrations, BFB system takes many advantages of a practical viewpoint, such as stability of treatment efficiency and reduction of necessary site area for the facility, as compared with conventional treatment systems.

  • PDF

Kinetics of esterification of food waste oil by solid acid catalyst and reaction optimization (고체 산 촉매를 이용한 고산가 음폐유의 에스테르화 반응 동역학 연구 및 반응 최적화)

  • Lee, Hwa-Sung;Lee, Joon-Pyo;Lee, Jin-Suk;Kim, Deog-Keun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.683-693
    • /
    • 2017
  • Transport biofuels have been recognized as a promising means to resolve the following issues like global warming, oil depletion and environmental pollutions. Among various biofuels, biodiesel has several advantages such as less emission of air pollutants and higher cetane values compared to diesel oil. Demand for biodiesel in Korea is increasing that leads to higher dependence on the imported feedstocks. Therefore, it is important to utilize the waste materials collected domestically for biodiesel production. Food waste oil collected in waste treatment facility has not been used for biodiesel production due to high free fatty contents in the oil. In this work, biodiesel conversion of food waste oil by Amberlyst 15 was studied. Synthetic and actual food waste oils have been used in the study. First, the effects of the major operating parameters including reaction temperature, methanol to oil molar ratio and catalyst loading on the conversion rates and yields were determined with synthetic waste oil. Kinetic modelling work was also done to determine the activation energy of the reaction. From the work, optimization reaction conditions were determined to be 383K, 1: 26.1 for methanol molar ratio to oil, 10 wt.% for catalyst loading and 360 min for reaction time. Activation energy of the reaction is determined to be 29.75 kJ/mol, lower than those reported in the previous works. So the solid catalyst, Amberlyst 15, was more efficient for esterification than the solid catalysts employed in the other works. Agitation rates have the negligible effects on the conversion rates and yields. With the identified optimization conditions, conversion of the actual food waste oil was also carried out. The esterification yield of actual food waste oil in 60 min was 13% lower than that of synthetic waste oil but the final yields in 240 min were similar each other, 98.12% for synthetic oil and 97.62% for actual waste oil.