• Title/Summary/Keyword: Environmental load

Search Result 3,421, Processing Time 0.032 seconds

Effects of Deletion of Supplementary Vitamins and Trace Minerals on Performance, Muscle Vitamin E and Fecal Trace Mineral Contents in Finishing Pigs (비육후기 사료에서 비타민-미량광물질 첨가제의 제거가 돼지의 성장 능력, 근육 내 비타민 E 및 분 중 미량광물질 함량에 미치는 영향)

  • Lee, S.C.;Lee, C.E.;Kim, K.I.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.543-550
    • /
    • 2003
  • Two experiments were conducted to determine the effects of deletion of vitamin and trace mineral premixes on growth, feed efficiency, backfat thickness, hemoglobin content, muscle vitamin E content, and fecal, serum and muscle trace mineral contents in finishing pigs raised under two different housing conditions. In Exp. 1, three pens (or experimental units) of five pigs each (average weight $\pm$ s.e., 70 $\pm$ 0.5 kg) were assigned to a control diet (with vitamin and trace mineral premixes) or diets with 50 or 100% of the premixes deleted. Pigs were fed to market weight under sub-optimal housing conditions with sawdust-covered concrete floor and no electrical ventilation. In Exp. 2, three pens of four pigs each (average weight $\pm$ s.e., 56 $\pm$ 1.1 kg) were assigned to a control (with vitamin and trace mineral premixes), Diet-P (100% of the premixes deleted) or Diet-P+E (Diet-P plus 100 mg $\alpha$-tocopherol acetate/kg diet fed for the last 2 wk before slaughter). Pigs were fed to market weight under optimal housing conditions with 70%-slatted concrete floor, electrical ventilation and temperature control. No significant differences were found in average daily gain (ADG), average daily feed intake (ADFI), and gain/feed among treatments in both experiments, but in Exp. 2 done with younger pigs, ADG and ADFI tended to be higher in the control group than in pigs fed diet without premixes. Hemoglobin content, hematocrit and red blood cell count were not influenced by the deletion of premixes. Backfat thickness was not different among treatments. Fecal Mn (twofold) and Zn (threefold) contents were higher in the control than in pigs fed diets without the premixes. Serum trace mineral contents were not influenced by diets. $\alpha$-Tocopherol content in gluteus maxima was decreased (P< 0.01) by deleting the dietary premixes, but increased to the level higher than the control by adding 100 mg $\alpha$-tocopheryl acetate/kg diet fed for the last 2 wk before slaughter. Results indicate that: 1) supplementary vitamins and trace minerals may not be necessary for optimum growth in finishing pigs, and 2) deletion of the dietary premixes reduces muscle vitamin E content, but the reduced content can be reversed by adding $\alpha$- tocopherol to diets fed for the last 2 wk before slaughter. The deletion may help to alleviate the environmental load of certain minerals from manure.

Photocatalytic Treatment of Waste Air Containing Malodor and VOC by Photocatalytic Reactor Equipped with the Cartridges Containing the Media Carrying Photocatalyst (광촉매 카트리지를 활용한 악취 및 VOC를 함유한 폐가스의 광촉매처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.80-86
    • /
    • 2013
  • In this study, the photocatalytic reactor system equipped with photocatalyst-carrying-silica-media cartridges [photocatalytic reactor system (1)] was used to perform the treatment of waste air containing malodor and volatile organic compound (VOC). The result of its performance was evaluated and compared with that of the photocatalytic reactor system equipped with commercial photocatalyst-carrying-nonwoven filter-media cartridges [photocatalytic reactor system (2)]. In case of photocatalytic reactor system (1), at the 1st stage of run the removal efficiencies of ethanol and toluene continued to be 80% and 20%, respectively. However, unlike toluene, the removal efficiency of ethanol dropped to 40% at the end of the 1st stage of run. The removal efficiency of hydrogen sulfide decreased from 100% to 90%. At the 2nd stage of its run the removal efficiency of ethanol decreased to 10% while the removal efficiencies of hydrogen sulfide and toluene remained as same as 90% and 20%, respectively, even though the inlet load of toluene increased by factor of four. In the 3rd stage of its run, as the result of application of aluminium-coated reflector film to the inner wall of photocatalytic reactor system, the removal efficiencies of ethanol and toluene increased by 5% to be 15% and 25%, respectively. In case of photocatalytic reactor system (2), at the 1st stage of its run, the removal efficiencies of ethanol, hydrogen sulfide and toluene continued to be 10%, 97% and 100%, respectively. However, at 2nd stage of its run their removal efficiencies became 5%, 95% and 2~3%, respectively, which showed that the removal efficiencies of ethanol and hydrogen sulfide decreased insignificantly while the removal efficiency of toluene dropped significantly from the perfect elimination. Moreover, the reflector film did not affect the performance of photocatalytic reactor system (2) at all. Therefore the removal of ethanol, hydrogen sulfide and toluene by photocatalytic reactor system (2) was mainly attributed to hydrophobic adsorption of its nonwoven filter media and its extent of photocatalytic removal turned out to be negligible, compared to that of photocatalytic reactor system (1).

Reliability Based Stability Analysis and Design Criteria for Reinforced Concrete Retaining Wall (신뢰성(信賴性) 이론(理論)에 의한 R.C.옹벽(擁壁)의 안정해석(安定解析) 및 설계규준(設計規準))

  • Cho, Tae Song;Cho, Hyo Nam;Chun, Chai Myung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.71-86
    • /
    • 1983
  • Current R.C. retaining wall design is bared on WSD, but the reliability based design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the cantilever retaining wall, which is most common type of retaining wall, and also proposes the theoretical bases of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis and design of each part of cantilever retaining wall are derived and the uncertainty measuring algorithms of each equation are also derived by MFOSM using Coulomb's coefficient of the active earth pressure and Hansen's bearing capacity formula. The levels of uncertainties corresponding to these algorithms are proposed appropriate values considering our actuality. The target reliability indices (overturning: ${\beta}_0$=4.0, sliding: ${\beta}_0$=3.5, bearing capacity: [${\beta}_0$=3.0, design for flexure: [${\beta}_0$=3.0, design for shear: ${\beta}_0$=3.2) are selected as optimal values considering our practice based on the calibration with the current R.C. retaining wall design safety provisions. Load and resistance factors are measured by using the proposed uncertainties and the selected target reliability indices. Furthermore, a set of nominal safety factors, allowable stresses, and allowable shear stresses are proposed for the current WSD design provisions. It may be asserted that the proposed LRFD reliability based design criteria for the R.C. retaining wall may have to be incorporated into the current R.C. design codes as a design provision corresponding to the USD provisions of the current R.C. design code.

  • PDF

Environmental Impact Assessment by Marine Cage Fish Farms: II. Estimation of Hydrogen Sulfide Oxidation Rate at $O_2$-H$_2$S Interface and Sulfate Reduction Rate in Anoxic Sediment Layer (해상 어류가두리양식장의 환경영향 평가: II. 가두리 양식장 퇴적물의 산소-황화수소 경계면에서 황화수소의 산화율 및 무산소 퇴적층에서 황산염 환원율 추정)

  • Lee, Jae-Seong;Kim, Kee-Hyun;Yu, Jun;Lee, Pil-Yong;Jung, Rae-Hong;Lee, Wong-Chan;Han, Jung-Jee;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.64-72
    • /
    • 2004
  • We measured the vertical profiles of $O_2$, H$_2$S, and pH in sediment pore water beneath marine cage fish farms using a microsensor with a 25 ${\mu}{\textrm}{m}$ sensor tip size. The sediments are characterized by high organic material load. The oxygen consumption, hydrogen sulfide oxidation, and sulfate reduction rates in the microzonations (derived from the vertical distribution of chemical species concentration) were estimated by adapting a simple one-dimensional diffusion-reaction model. The oxygen penetration depth was 0.75 mm. The oxic microzonations were divided into upper and lower layers. Due to hydrogen sulfide oxidation within the oxic zone, the oxygen consumption rate was higher in the lower layer. The total oxygen consumption rate integrated with reaction zone depth was estimated to be 0.092 $\mu$mol $O_2$cm$^{-2}$ hr$^{-1}$ . The total hydrogen sulfide oxidation rate occurring within 0.7 mm thickness was estimated to be 0.030 $\mu$mo1 H$_2$S cm$^{-2}$ hr$^{-1}$ , and its turnover time in the oxic sediment layer was estimated to be about 2 minutes. This suggests that hydrogen sulfide was oxidized by both chemical and microbial processes in this zone. The molar consumption ratio, calculated to be 0.84, indicates that either other electron accepters exit on hydrogen sulfide oxidation, or elemental sulfur precipitation occurs near the $O_2$- H$_2$S interface. Total sulfate reduction flux was estimated to be 0.029 $\mu$mol cm$^{-2}$ hr$^{-1}$ , which accounted for more than 60% of total $O_2$ consumption flux. This result implied that the degradation of organic matter in the anoxic layer was larger than in the oxic layer.

Evaluation of Worker's Health and Occupational Exposure to Perchloroethylene in Laundries (Perchlotoethylene을 사용하는 세탁소 작업자들의 직업성 폭로와 건강에 관한 연구)

  • An, Sun-Hee;Lee, Jong-Hwoa;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.224-239
    • /
    • 1994
  • In this study we examined several subjective symptoms in an exposed group and an unexposed group to perchloroethylene. The exposed group consists to 30 workers employed in 23 dry-cleaning establishments located in Chung Cheung Do, whereas the unexposed group consists of 42 officers employed in a certain university. This study was conducted from October, 1993 to March, 1994. Also we investigated personal exposure levels and area concentration of PCE, and performed hematological and biochemical examination in blood and urine samples from the exposed group. The results are : 1. The exposed group highly complains several subjective symptoms, particularly in neuropsychiatry, eye, respiratory system and digestive system, compared with the unexposed group. But complaint rates in the exposed group are not related with PCE exposure levels. 2. PCE exposure levels for all dry-cleaning establishment varied widely, from 0.18 to 37.58ppm. The mean exposure level for centers of chain was 16.85ppm, and for local laundries was 8.83ppm, while for self-service establishment it was 3.07ppm. Eighty three percent of the workers were exposed less than the half-level(25.0ppm) of the Korea 50.0ppm standard for eight-hour PCE exposure. Seventeen percent of them exceeded the half-level of the Korea TLV. 3. Statistical correlation exists between the work load(number of operation cycles of equipment and the mass of processed textiles) and the personal exposure levels to be observed. 4. In hematological examination the values of WBC, RBC, Hgb, Hct, MCV, MCH, MCHC and PLT in the exposed group were within normal ranges. In biochemical examination(GOT, GPT, ALP, U-A and LDH) most of the items were within normal ranges. From this surveys conducted on 23 dry-cleaning establishments, the complaint rates of the exposed group to PCE in several subjective symptoms were higher than those of the unexposed group, and PCE exposure levels in all dry-cleaning establishment were below the Koera standard 50.0ppm. In hematological and biochemical examination the significant abnormalities by occupational exposure to PCE were not observed. However, the workers employed in dry-cleaning establishments are always faced with risk, becauses they are also exposed to several organic solvents used to remove stains. Therefore, various measures to improve occupational environment in dry-cleaning establishment should be considered.

  • PDF

Middle school Home Economics teachers' perception and actual performance of self-supervision at school related to Home Economics (중학교 가정과 교사의 교과 관련 교내 자율장학에 대한 인식과 실태)

  • Go, Mi-Young;Chae, Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.22 no.4
    • /
    • pp.91-107
    • /
    • 2010
  • The purpose of this study was to investigate what middle school Home Economics(HE) teachers perceive, practice and need for self-supervision at school related to HE. Questionnaires were sent by E-mail and 150 were collected. Descriptive statistics including frequency, percentage, average, standard deviation, t-test and ANOVA analysis were reported using SPSS/win 10.1. The results of this research were as follows: First, middle school HE teachers perceived that self-supervision at school was essential since it promoted self reflection of teachers themselves and improved professional skills. Furthermore, peer-coaching was highly preferred. Second, negative responses to the supervision of principal, vice-principal, and peer teachers overwhelmed positive answers. Information exchange among peer teachers was frequent, yet, approximately 22.6% of middle school HE teachers were still avoiding sharing information process for several reasons. About half of the teachers answered that all teachers needed to participate in this process. Third, they pointed out that self-supervision at school was not implemented well because of the lack of time due to the heavy work load, negative and passive attitude for the improvement of teaching-learning activities, administration-centered supervision that did not reflect teachers' opinion, and shortage of economical, and environmental support.. HE teachers perceived that peer teachers who were doing good practices were most helpful for the supervision. Also, they preferred self-evaluation at the end of the self-supervision at school. Forth, to improve self-supervision at school, there were very high demands for reduction of administrative work, additional time, fundamental philosophy toward HE education. Fifth, the purpose and detailed plans of self-supervision were recognized as the results that were democratically derived by the HE teachers. Sixth, class inspection and informal inspection were operated once in a year, and self-training was rarely operated. Peer coaching and self-coaching were operated occasionally. Self-coaching and peer coaching were reported as the most helpful types of supervision. In addition, HE teachers answered that supervision was helpful to teaching method followed by contents, evaluation, and philosophy of education.

  • PDF

An Investigation of Reliability and Safety Factors in RC Flexural Members Designed by Current WSD Standard Code (현행(現行) 허용응력설계법(許容應力設計法)으로 설계(設計)되는 RC 휨부재(部材)의 신뢰성(信賴性)과 안전율(安全率) 고찰(考察))

  • Shin, Hyun Mook;Cho, Hyo Nam;Chung, Hwan Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.33-42
    • /
    • 1981
  • Current standard code for R.C. design consists of two conventional design parts, so called WSD and USD, which are based on ACI 318-63 and 318-71 code provisions. The safety factors of our WSD and USD design criteria which are taken primarily from ACI 318-63 code are considered to be not appropriate compared to out country's design and construction practices. Furthermore, even the ACI safety factors are not determined from probabilistic study but merely from experiences and practices. This study investigates the safety level of R.C. flexural members designed by the current WSD safety provisions based on Second Moment Reliability theory, and proposes a rational but efficient way of determining the nominal safety factors and the associated flexural allowable stresses of steel bars and concretes in order to provide a consistent level of target reliability. Cornell's Mean First-Order Second Moment Method formulae by a log normal transformation of resistance and load output variables are adopted as the reliability analysis method for this study. The compressive allowable stress formulae are derived by a unique approach in which the balanced steel ratios of the resulting design are chosen to be the corresponding under-reinforced sections designed by strength design method with an optimum reinforcing ratio. The target reliability index for the safety provisions are considered to be ${\beta}=4$ that is well suited for our level of construction and design practices. From a series of numerical applications to investigate the safety and reliability of R.C. flexural members designed by current WSD code, it has been found that the design based on WSD provision results in uneconomical design because of unusual and inconsistent reliability. A rational set of reliability based safety factors and allowable stress of steel bars and concrete for flexural members is proposed by providing the appropriate target reliability ${\beta}=4$.

  • PDF

Channel Changes and Effect of Flow Pulses on Hydraulic Geometry Downstream of the Hapcheon Dam (합천댐 하류 하천지형 변화 예측 및 흐름파가 수리기하 변화에 미치는 영향)

  • Shin, Young-Ho;Julien, Pierre Y.
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.579-589
    • /
    • 2009
  • Hwang River in South Korea, has experienced channel adjustments due to dam construction. Hapcheon main dam and re-regulation dam. The reach below the re-regulation dam (45 km long) changed in flow regime, channel width, bed material distribution, vegetation expansion, and island formation after dam construction. The re-regulation dam dramatically reduced annual peak flow from 654.7 $m^3$/s to 126.3 $m^3$/s and trapped the annual 591 thousand $m^3$ of sediment load formerly delivered from the upper watershed since the completion of the dam in 1989. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that non-vegetated active channel width narrowed an average of 152 m (47% of 1982) and non-vegetated active channel area decreased an average of 6.6 km2 (44% of 1982) between 1982 and 2004, with most narrowing and decreasing occurring after dam construction. The effects of daily pulses of water from peak hydropower generation and sudden sluice gate operations are investigated downstream of Hapcheon Dam in South Korea. The study reach is 45 km long from the Hapcheon re-regulation Dam to the confluence with the Nakdong River. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that the non-vegetated active channel width narrowed an average of 152 m (47% reduction since 1982). The non-vegetated active channel area also decreased an average of 6.6 $km^2$ (44% reduction since 1982) between 1982 and 2004, with most changes occurring after dam construction. The average median bed material size increased from 1.07 mm in 1983 to 5.72 mm in 2003, and the bed slope of the reach decreased from 0.000943 in 1983 to 0.000847 in 2003. The riverbed vertical degradation is approximately 2.6 m for a distance of 20 km below the re-regulation dam. It is expected from the result of the unsteady sediment transport numerical model (GSTAR-1D) steady simulations that the thalweg elevation will reach a stable condition around 2020. The model also confirms the theoretical prediction that sediment transport rates from daily pulses and flood peaks are 21 % and 15 % higher than their respective averages.

Sewage Treatment Using a Double Media Reed Constructed Wetland (복층여재 갈대 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.379-388
    • /
    • 2014
  • A sewage was treated using a serially combined vertical(VFCW) and horizontal flow double media (sand and zeolite for VFCW and sand and waste oyster-shell for HFCW) reed constructed wetland(HFCW) with intermittent feeding (see Fig. 1). The sewage was fed into the reed constructed wetland for 10 minutes every 6 hours at the hydraulic load of $314L/m^2{\cdot}day$. The summarized results were as follows: pH values in the effluent depended very heavily on oyster-shell height filled in the HFCW. They were maintained at less than pH 6.24 when the height of the oyster-shell layer was 200 mm. Influent DO(oxygen demand) values(average 0.19 mg/L) were increased in the VFCW(average 7.65 mg/L) and decreased again in the HFCW(average 6.49 mg/L). They were higher in the winter than in the summer. The OTR(oxygen transfer rate) was $57.15g\;O_2/m^2{\cdot}day$ in the VFCW and $5.65g\;O_2/m^2{\cdot}day$ in the HFCW. The removal efficiency of $NH_4{^+}$-N was 80.17%(6.01 $NH_4{^+}$-N mg/L in the effluent). It was lower than that in the case where only zeolite was filled in the reed constructed wetland. But it was expected that treated sewage effluent using a double media reed constructed wetland with 300 mm zeolite layer could stably meet the Korean treated sewage effluent standard(20 mg T-N/L). Average removal efficiencies were SS 88.09%, BOD 88.12%, $COD_{Cr}$ 83.11%, $COD_{Mn}$ 85.58%, T-N 57.21%, $NH_4{^+}$-N 80.17%, T-P 86.73%. Nearly, The concentration of $NO_3{^-}$-N in the effluent of the VFCW was decreased in that of the HFCW. More than half of T-N in the effluent was $NO_3{^-}$-N(7.92 mg/L) but the concentration of $NO_2{^-}$-N in the effluent was average 0.90 mg/L. The removal efficiencies of T-P were 93.24%, 86.30% and 55.44% at the height of the oyster-shell-filled constructed wetland of 800 mm, 500 mm and 200 mm, respectively and therefore, they were proportional to oyster-shell height filled in the HFCW.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.