• 제목/요약/키워드: Environmental capacity

검색결과 3,953건 처리시간 0.034초

Numerical and experimental analysis on the axial compression performance of T-shaped concrete-filled thin-walled steel

  • Xuetao Lyu;Weiwei Wang;Huan Li;Jiehong Li;Yang Yu
    • Steel and Composite Structures
    • /
    • 제50권4호
    • /
    • pp.383-401
    • /
    • 2024
  • The research comprehensively studies the axial compression performance of T-shaped concrete-filled thin-walled steel tubular (CTST) long columns after fire exposure. Initially, a series of tests investigate the effects of heating time, load eccentricity, and stiffeners on the column's performance. Furthermore, Finite Element (FE) analysis is employed to establish temperature and mechanical field models for the T-shaped CTST long column with stiffeners after fire exposure, using carefully determined key parameters such as thermal parameters, constitutive relations, and contact models. In addition, a parametric analysis based on the numerical models is conducted to explore the effects of heating time, section diameter, material strength, and steel ratio on the axial compressive bearing capacity, bending bearing capacity under normal temperature, as well as residual bearing capacity after fire exposure. The results reveal that the maximum lateral deformation occurs near the middle of the span, with bending increasing as heating time and eccentricity rise. Despite a decrease in axial compressive load and bending capacity after fire exposure, the columns still exhibit desirable bearing capacity and deformability. Moreover, the obtained FE results align closely with experimental findings, validating the reliability of the developed numerical models. Additionally, this study proposes a simplified design method to calculate these mechanical property parameters, satisfying the ISO-834 standard. The relative errors between the proposed simplified formulas and FE models remain within 10%, indicating their capability to provide a theoretical reference for practical engineering applications.

양방향말뚝재하시험의 재하용량 기준 설정을 위한 사례분석 연구 (A study on case analysis for loading capacity standard establishment of bi-directional pile load test (BD PLT))

  • 최용규;서정혜;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.377-384
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load test of Mega foundation, loading capacity specification were not specified exactly. Therefore there are so many confusions and variations of maximum 2 times in loading capacity are come out. In this study, specifications of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio and sufficiency ratio of design load were analyzed. It can be known that the loading capacity specification of bi-directional pile load test must be defined as 1-directional test load that is established as more than 2 times of design load.

  • PDF

초고용량 양방향 말뚝재하시험(BDH PLT) 수행사례 분석 (A Case Study of High Capacity Bi-Directional High Pressure Pile Load Test)

  • 김상일;이민희;정성민;정은택;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1156-1163
    • /
    • 2010
  • The bi-directional high pile load test(BDH PLT) does not have weaknesses found in the existing bi-directional low pile load test(BDL PLT); it has strong economics, is unbound by load capacity limit and secures quality stability of working piles. In this study, Verification the field found a very high capacity level of stability and reliability of the BDH PLT, as well as outstanding field applicability. Field verifications reaffirmed the advantage of the BDH PLT device, which was capable of loading 90 MN capacities as maximum. It was also found to be durable enough to load high capacity with ease.

  • PDF

수산화철계 흡착제의 황화수소 흡착 특성 (Adsorption Characteristics of Hydrogen Sulfide on Iron Hydroxide-based Adsorbent)

  • 류승형;서영주;박준우;김신동;박성순
    • 한국폐기물자원순환학회지
    • /
    • 제34권5호
    • /
    • pp.468-473
    • /
    • 2017
  • This study was carried out to examine the characteristics of hydrogen sulfide adsorption using an iron hydroxide-based adsorbent. The prepared adsorbent was discussed with regard to its adsorption capacity and analyzed via surface analysis methods to illustrate the physical characteristics of hydrogen sulfide adsorption. As the drying temperature increased, the adsorption capacity of the adsorbent decreased from 29.15wt% to 22.73wt%. The adsorption capacity was decreased as the space velocity increased and showed an adsorption capacity of about 3.65 at $3,157.6h^{-1}$. The effect of sulfur dioxide was to decrease the adsorption capacity from 29.15wt% to 27.94wt%. The adsorbent exhibited the amorphous type in its physical appearance based on XRD and EDS analysis.

원심모형실험을 이용한 모래지반에 관입된 계류선 거동 평가 (Evaluation of Behaviors on Mooring Line Embedded in Sand Using Centrifuge Test)

  • 이훈용;김수린;김재현;김동수;추연욱;권오순
    • 한국해양공학회지
    • /
    • 제28권1호
    • /
    • pp.47-54
    • /
    • 2014
  • When an anchor penetrates and is installed under a seabed, a portion of the mooring line connected to the anchor is also embedded under the seabed. This embedded mooring line affects the capacity of the anchor in two ways. First, the frictional resistance that occurs between the mooring line and the seabed reduces the pulling force acting on the anchor. Second, the embedded part of the mooring line forms a reverse catenary shape due to the bearing resistance of the soil, so that an inclined pulling force is applied to the anchor. To evaluate the mooring line's effect on the capacity of an anchor in sand, centrifuge model tests were performed using two relative sand densities of 76% and 51% while changing the anchor depths. The test results showed that the load is reduced much more in deep and dense sand, and the inclination angle of the load is lower in shallow and loose sand.

농업용 호소의 수질개선을 위한 오염총량관리제의 적용에 관한 연구 (A Study on the Application of Total Pollution Load Management System for Water Quality Improvement in Agriculture Reservoir)

  • 오대민;이영신
    • 한국환경보건학회지
    • /
    • 제35권5호
    • /
    • pp.365-375
    • /
    • 2009
  • Agriculture reservoirs need a systematic approach that can control water purity and water improvement. The area under study, Bunam Lake exceeds the agricultural water standard level due to contamination from the upper stream. When the Taean Enterprise City was planned, the water quality improvement plan was applied to minimize the environmental change. However, in order to continuously maintain the water quality in the Bunam Lake, it was essential to apply the Total Pollution Load Management System (TPLMs). In order to achieve the targeted water quality in the Bunam Lake, standard flow rates and targeted water quality levels were applied to obtain the loading capacity which is as follows : BOD 1,891.2 kg/d, T-N 1,945.7 kg/d, T-P 131.7 kg/d. Also, the regional development load was calculated as, BOD 1,083.6 kg/d, T-N 942.2 kg/d, T-P 61.8 kg/d, which is required to be deceased :- by BOD 378.4 kg/d, T-N 198.9 kg/d, T-P 31.6 kg/d in order to safely achieve the targeted water quality in the Bunam Lake.

페콘크리트의 중화 및 중금속 제거를 위한 재활용에 관한 연구 (I) (A Study on Recycle of Waste Concretes for Neutralization and Removal of Heavy Metals ( I ))

  • 김은호;김정권;성낙창
    • 한국환경과학회지
    • /
    • 제6권5호
    • /
    • pp.497-503
    • /
    • 1997
  • This study was performed to Investigate the utilization of waste concretes for neutralization and removal of heavy metals In plating wastewater, because waste concretes have been known to be very porous, to have high species surface area and to have alkaline minerals such as calcium. The results obtained from this research showed that waste concretes had a buffer capacity to neutralize an acidic alali system in plating wastewater. Generally, neutralization and removal rate of heavy metals were excellent in the increase of waste concrete amounts and a small size. Because a coefficient of correlation was high, it seemed that removal of heavy metals could be explained by Freundlich and Langmuir isotherms. If we reflected the adsorption capacity(k) and adsorption intensity(1/n) of Freundlich isotherm, we couldn't consider waste concretes as a good adsorbent. But, we could know that waste concretes were capable of removing a part of heavy metals. In point of building waste debris, if waste concretes substituted for a valuable adsorbent such as actuated carbon, they could look forward to an expected economical effect.

  • PDF

Styrene Degradation in a Polyurethane Biofilter Inoculated with Pseudomonas sp. IS-3

  • KIM JAISOO;RYU HEE WOOK;JUNG DONG JIN;LEE TAE HO;CHO KYUNG-SUK
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권6호
    • /
    • pp.1207-1213
    • /
    • 2005
  • In a search for bacteria capable of degrading styrene better than previously isolated strains, bacterium IS-3 was isolated from activated sludge and found to be most closely related to Pseudomonas sp. Styrene degradation by this strain was tested in liquid cultures and polyurethane-packed biofilters. In liquid cultures, the rate of styrene degradation by this bacterium increased from 24.93 to $76.53\;{\mu}mol\;g^{-1}\;DCW\;H^{-1}$ for an initial mass range from 8.7 to $34.8{\mu}mol$. The maximum styrene elimination capacity was 580-635 $g/m^{3}\cdot$h at a space velocity (SV) of 50-200/h. The critical elimination capacities guaranteeing $95\%$ removal of the input styrene were determined to be 635, 170, and 38 $g/m^{3}\cdot$h, respectively, at SVs of 50, 100, and 200/h. Kinetic analysis revealed that the maximum styrene elimination velocity ($V_{m}$) for this biofilter was 1,000 g/m$\cdot$h, and the saturation constant ($K_{m}$) was 454 ppmv. Together, these results suggest that a polyurethane biofilter containing Pseudomonas sp. IS-3 could have potential practical applications for the effective removal of styrene gas.

친환경 캠퍼스 평가 기준 도출에 관한 연구 (A Study on the Assesment Guideline for Environment-Friendly University Campuses)

  • 노미영;신지훈;임승빈
    • 한국환경복원기술학회지
    • /
    • 제11권4호
    • /
    • pp.103-118
    • /
    • 2008
  • University campuses, in Korea, experienced expansion during the 1970's and exceeded its capacity in the 1980's. On the other hand, universities needed to deal with increasing capacity and expansion of its facilities. This study is carried out in three steps : developing the factors of environmental friendly assessment, designing an assessment table based on specific categories, and applying the categories to the campus of Seoul National University. The assessment factors and assessment table were designed through a survey of experts in landscaping, architecture, and urban planning. The elements of major categories were classified as follows; 1) Management of land and accessibility, 2) Pollution and waste matter, 3) Energy, 4) Natural resources, 5) Operation, maintenance and management of environmental friendly campus. And, this study classified five major categories into twenty subcategories on the evaluation of the environmental friendly campus. The twenty subcategories include various fields such as architecture, landscape architecture, environment, urban design, and social sciences etc., profound studies at this line should make more precise assesment guidelines.

낙동강중류의 토지피복형태를 고려한 유역별 수질오염도 분석 (An Analysis on Water Pollution Degree by the Watershed considering Landcover Types in the Mid-Nakdong River)

  • 이우성;정성관;박경훈;유주한
    • 한국환경과학회지
    • /
    • 제15권4호
    • /
    • pp.349-357
    • /
    • 2006
  • The purpose of this study is to evaluate the water pollution degree in the Mid-Nakdong River watershed regarding to landcover types using GIS method. As a result of landcover classification, rate of urban appeared highly on Daegu Metropolitan city. Also, rate of agriculture showed highly in the riparian zones of the Nakdong and Guemho River and rate of forest appeared highly in the borders of the study area. To identify the groups of watershed with similar landcover patterns using the Cluster Analysis. According to the cluster analysis, the fifty sub-watersheds were grouped in three clusters, 'Urban watershed', 'Agriculture watershed', 'Forest watershed'. The proportion of urban area in each cluster had a positive correlation with water pollution degree. Otherwise, the proportion of agriculture in the Agriculture watershed had a high positive correlation with water pollution degree. Therefore, it is necessary to estimate environmental capacity of water duality considering ecological and environmental characteristics of watershed ecosystem and expand water duality monitoring systems to small stream.