• Title/Summary/Keyword: Environmental capacity

Search Result 3,944, Processing Time 0.033 seconds

Numerical parametric analysis on the ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips

  • Zhang, Yingying;Song, Xiaoguang;Zhang, Qilin
    • Structural Engineering and Mechanics
    • /
    • v.63 no.2
    • /
    • pp.195-206
    • /
    • 2017
  • This paper presents the parametric numerical analysis on the ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips. The effects of several factors on failure modes and ultimate bearing capacity of the purlins are studied, including setup of anti-sag bar, purlin type, sheet thickness and connection type et al. A simplified design formula is proposed for predicting the ultimate bearing capacity of purlins. Results show that setting the anti-sag bars can improve the ultimate bearing capacity and change the failure modes of C purlins significantly. The failure modes and ultimate bearing capacity of C purlins are significantly different from those of Z purlins, in the purlin-sheet roof connected by standing seam clips. Setting the anti-sag bars near the lower flange is more favorable for increasing the ultimate bearing capacity of purlins. The ultimate bearing capacity of C purlins increases slightly with sheet thickness increasing from 0.6 mm to 0.8 mm. The ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips is always higher than those by self-drilling screws. The predictions of the proposed design formulas are relatively in good agreement with those of EN 1993-1-3: 2006, compared with GB 50018-2002.

Assesment on the Characteristics of Foundation Bearing Capacity in Reinforced Soil Wall Structure of Large Scale (대규모 보강토옹벽 구조물에서의 기초지반 지지력특성 평가)

  • Han, Jung-Geun;Yoo, Seung-Kyung;Cho, Sam-Deuk;Lee, Kyang-Woo;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • The reinforced soil retaining wall structures of serious types with environmental are widely expanding more and more in Korea, which divided conventional type's reinforced soil retaining wall on segmental retaining wall. The causes of most crack occurred at block in reinforced soil retaining wall structure caused by the differential settlement of foundation. It is difference of settlement for significant factor that with overall slope stability. In this study, design assessment of foundation bearing capacity related to differential settlement of foundation ground was considered. And, also, through case study, the countermeasure methods and its application were suggested that the bearing capacity of foundation had to stabilize. The foundation ground in charge of bearing capacity should be affected by the resisting force of sliding, because the foundation parts of reinforced soil retaining wall were belongs to potential slope sliding area in overall stabilizing including retaining wall structures. Therefore, the analyzing or the designing of bearing capacity for foundation should be considered control capacity on the overall slope sliding.

  • PDF

Changes in Properties of Tropical Kapok Fibers by the Pretreatments (열대산 케이폭 섬유의 전처리에 따른 특성 변화)

  • Shin, Soo-Jeong;Jung, Woong-Ki;Sung, Yong Joo;Lee, Joon-Woo;Kim, Se-Bin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • The effets of the pretreatments of tropical kapok fibers were evaluated in this study in terms of water sorption capacity and oil sorption capacity. The alkali treatments with NaOH resulted in the reduction of lignin, oil and hemicellulose, which were detected with FT-IR spectrum. The reduction of the lyphophilic components such as fat on kapok fiber by the ozone treatments were also measured with FT-IR spectrum. The oil sorption capacity of kapok fiber was decreased by the alkali treatments and the ozone treatments, while the water sorption capacity was increased. The liquid sorption capacity were greatly affected by the mechanical cutting of kapok fiber which exposed the big lumen of kapok fiber. The hydrophilic property of kapok fiber could be controlled by the pretreatments, which would increase the applicability of kapok fiber for preparation of various functional paper products.

Bearing Capacity Characteristics of Stone Column by Numerical Analysis (수치해석에 의한 쇄석기둥의 지지력 특성)

  • Chun, Byung-Sik;Kim, Baek-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.1
    • /
    • pp.75-84
    • /
    • 2004
  • Stone column is one of the soft ground improvement method, which can enhance ground conditions such as the settlement reduction and the increasement of bearing capacity with applying the crushed stone instead of sand. In recent, general construction material, sand is in short of supply. Therefore, the bearing capacity improvement by the stone column is considered as the alternative method needed in many cases so the bearing capacity estimation is considered as important point. Nevertheless, adequate estimation methods to predict bearing capacity of stone column considering stone column and improvement effect of ground is not yet prepared. For the analysis of above mentioned points, the behavior of stone column were simulated as numerically on various property cases of crushed stone and surrounded ground. Through the numerical analysis of simulation results, the formula for the bearing capacity estimation of stone column was suggested. This formula was verified by comparing the prediction result of in situ test.

  • PDF

Experimental Study on Capacity Variation of Paving Materials with TiO2 in Wet Condition (광촉매 이산화티타늄(TiO2)을 혼합한 도로 포장재의 습윤 조건에서의 성능 변화에 관한 실험적 연구)

  • Seo, Dawa;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.5
    • /
    • pp.49-55
    • /
    • 2016
  • This study aims to present the practical Nitrogen monoxide (NO) removal capacity of cement mortar with Titanium dioxide ($TiO_2$) which is one of the paving materials by considering the environment of pavement in urban areas. NO removal capacity test under designated conditions of humidity of inflow gas and the test with variation of the degree of saturation of specimen were conducted. In the test for humidity, dry specimen is subject to the test and NO removal ratio was observed. Humidity-NO removal ratio curve is a log normal distribution in shape, and the maximum NO removal ratio appears at specific humidity. NO removal capacity test relying on the degree of saturation was carried out with wet specimen to reflect the unsaturated pavement by rainfall and domestic sewage. Wet specimen presents less NO removal capacity than dry specimen and the recovering evolution of NO removal capacity follows evaporation. Moreover, $TiO_2$ under the specific depth of specimen hardly contributes to NO removal capacity.

Load Carrying Capacity and Failure Mechanism of Geogrid Reinforced Stone Columns : Reduced-Scale Model Tests (지오그리드 보강 Stone Column의 파괴메카니즘 및 지지력 특성 - 축소모형실험을 통한 고찰)

  • Lee, Dae-Young;Song, Ah-Ran;Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.121-129
    • /
    • 2006
  • Stone column is one of the ground improvement systems which is being used for accelerating consolidation and increasing bearing capacity for settlement sensitive structures like load embankments, bridge abutments, oil storage tanks etc. The effects of this method are enhancement of ground bearing capacity, reduction of settlement, prevention of liquefaction and prevention of lateral ground movement. Recently, geosynthetic reinforced (encased) stone column approach has been developed to improve its load carrying capacity through increasing confinement effect. Although such a concept has successfully been applied in practice, fundamentals of the method have not been fully explored. This paper presents the results of an investigation on the bearing capacity and failure mechanism of geogrid-encased stone column by model tests. The results of the analyses indicated improved bearing capacity of the geogrid reinforced stone column method over the conventional strone column method with no encasing.

Uplift Capacity of a Plate Anchor Considering Suction Effects

  • Seo, Young-Kyo;Kim, Tae-Hyung
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2008
  • Anchors have been commonly used to as foundation systems of the structures that require the uplift resistance. Recently anchors have been used in ocean sediment for mooring systems to stabilizeoffshore structures. In the saturated clayey soil however suction developed between the soil and andchor and affects the uplift capacity of anchor. To estimate the uplift capacity of the andchor accurately, the failure mechanisms of the andchor by the uplift force should also be correctly assumed. The uplift capacity is usually expressed in terms of breakout factors with respect to embedment ratio. In this paper, a two-dimensional plane strain numerical investigation into the vertical uplift capacity of a plate andchor in a clayey soil is described. The breakout factor against their corresponding values of embedment ratio was calculated and plotted along a single curve. The modes of failure mechanism at shallow and deep andchors are also presented.

The Relationship between the Load Carrying Capacity and Transformed Impact Factor of Highway Bridge (교량의 공용내하력과 환산충격계수 관계 연구)

  • Chai, Won-Kyu;Lee, Myeong-Gu
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.138-143
    • /
    • 2012
  • In this thesis, the relationship between the load carrying capacity and the transformed impact factor of the highway bridges were studied. The bridges are classified according to superstructures type. The result of the comparison between the load carrying capacity and the transformed impact factor, if the load capacity ratio of 0.57, the transformed impact factor was less in order of RC T-beam bridge, RC slab bridge, PC beam bridge, I-beam bridge. By the regression analysis on these results, the empirical formulae to predict the the load carrying capacity of bridge were suggested.

Flexural Capacity of RC Composited H-Pile (철근콘크리트 합성 H-Pile의 휨성능)

  • Kim, Min-June;Shin, Geun-Ock;Jeong, Je-Pyong
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.563-570
    • /
    • 2016
  • The composited structural member in which two or more materials having different stress-strain relationships (steel & concrete) has increased greatly in recent years. This paper presents the experimental results of flexural capacity of the composited H-Pile subjected to bending moment. Eight composited beams were tested under direct loading condition using the frame tester. Based on the experimental results it is noted that flexural capacity of composited H-Pile increased about 20~30% and ductility ratio significantly increased. Limit state analysis of the specimens was conducted and the result shows that flexural strength by limit state analysis is conservative.