수출형 KT-1 훈련기 고/저온 환경시험절차 적합화 연구 (A Study on the Tailoring of High / Low Temperature Test for KT-1 Trainer Export Version)

  • 김진석
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.78-86
    • /
    • 2020
  • The environmental tests are one of the key branches of the reliability tests. The purpose of the high/low environmental test of KT-1 Export Version Trainer is not only based on meeting the compliance of the reliability, customer satisfaction, but also for the expansion of its export. Amongst many existing environmental tests, the high and low temperature tests are considered as the two most important tests. The tests are considered and tailored to the high and low temperature methods of MIL-STD-810H. This paper proposes the tailoring processes and the results of High/Low temperature conditions, test procedures, and test profiles for the aircraft. Additionally, this paper is described by considering the view of MIL-STD-810H.

MIL-STD-810과 IEC Pub. 60068 기후적 환경시험 규격의 비교 (Comparison of Climatic Environmental Test Standards of MIL-STD-810 and IEC Pub. 60068)

  • 김혁진;김명수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권2호
    • /
    • pp.81-91
    • /
    • 2009
  • This paper presents the comparison of climatic environmental tests of IEC Pub. 60068 and MIL-STD-810. Cold, dry heat, change of temperature, and heat-humidity cyclic tests are compared in terms of the types of tests and test severities. This study shows the difference between the standards, which will provide the useful information to the industries and be helpful in applying the standards.

  • PDF

간극수의 pH가 점성토의 강도와 압밀특성에 미치는 영향 (The Characteristics of Strength and Consolidation of Clayey Soil Dependent on pH of Soil Pore Water)

  • 이호진;김병일;박상규;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1047-1054
    • /
    • 2005
  • The purpose of this study is the understanding to changes in the characteristic of soil structure and classification, atterberg limits, undrained shear strength and consolidation of clayey soil dependent on pH of soil pore water. A series of tests including consistency tests, uniaxial compressive tests, vane tests and oedometer tests are performed on. The test results indicated that pH changes in the soil pH resulted in changes in the soil structure and classification, stress-strain behavior. Specially, when pH is conditioned to 7, liquid limit, undrained shear strength and preconsolidation pressure are the largest.

  • PDF

함정운용 유도탄 전기체(全機體)의 진동충격 환경시험 (A Vibration and Shock Environmental Tests for the Missile Installed in the Naval Vessels)

  • 권병현;권종화;안성우;이호준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.809-812
    • /
    • 2005
  • This paper explains environmental tests of vessel-launched missiles, verifying if a fully assembled missile performs properly from disturbance on delivery by vehicles or naval vessels. We also have operated vibration tests by ground and naval transportation as well as shock tests by naval transportation before firing. The environmental tests have adopted Military Standard Specification and confirmed missile's reliability by performance tests, followed by missile's development. However, this significant testing which have meaning was dong by the missile's body and not with parts.

  • PDF

Impact of Nuclear Tests on Deforestation in North Korea using Google Earth-Based Spatial Images

  • Ki, Junghoon;Sung, Minki;Choi, Choongik
    • 인간식물환경학회지
    • /
    • 제22권6호
    • /
    • pp.563-573
    • /
    • 2019
  • The North Korean government conducted its first nuclear test in 2006 and more recently the sixth nuclear test on September 3, 2017. In order to identify how North Korea's nuclear tests have affected the environment, a scientific approach is required. Although North Korea's nuclear tests and their environmental destruction are not a severe threat to the environment of the Korean Peninsula at this time, identifying environmental damage and taking countermeasures in advance are essential to minimize their potential threats to the environments. The purpose of this study is to study the environmental impact of North Korea's nuclear tests using Google Earth image analysis. As a method of the study, we compare Google Earth images taken before and after each nuclear test was conducted in North Korea. To overcome limitations of the suggested comparison method, we cross-checked our results with those of previous scientific research. After the 1st-3rd nuclear tests, green spaces were found to be considerably reduced. In particular, when comparing the Google Earth images before and after the second nuclear test, some ground subsidences were observed. Such subsidences can cause tunnels on the mountainsides and cracks in rocks around the mountains, leading to the release of radioactive materials and contaminating groundwater. Besides, after the 4th-6th nuclear tests, decay and deforestation were observed not in the nuclear test sites, but in their surrounding areas. Especially after the 5th and 6th nuclear tests, the topography and the forests of the surrounding areas were severely damaged. In relation to North Korea's nuclear tests and their impact on the natural environment, we need to prepare various policy measures to reduce North Korea's environmental pollution and natural environment destruction. Those policy measures include the establishment of various cooperative governance between the Korean government, the private sector, the academia, NGOs, and international organizations.

힘제한 방법을 이용한 소형 위성의 진동시험 (Force Limited Vibration Tests of Micro-Satellites)

  • 김영기;김홍배;김경운;우성현;김성훈;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.446-451
    • /
    • 2004
  • Over testing problems of satellites and theirs components have been issued due to their effects on satellite development cost and schedule. Force limited vibration tests were introduced as solution of the problems in 1980s. Over testing phenomena occurs due to the lack of similarity on interface impedance. Force limited vibration tests control interface force to simulate actual interface impedance. In this research, force limited vibration tests are applied on two satellites environmental tests. Force limits are calculated by using TDFS method and Semi-Empirical method. Four force sensors are employed to control interface force. The tests prove that force limited control reduced maximum interface acceleration in order of 3.

  • PDF

자동차 전장품의 환경시험규격에 관한 연구 (Environmental Test Specifications for Automotive Electrical Units)

  • 김용수
    • 품질경영학회지
    • /
    • 제46권2호
    • /
    • pp.311-326
    • /
    • 2018
  • Purpose: Using international specifications, this study classified international standards and automobile manufacturers' test items based on the kind of test used and determined the test order for ISO 16750. Methods: The effects of international standards' environmental factors were examined, based on the major impacts of the product and the results of product failure. Automobile manufacturers' test items were compared with the test item in the ISO 16750. A generic algorithm was then used to determine the test sequence for ISO 16750. Results: International standards and automobile manufacturers' common test items were classified. The test sequence of ISO 16750 was determined for five cases. Conclusion: Although mechanical and environmental tests share many common features, there are differences in the details of the tests. There is a common sequence of tests, but weights are allocated tests differently.

열적-알칼리성 전처리 유무에 따른 폴리하이드록시부티레이트의 고온 혐기성 소화 영향 연구 (Thermophilic Anaerobic Digestion of Polyhydroxybutyrate with and without Thermo-alkaline Pretreatment)

  • 이지현;이준엽
    • 한국환경과학회지
    • /
    • 제33권2호
    • /
    • pp.121-129
    • /
    • 2024
  • The study investigated the effect of thermo-alkaline pretreatment on the solubilization of polyhydroxybutyrate (PHB) and its potential to enhance of thermophilic anaerobic digestion, focusing on biochemical methane potential (BMP) and methane production rate, using two different particle sizes of PHB (1500 ㎛ and 400 ㎛). Thermo-alkaline pretreatment tests were conducted at 90 ℃ for 24 hours with varying NaOH dosages from 0-80% (w/w). BMP tests with untreated PHB exhibited methane production ranging from 150.4~225.4 mL CH4/g COD and 21.5~24.2 mL CH4/g VSS/d, indicating higher methane production for smaller particle sizes of PHB, 400 ㎛. Thermo-alkaline pretreatment tests achieved a 95.3% PHB solubilization efficiency when 400 ㎛ PHB particles were treated with 80% NaOH dosage at 90 ℃ for 24 hours. BMP tests with pretreated PHB showed substantial improvement in thermophilic anaerobic digestion, with an increase of up to 112% in BMP and up to 168% in methane production rate. The results suggest that a combined pretreatment process, including physical (400 ㎛ PHB particles) and thermo-alkaline (90 ℃, 40-80% NaOH dosage, and 24 hours reaction time), is required for high-rate thermophilic anaerobic digestion of PHB with enhanced methane production.

Nickel removal from low permeable kaolin soil under unenhanced and EDTA-enhanced electrokinetic process

  • Asadollahfardi, Gholamreza;Nasrollahi, Mostafa;Rezaee, Milad;Darban, Ahmad Khodadadi
    • Advances in environmental research
    • /
    • 제6권2호
    • /
    • pp.147-158
    • /
    • 2017
  • This paper represents a set of experimental tests on remediation of nickel-contaminated kaolin by Electrokinetic method. For this purpose, we conducted unenhanced and EDTA-enhanced Electrokinetic tests in one, three, and five days of treatment. In unenhanced tests, we used deionized water as an electrolyte in the anode and the cathode compartments. In the EDTA-enhance tests, we used ethylenediaaminetetra acetic acid 0.1 Molar in the cathode and sodium hydroxide 0.1 Molar in the anode. The average nickel removal for unenhanced tests after three and five days of treatment was 19 and 23 percent, respectively. High buffer capacity of the soil is responsible for low removal efficiency in the unenhanced tests, which maintained pH close to the initial amount that restrained nickel as an adsorbed or precipitated forms. The average nickel removal for EDTA-unenhanced tests after three and five days of treatment was 22 and 12 percent, respectively. Lower ionic mobility of EDTA-Ni complex in comparison with $Ni^{+2}$, which is the main transportation mechanism for this complex, could be responsible for less removal efficiency in EDTA-enhanced test.

퇴직한 납 근로자들의 체내 납 부담 노출지표가 신경행동학적 기능에 미치는 영향 (The effect of body lead burden on neurobehavioral function in retired lead workers)

  • 김남수;김진호;이병국
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.156-167
    • /
    • 2010
  • To evaluate the effect of lead biomarkers including bone lead on neurobehavioral test in retired lead workers, 131 retired lead workers without any occupational exposure to organic solvent, mercury and arsenic were agreed to participate this study. For the control subjects 56 non-occupationally lead exposed subjects were recruited from same area of retired lead workers with consideration of demographic characteristics. The mean levels of blood and bone lead of retired lead workers were significantly higher than control group and there were significant correlation among other lead biomarkers. Compared with controls without occupational lead exposure, lead exposured subjects had worse performance on 10 tests out of 12 neurobehavioral tests, but only two tests(Purdue pegboard nondominant and both hand) showed statistical significance of differences. In multiple linear regression analysis of neurobehavioral tests with lead biomarkers and demographic and lifestyle variables, age was associated negatively with 11 neurobehavioral tests, whereas log-transformed ZPP was associated with Purdue pegboard(both hand) and Santa Ana manual dexterity(non-dominant hand). On the other hand, tibia lead was associated Pursuit aiming test(correct) and Purdue pegboard(dominant hand) and calcaneal lead was associated with Purdue pegboard(dominant hand). This study confirmed that among all relevant variables age was most significantly associated with the poor performance of neurobehavioral tests. The blood lead did not have any significant association with neurobehavioral tests, but tibia and calcaneal bone lead and blood ZPP showed significant association with a few tests even after more than mean 9 years from their retirements.