• Title/Summary/Keyword: Environmental Factor

Search Result 6,484, Processing Time 0.034 seconds

A Study on the Correlationship among QSAR Parameters and Toxicity Data of Amine- and Nitrocompounds (아민 및 니트로화합물에 대한 QSAR의 물리화학적 매개변수 및 독성과의 상관관계)

  • 김재현;김애경
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.1_2
    • /
    • pp.45-54
    • /
    • 1999
  • Quantitative strucrure-activity relationships between the toxicity (LD$\_$50/) and molecular properties of amine and nitro compounds were tested. The all 19 compounds showed low correlations below 0.500 to their LD$\_$50/ values. When amine or nitro compounds were taken separately, the correlation between the calculated chemphysico parameters and LD$\_$50/ were also poor (r$^2$=0.4911, 3967 repectively). The overall relationships among the QSAR parameters were investigated. Molecular weight shows a high correlation with total surface area (r$^2$=0.9287); 0.9090 for zero-order connectivity and second-order connectivity : 0.8784 for bioconcentration factor and second-order connectivity. When amine compounds were taken to perform the statistical treatment, the relationships between parameters were as follows: 0.8436 for volume-negentropy; 0.8925 for volume-bioconcentration factor; 0.9929 for zero-order connectivity-Kow; zero-order connectivity-bioconcentration factor; 0.9141 for zero-order connectivity-solubility; 0.9718 for solubility-bioconcentration factor; 0.9894 for solubility-bioconcentration factor and 0.9319 for Kow-bioconcentration factor. On the other hand, nitro compounds showed different relationships as follows: 0.8952 for volume-I/O character; 0.9520 for volume-total surface area: 0.9351 for volume-molecular weight; 0.9351 for volume-MW; 0.9961 for Kow-Koc; 0.8455 for Kow-bioconcentration factor; 0.8879 for Koc-bioconcentration factor; 0.9987 for MW-total surface area respectively.

  • PDF

Water Quality Characteristics of the Major Tributaries in Yeongsan and Sumjin River Basin using Statistical Analysis (통계분석을 이용한 영산강·섬진강수계 주요 유입지천의 수질 특성)

  • Park, Jinhwan;Jung, Jaewoon;Kim, Daeyoung;Kim, Kapsoon;Han, Sungwook;Kim, Hyunook;Lim, Byungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.2
    • /
    • pp.171-181
    • /
    • 2013
  • In this study, we report the water quality characteristics of pollutants for 4 major tributaries in the Yeongsan and Sumjin river basins using statistical analysis, such as regression equation and factor analysis. The flow rate and water qualtiy data collected from 4 sampling sites(Hwangryoung A, Jiseok A, Chooryeong A, Osu A) in the Yeonsan and Sumjin river basin during the past 3 years were analyzed for 11 parameters(flow rate, dissolved oxgen, pH, water temperature, electric conductivity, biochemical oxygen demand, chemical oxygen deman, total organic carbon, total nitorgen, total phosphorus, suspended solid). The results showed that the concentrations of BOD, COD, TOC, T-N, T-P in Hwangryoung A(HW) and Jiseok A(JS) of the Yeongsan river basin were decreased as the flow rate was increased. This means that rather than nonpoint soources, point sources affect water quality. In the cases of Chooryeong A(CR) and Osu A(OS) in the Sumjin river basin, howerever, nonpoint sources than point sources are an important factor that affects the water quality. Also, the factor analysis technique was employed to analyze principal component influencing on water quality. The results revealed that the first principal component in HW was correlated with EC, DO, T-N, water temperature. This "nitrogen influx according to seasonal pattern" factor may be interpreted. In JS, the first principal component was correlated with BOD, COD, TOC and is likely to represent "organic matter" processes. In CR and OS, BOD, COD, TOC, SS and T-P were significantly correlated and is considered as representing "Organic matter and adsorption of phosphorus on sediments influx". This study is expected to contribute to the effective pollution control/management of the surfac waters in the study sites.

The Estimation of Emission Factor of N2O and CH4 by Measurement from Stacks in the Waste Incinerators and Cement Production Plants

  • Choi, Sang-Min;Im, Jong-Kwon;Hong, Ji-Hyoung;Lee, Sue-Been;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.3
    • /
    • pp.217-226
    • /
    • 2007
  • The purpose of this study is to estimate the emission factor of $non-CO_2$ global warming gases such as $N_2O$ and $CH_4$ by measuring concentrations from stacks of waste incinerators and cement production plants. Based on the established monitoring methods, $N_2O$ concentration measured from stacks in incinerator were between 0.62 and $40.60\;ppm_v$ (ave. $11.50\;ppm_v$). The concentration of $N_2O$ was dependent on the incinerator types. However, the concentrations of $CH_4$ gas were between 2.65 and $5.68\;ppm_v$ (ave. $4.22\;ppm_v$), and did not show the dependency on the incinerator types. In the cement production plant, the concentration ranges of $N_2O$ from the stack were from 6.90 to $10.80\;ppm_v$ (ave. $8.60\;ppm_v$), and $CH_4$ were between 1.80 and $2.20\;ppm_v$ (ave. $2.60\;ppm_v$). Using measured concentrations, the emission amounts of $N_2O$ and $CH_4$ from stacks per year were calculated. The results were is 4.2 ton $N_2O/yr$ in the incinerators, and 53.7 ton $N_2O/yr$ in the cement facilities. The big difference is from the flow rate of flue gas in the cement facilities compared to the incinerators. By the same reason, the $CH_4$ emission amounts in cement plant and incinerator was found to be 339 ton $CO_2/yr$ and 34.1 ton $CO_2/yr$, respectively. Finally, the emission factor of $N_2O$ in the incinerators were calculated using the measured concentration and the amount of incinerated wastes, and was $42.5\sim799.1\;g/ton$ in kiln and stoker type, $11.9\sim79.9\;g/ton$ in stoker type, 90.1 ton/g in rotary kiln type, 174.9 g/ton in fluidized bed type, and 63.8 g/ton in grate type, respectively. Also, the emission factors of $CH_4$ were found to 65.2-91.3 g/ton in kiln/stoker type, 73.9-122 g/ton in stoker type, 109.5 g/ton rotary kiln, and 26.1 g/ton in fluidized bed type. This result indicates that the emission factor in incinerators is strongly dependent on the incinerator types, and matched with result of IPCC (International Panel on Climate Change) guideline.

A Study on the Satisfaction and Stress Factors of Clinical Practice for Dental Hygiene Students (일부 치위생학과 학생들의 병원실습 만족도와 스트레스 요인에 관한 연구)

  • Yoo, Ja-Hea;Kim, Jung-Hee
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2016
  • The purpose of this study was investigate the relationship between the degree of satisfaction of the clinical practice and the stress factors for dental hygiene students. Dental hygiene students to 232 people from May 21, 2012 to June 22, 2012 and analyzed using by SPSS for Windows ver. 12.0 program. Regarding the stress factors, by the school system, all the factors, including the environmental factor, the role factor, the interpersonal relationships factor, the ideal and value factor, and the Brief Encounter Psychosocial Instrument (BEPSI) were higher in the 3-year system than in the 4-year system (p<0.01). Regarding the stress factors according to the degree of satisfaction regarding the practices, all the factors were high when unsatisfied. Among these, the environmental factor was the highest (p<0.001). According to the practice organization, the environmental factor was the highest among the university dental hospital. The interpersonal relationship factor and the ideal and value factor were the highest among the dental hospitals. The role factor and the BEPSI were the highest among the dental clinics (p<0.01). When the hospital atmosphere was bad, the environmental factor was the highest (p<0.001). As a result of analyzing the correlations between the stress factors of the hospital practices, there were the positive correlations among the environment, the roles, the interpersonal relationship, the ideals and values, and the BEPSI (p<0.01). The stress factor that showed the biggest influence on the BEPSI was interpersonal relationships. In the clinical practice, because of the unfamiliar environment and the insufficiency of the interpersonal relationships, the stress indices of the students can be higher than at ordinary times. I believe that, as such, a systematic management plan for the clinical practice for raising the ability of the students to cope with the stress by themselves must be prepared.

Recommendations of Environmental Reduction Factor of FRP Rebar for Durability Design of Concrete Structure (콘크리트 보강용 FRP 보강근의 내구성 설계를 위한 환경영향계수의 제안)

  • Park Chan-Gi;Won Jong-Pil;Kang Joo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.529-539
    • /
    • 2004
  • The corrosion of steel rebars has been the major cause of reinforced concrete deterioration. FRP(Fiber-reinforced polymer) rebar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. However, FRP rebar is prone to deteriorate due to other degradation mechanisms than those for steel. The high alkalinity of concrete, for instance, is a possible degradation source. Therefore, the USA, Japan, Canada, UK. etc are using environmental reduction factor. Although difference design guidelines were drawn in many, including USA, Japan, Canada, UK etc, recommendations and coefficients that could take into account the long-term behavior of FRP reinforcement were not well defined. This study focuses on recommendation of environmental reduction factor of FRP rebar. Environment reduction factor were decided using durability test result. FRP rebars were subjected to twelve type of exposure conditions including alkaline solution, acid solution, salt solution and deionized water etc. The water absorption behavior was observed by means of simple gravimetric measurements and durability properties were investigated by performing tensile, compressive and short beam tests. Based on the experimental result, environmental reduction factor of hybrid FRP rebar(A), and (C) and CFRP rebar was decided as 0.85. Also, hybrid FRP rebar(B) and GFRP rebar were decided as 0.7 for the environmental reduction factor

Estimation of Environmental Characteristics for Deep Ocean Water Development Site Using Ecological Model (생태모델을 이용한 해상형 해양심층수 사업해역의 환경 특성 평가)

  • Kim, Dong-Myung
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.919-927
    • /
    • 2011
  • A ecosystem model was applied for understanding of circulation process of state variables in marine ecosystem. A mass balance was conducted by calculating the physical process. The sensitivity analysis was conducted to know which coefficient is the most effective factor to the state variables in the model. The results of the mass balance indicate that the primary production was 58.6 ton C/day in the case of mass flux. DIN and DIP in nutrient ingestion of phytoplankton were each 7.9 ton N/day, 1.1 ton P/day. POC and DOC in mineralization of organic matter were each 10.8 ton C/day, 40.6 ton C/day. The results of sensitivity analysis showed that the maximum growth rate of phytoplankton was the most important factor for overall state variables. In the case of nutrients, Half saturation constant of DIN, and mineralization rate of DOM for COD were important factor.

The Media Influence on Consumers' Energy-Saving Technology Adoption in Korea: An Empirical Study

  • Koo, Chulmo;Chung, Namho
    • Asia pacific journal of information systems
    • /
    • v.26 no.1
    • /
    • pp.189-210
    • /
    • 2016
  • The current study attempts to expand our understanding of the determinants of energy-saving technology (EST) use by focusing on the individual aspects of environmental behaviors. This study integrates the hedonic, normative, and gain goals to explain the causal relationship between users and EST use. By adopting Goal-Framing Theory, this study proposed three individual goal frames in the environmental context: hedonic (perceived pleasurability), normative (social norms), and gain goals (legislative pressure and economic factor). Partial Least Square (PLS) was used to analyze the data from 104 respondents. Eight of the ten hypotheses were strongly supported. We found that social norms, perceived pleasurability, economic factor, and legislative pressure had positive and significant effects on attitude to EST use. Interestingly, we found that media influence did not have a severe effect on perceived pleasurability, and that the economic factor enforces mainly positive attitude to EST. Important theoretical and practical implications of these findings are discussed.

Measure the Productivity of Airports in Korea Considering Environment Factor : An Application of DEA (환경요소를 고려한 국내공항 생산성 측정 : DEA모형의 적용)

  • Jeon, Seung-Jin;Lee, Chul-Ung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.4
    • /
    • pp.350-357
    • /
    • 2011
  • In the recent, it is gradually important for airport to consider environmental aspects as sustainable development is emerged. ICAO, FAA and individual countries has tried to reduce airport noise and pollution. Thus, the effort is needed to incorporate environmental factor into productivity indicator of airport. Our paper use DEA method with the non-parametric directional output distance function(DDF) to assess productivity of 14 airports in Korea during 2008~2010. In addition to three inputs, two conventional outputs, two undesirable outputs have been considered : noise and air pollution. Results are compared from models that do not include undesirable outputs. Inclusion in the analysis of the undesirable effects of airport operations leads to greater and closer airport's efficiency scores.

Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor (기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석)

  • Lee, Won-Yeong;Shim, Kyu-Il;Han, Sang-Ok;Park, Gang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF