Effects of the Liquid Manure Circulation System on the Environmental Improvement of Swine Farm (액비순환시스템의 양돈농장 환경개선 효과)

  • Ha, Duck-Min;Kim, Doo-Hwan
    • Journal of Environmental Science International
    • /
    • v.28 no.1
    • /
    • pp.137-145
    • /
    • 2019
  • The purpose of this study was to evaluate the effect of implementing a Liquid Manure Circulation System (LMCS) on the environmental improvement of swine farms. Bacterial counts at different circulation phases of the LMCS were measured. Air in the swine facility and the liquid manure in each step of LMCS were sampled and gaseous composition detected in swine farms both with and without LMCS to compare the environmental conditions in either case. There were no differences in the total bacteria count at any circulation phase in the LMCS. Escherichia coli were detected at a very low abundance only at the outlet of the slurry pit ($1.5{\times}10^2CFU/m{\ell}$). Salmonella were not detected at any phase. The LMCS clearly affected the odor strength of the swine farm and improved the air quality in the swine facility. On-site odor strength - inside, at the exhaust, and at the border of the swine facility - were clearly lowered in farms applying LMCS. Furthermore, the levels of ammonia, hydrogen sulfide, and carbon dioxide were improved in swine facilities applying LMCS.

A Method of River Environmental Impact Assessment using LCA (LCA를 적용한 하천환경영향평가 방법)

  • Kim, Sung-Joon;Jin, Ming-Ji;Jeon, Yong-Tae;Shin, Seon-Mi;Choe, Yong-Seung;Won, Chan-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.93-104
    • /
    • 2012
  • In this research LCA methodology was adapted and analyzed in quantifying estimation of estuarine environment. The analysed objects of estuarine environment were construction methods, facility, and input material into water, and estuarine ecosystem. In this research the function of LCA of estuarine environment was river with the view of controling water, utilizing water, and hydrophilic function. According to the result of research, environmental damage indicator of facility was decreased 346 Pt from 453 Pt at pre-maintenance to 107 pt at post-maintenance. Among raw and subsidiary materials, remicon, stone-netting bag, and pebbles were showing heavy environmental load in the order. Evironmental impact of input material into water system was analyzed from 1,827 Pt environmental load before construction to 1,080 Pt of post-maintenance, and damage indicator was improved at 747 Pt. Water quality was improved from 1,827 Pt (before construction) to 1,080 Pt(after construction), and ecosystem was improved after maintenance. Environmental indicator in ecosystem was analyzed 427 Pt(before construction) to 348 Pt(after construction), and damage indicator of Sumnjingang riverine system was improved as much as 79 Pt. In the conclusion, estuarine environmental monitoring through LCA in the area of facility, input material into water and ecosystem showed that close-to-nature stream was 1,172 Pt better than artificial stream in environmental aspects.

Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas (장기모의를 통한 도시유역 비점오염원 처리장치 용량 산정)

  • Joo, Jingul;Yoo, Doguen;Kim, Joonghoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.841-847
    • /
    • 2011
  • In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall - runoff - build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas.

Improvement for Classification System of Building Use on Neighborhood Living Facility (근린생활시설 용도분류체계 개선방안 연구)

  • Lee, Sung-Ok;Hwang, Eun-Kyoung
    • Journal of architectural history
    • /
    • v.21 no.6
    • /
    • pp.53-62
    • /
    • 2012
  • The purpose of this study is to present improvement for classification system of current neighborhood living facility to correspond rapid social change and various industries after understanding its status and problem. In current Building Standard Law, various kinds of buildings are classified for their structure, purpose of use, and building types. The Neighborhood Living Facility is divided into First Neighborhood Living Facility and Second Neighborhood Living Facility with applying area standards, according to facilities of convenience degree for neighborhood inhabitants. This classification, however, has problem in an arbitrary decision and applying of buildings without any definition or standards to adopt. And, there are some mixed neighborhood public functional facilities and amusement business affecting public morals among the Neighborhood Living Facility, so hazard environmental problems are also existed. According to the improved program, the study presents a prompt adoption of new facilities according to various industry increase, with minimum public discontent over adopted area standards. This study suggests making a clear scope through reclassification of Neighborhood Living Facility within the scope of the law on current Neighborhood Living Facility and an improvement plan of introducing necessary definitions on purpose of facility.

Development of High Intensity Progressive Wave Tube (고에너지 음향환경시험 튜브 개발)

  • K.Kim, Young-Key;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Im, Jong-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.962-965
    • /
    • 2005
  • A high intensity progressive wave tube is installed at Korea Aerospace Research Institute (KARI) for acoustic environmental tests. The test facility has 700 mm x 800 mm cross-sectional area, and provides acoustic environment of 165 dB over the frequency range of $25Hz{\sim}10,000Hz$. The facility consists of a 6 m long acoustic wave tube, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of the facility and power generation systems are controlled to meet the requirement of the test. The shape and length of the tube has been designed by using the size of test objects and the wave propagation characteristics of the tube. The capacity of acoustic power generation systems is determined by the energy conversion of acoustic wave and the efficiency of acoustic modulators. Moreover, the paper introduces test run results of the tube. Overall of 163dB has been generated by using the test facility.

  • PDF

Life Cycle Assessment (LCA) for Claculation of the Greenhouse Gas Emission Amount of Facility House -With Cucumber, Tomato, Paprika- (전과정평가를 통한 시설작물의 온실가스배출량 산정연구 -오이, 토마토, 파프리카를 중심으로-)

  • Kim, Tae-Hoon;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.21 no.2
    • /
    • pp.189-205
    • /
    • 2013
  • Climate change is rapidly getting worse. In Korea, the average temperature has increased by $1.5^{\circ}C$ over the last 100 years. In terms of global warming, it causes regional climate change, extreme weather phenomena and change of cultivated area. moreover, Global Warming brings both direct and indirect damage to agricultural cultivation. Global warming was accelerated by the greenhouse gas emissions which is by industry. In addition, Greenhouse gas emissions are increasing. In agriculture Thus we need to figure out how to analyze and to reduce greenhouse gas emissions and its cause. This study assumes that it is the introduction of the bio-energy using compost to facility house and it analyzes that there is the difference between in the future in utilizing compost due to the introduction of bio-energy facility houses; Environmental effect and Environmental effect which are generally used. This research is a previous step for resource-circulating, farming, utilizing a variety of by-products of the agricultural sector as an environmental assessment studies for the future completion of resource-circulating agriculture.

Application and Maintenance Strategies for Eco-Friendly Facilities in Landscape Trees Nurseries

  • Young Sun Seok;O Man Kwon;Yun Eui Choi
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.2
    • /
    • pp.151-165
    • /
    • 2024
  • Recently, as the number of landscaping plant nurseries have increased, environmental problems such as topographical damage due to indiscriminate changes in land use, increased non-point pollution, and increased impervious areas are also occurring. In this study, we propose eco-friendly facilities and a detailed maintenance manual that can enhance the eco-friendliness and scenic beauty of landscaping plant nurseries that are increasingly located near cities. By exploring previous reports on eco-friendly facilities and related laws, we cataloged the types of eco-friendly facilities, and by referring to examples of eco-friendly facilities introduced in overseas cases and the environmental functions of agriculture, we cataloged the types of eco-friendly facilities suitable for introduction in plant nurseries. The selected facilities are rain gardens, tree boxes, vegetated filter beds, bio-retention, infiltration trench, infiltration tanks, permeable pavements, and sand filtration systems. The maintenance tasks of eco-friendly facilities were categorized and management plans were proposed, which is expected to be utilized as a basic data to prepare eco-friendly space planning and operation management plans when creating a landscape plant nurseries in the future.

Health Risk Assessment of Occupants in the Small-Scale Public Facilites for Aldehydes and VOCs (일부 미적용 다중이용시설의 실내 공기 중 알데히드류 및 휘발성유기화합물 노출로 인한 건강위해성 평가)

  • Yang, Ji-Yeon; Kim, Ho-Hyun;Shin, Dong-Chun;Kim, Yoon-Shin;Sohn, Jong-Ryeul;Lim, Jun-Hwan;Lim, Young-Wook
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.45-56
    • /
    • 2008
  • This study was to assess the lifetime cancer and non-cancer risk of exposure of worker and user at public facilities in Korea to volatile organic compounds (VOCs). We measured the concentrations of two aldehydes and five VOCs in indoor air at 424 public buildings that 8 kinds of public facilities (70 movie theaters, 86 offices, 86 restaurants, 70 academies, 22 auditoriums, 30 PC-rooms, 30 singing-rooms and 30 bars) all over the country. There were estimated the human exposure dose and risks with averages of the using-time and frequency for facility users and office workers, respectively. Carcinogens (formaldehyde, acetaldehyde, and benzene) were estimated the lifetime excess cancer risks (ECRs). non-carcinogens (toluene, ethylbenzene, xylene, and styrene) were estimated the hazard quotients (HQs). The average ECRs of formaldehyde and benzene for facility worker and user were $1{\times}10^{-3}{\sim}1{\times}10^{-4}\;and\;1{\times}10^{-4}{\sim}1{\times}10^{-5}$ level, respectively, in all facilities. HQs of four non-carcinogens did not exceed 1.0 for all subjects in all facilities. The estimated ECRs for restaurant and auditorium were the highest, and the PC-room and bar were the next higher facilities. Furthermore, people in a smoking facility had the highest cancer risk. Higher ECRs of formaldehyde and benzene were observed in indoor smoking facilities such as restaurant and auditorium. Higher HQs of toluene and xylene were observed at the restaurant and office building.

Analysis of Citizen's Attitude to the Incineration (소각장에 대한 시민의식 조사분석)

  • Kim, Joong-Kee;Park, Chang-Hee;Chung, Jae-Chun;Lee, Sung-Taik;Heo, Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.2
    • /
    • pp.87-95
    • /
    • 1996
  • A questionary survey was performed to invetigate the citizen's attitude concerning the waste incineration facility. People disliked most cremetorim followed by waste transfer station, chmical factory, waste incineration facility and sanitary landfill. Most people favored 1km minimum distance of incineration facilities from the residence. Most people think that we need most composting facilities in the future followed by sanitary landfill and incineration facilities. Majority of people was willing to accept the perfect incineration facilities near their residence. However, 37.6% answered no. Most people accepted complusory measures by the goverment in the location of incineration facilites. One incineration facility per one city or Gun was slightly favored than multy-city or Gun incineration facility. People think that perfect thchnology most important to overcome Nimby's.

  • PDF

Influence of Effluent from a Sludge Carbonization Facility on Wastewater Treatability (슬러지탄화공정수 연계처리가 하수처리효율에 미치는 영향)

  • Han, Joo Eun;Park, Soo-Hyung;Lee, Wontae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.57-64
    • /
    • 2019
  • We investigated influence of connected influent on the treatability of a wastewater treatment plant (WWTP), recently accepting effluent from a sludge carbonization facility. Based upon the pollutant loading rates (kg/d) of each connected influent, food waste leachate and livestock wastewater contributed to high BOD and COD loadings, while sludge carbonization facility effluent certainly contributed to T-N and $NH_3-N$ loadings. The nitrification rate in aerobic tank decreased to 55% with the carbonization facility effluent entering to the WWTP, while it was 89% with no carbonization facility effluent entering. The sludge carbonization facility effluent may need to be pretreated to reduce T-N and $NH_3-N$ loadings before entering to the WWTP for further treatment.