• Title/Summary/Keyword: Environmental Control

Search Result 10,302, Processing Time 0.043 seconds

Optimization of Wheat Harvest

  • Kim, S.H.;Kolaric, W.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • Optimization was considered from three perspectives : minimum grain loss, minimum damaged grain loss, and minimum power consumption. Factors affecting combine performance were classified as control, adjustable, and environmental. Control and adjustable factors were optimized by the parameter design developed by Taguchi. Environmental factors were used as input for optimization. Optimum range for control and adjustable factors are presented. Parameter design was adequate to obtain the optimum levels of control factors and optimum range of adjustable factors.

  • PDF

OPTIMIZATION OF WHEAT HARVEST

  • Kim, Sang-hun-;William-J.Kolaric;Kang, Whoa-Seug
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.714-726
    • /
    • 1993
  • Optimization was considered from three perspectives ; minimum grain loss, minimum damaged grain loss, and minimum power consumption. Factors affecting combine performance were classified as control , adjustable , and environmental. Control and adjustable factors were optimized by the parameter design developed by Tajuchi. Environmental factors were used as input for optimization Optimum range for control and adjustable factors are presented. Parameter design was adequate to obtain the optimum levels of control factors and optimum range of adjustable factors.

  • PDF

Control of Automated Greenhouse Based on a PC (PC 기반 자동화 시설 하우스 제어)

  • 김기환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.9
    • /
    • pp.644-649
    • /
    • 2004
  • To control a greenhouse is to control environmental parameters in greenhouse. Controlled environments may be as simple as saran-covered shade houses or as complex as growth chambers. Although greenhouses are probably the most common example of a controlled environment used in agricultural/horticultural production, the type of controlled environment or system that is needed depends upon the climate, time of year, crops being produced and the environmental parameters that must be controlled. In this contribution puts emphasis on construction of automatic-controlled greenhouse system by personal computer.

The Effect of the Environmental Nursing Intervention on ICU Delirium, Environmental Stress and Sleep in Patients Underwent Cardiac Surgical Procedures (환경적 간호중재가 개심술 환자의 중환자실섬망증, 환경적 스트레스 및 수면에 미치는 효과)

  • Jang, In Sil;Choi, Mi Hye
    • Journal of Korean Clinical Nursing Research
    • /
    • v.14 no.2
    • /
    • pp.127-138
    • /
    • 2008
  • Purpose: To examine the effects of the environmental nursing intervention using eye-shields and earplugs on the incidence of delirium, environmental stress and sleep among the patients with open-heart surgery in the post-cardiac ICU(intensive care units). Method: This study was a non-equivalent control group non-synchronized design. The subjects consisted of 93 patients who received ICU care after the cardiac surgery. Among those, 32 subjects was assigned in one experimental group with eye-shields, 31 in the other experimental group with earplugs, and 30 in the control group. ICU delirium was measured by CAM-ICU, environmental stress by ICUESS, and sleep by two sleep scales developed by Oh, et al. and Kim. The data were analyzed by the SPSS 13.0 program including frequency, percentage, t-test, $x^2$ test, ANOVA and ANCOVA. Results: There are no statistically significant differences in the incidence of delirium among three groups (p=.139). The ICU environmental stress scores from the subjects of two experimental groups demonstrated lower (F=6.731, p=.002) than the control group. Also, the degrees of sleep pattern (p=.000, p=.000) and sleep satisfaction (p=.000, p=.000) were greater than those of the control group. Conclusion: Although the environmental nursing intervention using eye-shields and earplugs did not demonstrate the effects in decreasing the incidence of ICU delirium, it has affirmative effects in decreasing environmental stress and improving the quality sleep among the patients with open-heart surgery while they stay in ICU. Further nursing implications are discussed.

  • PDF

Highly catalysis Zinc MOF-loaded nanogold coupled with aptamer to assay trace carbendazim by SERS

  • Jinling Shi;Jingjing Li;Aihui Liang;Zhiliang Jiang
    • Advances in nano research
    • /
    • v.14 no.4
    • /
    • pp.313-327
    • /
    • 2023
  • Zinc metal organic framework (MOFZn)-loaded goad nanoparticles (AuNPs) sol (Au@MOFZn), which was characterized by TEM, Mapping, FTIR, XRD, and molecular spectrum, was prepared conveniently by solvothermal method. The results indicated that Au@MOFZn had a very strong catalytic effect with the nanoreaction of AuNPs formation between sodium oxalate (SO) and HAuCl4. AuNPs in the new indicator reaction had a strong resonance Rayleigh scattering (RRS) signal at 370 nm. The indicator AuNPs generated by this reaction, which had the most intense surface enhanced Raman scattering (SERS) peak at 1621 cm -1. The new SERS/RRS indicator reaction in combination with specific aptamer (Apt) to fabricate a sensitive and selective Au@MOFZn catalytic amplification-aptamer SERS/RRS assay platform for carbendazim (CBZ), with SERS/RRS linear range of 0.025-0.5 ng/mL. The detection limit was 0.02 ng/mL. Similarly, this assay platform has been also utilized to detect oxytetracycline (OTC) and profenofos (PF).

A Study of Control Efficiency for Odorous Pollutants in Various Emission Control Units in the Ban-Wall Industrial Complex (공단지역의 대기배출시설을 대상으로 한 악취성분의 처리효율에 관한 연구 - 반월공단 지역을 중심으로)

  • Choi, Y.J.;Jeon, E.C.;Kim, K.H.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.110-124
    • /
    • 2007
  • In this study, the control efficiency of odorous compounds was measured from diverse control process units of 14 individual companies located within the Ban-Wall industrial complex of Ansan city, Korea (January to July 2005), To quantify the control efficiency levels of major odorous compounds, we collected odor samples from both the front and rear side of 17 control process units ($N=17{\times}2=34$). If the control efficiency is compared for each of 32 compounds between different process units, wet scrubber (WS) was found to be the most effective unit in terms of the sum of pollutants showing the positive control signals. Although the WS system shows generally a good control pattern for VOC, it is not the case for most index odorous pollutants; only 3 out of 12 index compounds were found to show positive control efficiencies. The results of the study also indicated that the control efficiency differ greatly between different industrial sectors and/or control process types. In the case of leather industry, carbonyl compounds were found to exhibit the highest control efficiency with its values varying from 19 to 90%. On the other hand, in the case of metal production sector, VOC recorded the maximum control efficiency with values varying from 18 to 79%. According to this study, most air pollution control facilities operated in most companies show fairly poor control efficiencies for most malodor compounds. Hence, to obtain best control efficiency of odorous pollutant emission, acquisition of better information on source characteristics and establishment of effective control technologies are highly demanding.

Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing (실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례)

  • Kim, Jaehoon;Shin, Jinsoo;Lee, Chulgu;Lee, Jungyoung;Lee, Youngsun;Yu, Soonju
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

Research on the Development Management Basin and Goal for 3th T.W.Q on the Boundary between Metropolitan Cities/Dos Specified in Nakdong River Basin (낙동강수계 3단계 광역시·도 경계지점 목표수질 설정을 위한 관리권역 및 관리목표 설정 방법 연구)

  • Hwang, Ha Sun;Park, Ji Hyung;Kim, Yong Seok;Rhew, Doug Hee;Choi, Yu Jin;Lee, Sung Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.569-575
    • /
    • 2015
  • The current Total Pollution Load Control (TPLC) sets the Target Water Quality (TWQ) by utilizing the delivery ratio, unit loads, and water quality modeling, it also allocates the watershed's permitted discharge load. Currently, common target pollutants of every unit watershed in TPLC are BOD and T-P. This study has reviewed the 1th and 2th of TWQ setting process for the Nakdong River 3th TWQ setting in Total Pollution Load Control (TPLC). As a result of review, 1th and 2th were divided into one management basin (mulgeum) for setting management goals. However, 3th was divided into six management basins (mulgeum, gnagjeong, geumho river, nam river, miryang river, end of nakdong river). The principle of management goal setting were to achieve the objective criteria of Medium Areas for the linkage of the water environment management policy. And Anti-Degredation (principle of preventing deterioration) were applied to the 3th TWQ. Also, additional indicators were considered in accordance with the reduction scenarios for the final management goals.

Internet-Based Remote Control of the Intelligent Robot (지능형 로봇의 인터넷 기반 원격 제어)

  • Yu, Young-Sun;Kim, Jong-Sun;Kim, Hyong-Suk;Joo, Young-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.3
    • /
    • pp.242-248
    • /
    • 2007
  • In this paper, we implement the internet-based remote control system for intelligent robot. For remote control of the robot, it uses the socket communication of the TCP/IP. It consists of the user interface and the robot control interface. Robot control interface transmits the navigation and environmental informations of the robot into the user interface. In order to transmit the large environmental images, a JPEG compression algorithm is used. User interface displays the navigation status of the robot and transmits the navigation order into the robot control interface. Also, we propose the design method of the fuzzy controller using navigation data acquired by expert's knowledge or experience. To do this, we use virus-evolutionary genetic algorithm(VEGA). Finally, we have shown the proposed system can be operated through the real world experimentations.