• 제목/요약/키워드: Environment efficiency evaluation

검색결과 751건 처리시간 0.027초

Development of Evaluation Metrics for Pedestrian Flow Optimization in a Complex Service Environment Based on Behavior Observation Method

  • Bahn, Sang-Woo;Lee, Chai-Woo;Kwon, Sang-Hyun;Yun, Myung-Hwan
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.647-654
    • /
    • 2010
  • In a service environment, the spatial layout is an important factor that has a great impact on customers' behavioral characteristics including wayfinding and purchasing. Previous studies have shown a gap between marketing, focusing solely on profitability and satisfaction, and architecture, looking only into efficiency of pedestrian flow. To balance such disparity, this study suggests an integrated approach for assessing behavioral patterns in complex service environments. With the objective that complex service environments should aim to increase its profitability and efficiency while guaranteeing customer satisfaction, quantitative metrics was developed for evaluation. The metrics was defined to use data from behavior observation including path tracking, population counting, and gaze analysis, while previous studies have relied on abstract survey methods that were prone to sampling errors and loss of data. For validation of the metrics in a real world setting, a case study was conducted at 4 train stations in Korea. In the case study, experiments were conducted to gather the required data in all 4 train stations, while their physical layouts were also analyzed. With the results from the case study, comparative evaluation of the 4 train stations in terms of behavioral efficiency was possible, together with a discussion on the effect of their physical settings.

공동주택 주동 배치유형에 따른 주거환경성능 평가에 관한 연구 - 일조 및 조망환경성능 평가를 중심으로 - (A Study on the evaluation of the Residential Environment Efficiency by Arrangement of Multi-Family Residential Buildings - focused on the evaluation of daylight and view environment -)

  • 최두성;도진석
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.57-64
    • /
    • 2009
  • To make a prediction for a change of residential environment caused by the building code in Seoul which includes loosening the distance between multi-residential buildings, proposals of the four main building arrangements by analyzing examples were selected and then, amount of daylight and view efficiency were analyzed and presented through computer simulation for the proposals. In the result of the analysis, there was a difference among the arrangements but, when the distance between buildings was applied 0.8H as the least, residential environment like daylight and view efficiency per unit significantly decreased in quality. Particularly, for the middle stories(6-15) and the high stories(16~24), when the distance between buildings decreased from the current measurement, 1.0H, to 0.8H, the analysis indicated that 28% of daylight and 7% of view efficiency were reduced. In the building arrangements, an order of the best residential environment was followed in this sequence; balanced arrangement of flat type as the best, combined arrangement between L-shape and tower types, balanced arrangement of tower type, combined arrangement between flat and Y-shape types, grid arrangement of flat type, and combined arrangement between Y-shape and tower types as the least.

활성탄을 첨가한 콘크리트벽돌의 물리적 특성 및 환경 성능 평가에 관한 연구 (A Study on the Physical Properties and Environment Efficiency Evaluation in Activated Carbon Concrete Bricks)

  • 우종권;홍상희;전경빈;류현기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.47-51
    • /
    • 2006
  • Modern residing equipment developed much quantitatively along with economic growth but improvement for agreeable residing space of indoor environment is insufficient situation yet. Also, the latest sick-building syndrome discharging room contaminant such as Formaldehyde, toluene, radon etc. built house or buildings newly human body threaten. Radon of them is real condition that raise origination of lung cancer next to smoke. So, wish to in this research by one of solution way of these problems adsorption performance and specie performance excellent activated carbon to concrete bricks for deconstipating suppository that is room finish fare mix and examine closely after grasp physical, mechanical special quality, hazardous substance and specie performance effect. According to result that estimate environment efficiency evaluation, the $CO_2$ absorption amount displayed decrease effect more than about 90% in activated carbon metathesis rate 40% and radon release amount displayed tendency that decrease about $76{\sim}96%$ in activated carbon metathesis rate 40%.

  • PDF

환경친화형 농촌화장실의 적용가능성 평가 연구 (Evaluation of Application possibility of Environment-friendly Rural Toilet)

  • 강방훈;조순재;김상범;김혜민
    • 농촌계획
    • /
    • 제9권2호
    • /
    • pp.7-11
    • /
    • 2003
  • This study was conducted to evaluate the application possibility of environment-friendly rural toilet developed by NRLSI (National Rural Living Science Institute). The evaluation tests of rural toilet consist of composting efficiency, component analysis of odor, and economic efficiency. The test showed that the remaining quantity of wastes was only 14.7% during 10 months. The ammonium gas, main component of ill odor, was not measured, and the other components or odor were significantly detected less than those in pit toilet. The saved PVC (Present Value Cost) of the toilet management cost for thirty years is about 2,457,000 wons compared with flushing toilet supported by a single sanitation facility.

농촌개량주택의 물리적 환경수준 진단에 관한 연구 (The Evaluation on Physical Environment Level in Renovated Rural Houses.)

  • 윤정숙;전영미
    • 한국농촌생활과학회지
    • /
    • 제5권1호
    • /
    • pp.19-29
    • /
    • 1994
  • The purpose of this dissertation is to develop a tool for enviromental evaluation which measures a level of physical quality in renovated rural houses and to find out the physical environment conditions of the renovated houses in rural area. To achieve these purposes, criteria for the evaluation of physical environment were built up based on practical knowledge which have been found in books and through the fold survey. Elements of evaluation tool consists of Safety, Health, Efficiency that are basic elements in the Hygienic Quality of Housing in WHO. As a results of this study, a three-level of physical environments suggested that a basic level, a inductive level and a proper measure level in renovated rural houses.

  • PDF

지표대기 미세먼지 정화를 위한 식물체 음이온 발생량 분석 및 음이온의 미세먼지 기대정화지수 평가 (Evaluation on the Expected Purification Efficiency of Air Ion and Analysis on the Generated Amount of Negative Air Ions by Plants for the Purification of Particulate Matter in Air)

  • 오득균;주진희
    • 한국환경과학회지
    • /
    • 제29권6호
    • /
    • pp.623-631
    • /
    • 2020
  • This study analyzes the effect of negative air ions on the concentration of airborne particulate matter and evaluates the expected purification efficiency of open spaces for particulate matter by investigating the amount of negative air ions generated by plants. This study establishes a negative air ion generation treatment environment, plant environment, and control environment to measure the purification efficiency of particulate matter under the conditions of each, analyzing the expected purification efficiency by designing a particulate matter purification model. Results show that the amount of generated negative air ion according to environment was negative air ion generation treatment environment > plant environment > control environment; this order also applies to the particulate matter purification efficiency. Moreover, it took 65 min for the negative ion generation treatment environment, 90 min for the plant environment, and 240 min for the control environment to reach the standard expected purification efficiency of particulate matter concentration of 960 mg/㎥ for PM10. For PM2.5, with the designated maximum concentration of 700 mg/㎥, it took 60 min for the negative ion generation treatment environment, 80 min for the plant environment, and more than 240 min for the control environment. Based on these results, the expected purification efficiency compared to the control environment was quadrupled in the negative ion generation treatment environment and tripled in the plant environment on average.

A Study on the Productivity Measurement and Effect Factors of Management Evaluation in Public Firms with a Focus on the Port Authorities

  • Eom, Ki-Yong;Ahn, Ki-Myung
    • 한국항해항만학회지
    • /
    • 제44권5호
    • /
    • pp.400-406
    • /
    • 2020
  • In this study, we first measured the malmquist productivity index by DEA among the Korean public firms. Second, there are 12 public corporations whose productivity (MPI) has decreased compared to 2014. This is mainly because of a decrease in productivity, as well as a decrease in the technical efficiency change index (TECI), impacted by the internal environment, and the increase in productivity because of an increase in the technology change index (TCI) impacted by the external environment. Finally, the analysis of the impact on the management assessment scores showed that the productivity (MPI), scale efficiency (CRS), size of sales, operating profitability, and total capital investment efficiency are significantly related (+), except for the asset turnover, which is a static financial ratio. Meanwhile, the management evaluation scores between the high-productivity public corporations and low-performing public corporations were significantly discriminating. Thus, it is confirmed that the nation's state-run companies must manage their MPIs in a time series to score high in management evaluation.

광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증 (Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED)

  • 차광석;김회서
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

생태적 계획요소별 설문분석을 통한 시공성과 경제성의 평가 (Construction Technique and Economical Efficiency Evaluation on the Questionnaire Survey by Factors of Ecological Plan)

  • 박준모;최병주;김옥규
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2006년도 정기학술발표대회 논문집
    • /
    • pp.648-653
    • /
    • 2006
  • 현대의 지구환경은 무차별적인 산업화로 인한 공해로 오염되어가고 있다. 또한, 생태계 환경을 고려하지 못한 과밀화된 도시는 인간의 주거환경을 심각하게 위협하고 있는 실정이다. 따라서 '환경적으로 건전하고 지속가능한 개발(ESSD)'을 위하여 국내외에서 많은 연구를 진행하고 있다. 그러나 국내에서는 우리의 환경에 적합한 모델의 개발이나 이를 위한 계획요소의 연구가 이루어지지 않는 등 관련체계가 잡혀져 있지 않은 실정이다. 본 연구에서는 생태도시와 단지조성을 위한 생태적 계획요소에 대해 전문가 설문을 실시하였다. 많은 이들이 생태적인 개발에 대한 필요성은 인식하고 있지만, 아직 많은 부분에서 현실성이 부족하다는 것이 큰 문제점으로 지적되었다. 한편으로는 환경에 관한 교육과 홍보 및 성공적인 모델과 구축과정의 개발이 선행되어야 할 것으로 판단된다.

  • PDF

전동기 시스템의 효율 평가 규격 및 규제 현황 연구 (A Study on the Efficiency Evaluation Standard and Regulation for Electric Motor Systems)

  • 전희득;박한석;김대경;우경일
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1618-1625
    • /
    • 2016
  • Electric motor systems account for more than half of all electric systems and the amount of energy consumption of those is almost 70 percent of total energy consumption of electric motor systems in industry. As electric motor systems are very responsible for global electricity savings and environment protection. Many international organizations are supporting standards and policy development processes to improve the efficiency of electric motor systems. Many standards are being developed at technical committee of IEC that has been required in order to support the implementation of efficiency regulations. High efficiency standards and levels for electric motor systems are slowly being introduced and compulsory in many countries. Therefore understanding the international efficiency evaluation standards and the regulation of electric motor systems of each country is important. This paper presents the current status and trends of international evaluation standards and regulations about the efficiency of electric motor systems.