• 제목/요약/키워드: Environment chamber

검색결과 845건 처리시간 0.024초

하수처리장에서의 암모니아 플럭스 산정을 위한 물질전달모형 개발 (Development of Mass Transfer Models for Ammonia Flux Estimation from Sewage Treatment Plants)

  • 사재환;전의찬;정재학
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.701-711
    • /
    • 2006
  • Sewage treatment plants located near to large cities emit extremely higher concentration of odorous materials. This study evaluated flux profiles of ammonia emitted from the water surface of sewage treatment plants using a dynamic flux chamber. Also, an ammonia overall mass transfer coefficient and a mass transfer model was developed in order to estimate fluxes of ammonia using environment parameters and the flux from the sewage treatment plants. The developed mass transfer model was evaluated through a fitness analysis. Comparison modeled flux applying empirical overall mass transfer coefficients of ammonia and measured ammonia flux show a high linearity with 0.977. The flux ratio of 1.282 demonstrated highly statistical fitness, also. Modeled flux using the mass transfer model was compared with measured flux. In result, it indicated that empirical overall mass transfer coefficients were similar to measured flux. The mass transfer model using the empirical overall mass transfer coefficient developed in this study was proved to be an easy and effective method to make accurate and precise predictions for ammonia flux discharged from sewage treatment plants.

개별환경제어(PEM)시스템의 열적 특성 및 성능개선에 관한 연구 (The Experimental Study on Thermal Characteristics of PEM(Personal Environment Module) System)

  • 조성환;장철용;태춘섭
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.439-447
    • /
    • 2000
  • The PEM(Personal Environment Module) system is an individual air conditioning system developed in order to improve thermal comfort in office buildings. In this study, thermal characteristics of a PEM system have measured experimentally and compared with UFAC(Under Floor hir Conditioning) system in the EC(Environment Chamber) constructed in KIER. Results showed that the PEM system was better than UFAC system for thermal comfort and energy conservation.

  • PDF

대기중 이산화황 관측 방법들의 실측 비교 연구 (An Intercomparison of Atmospheric SO$_{2}$ Measurement Techniques)

  • 김경렬;이동수;이강웅
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.587-591
    • /
    • 1996
  • An intercomparison experiment was implemented to assess the uncertainties and precisions om atmospheric SO$_{2}$ measurement techiques including a pulsed fluorescence (P-F), a diffusion-scrubber /ion chromatography (D-I), and a mist-chamber/ion chromatography (M-I). Each of those three techniques was investigated by researchers at Seoul National University, Yonsei University, and Hankuk University of Foreign Studies, respectively. The concentrations of atmospheric SO$_{2}$ were determined concurrently using three independent measurement techniques at the Seoul National University campus, Korea during Nov.22 to Dec.2, 1995. While the results from the P-F and D-I techinques showed the very close agreements (within +-5%) throughout the experiment period, M-I technique showed systematically smaller values (up to 30%) than the other two techniques. Although sources of larger discrepancy between different techniques were mot identified, the lower SO$_{2}$ values of the M-I method may be related to the errors associated with sample collection effciency, mass flow rate measurements, and standardization of ion chromatography.

  • PDF

오존 간이측정기에 대한 연구(I)-필터의 민감도 (A Study of Ozone Passive Sampler(I)-Sensitivity on Filter Substrate)

  • 정상진
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.383-391
    • /
    • 2002
  • Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.

고압상태에서의 디젤연료분무의 연소 및 매연가스배출 특성 (Combustion and Emission Characteristics of Diesel Spray in High-Pressure Environment)

  • 권영동;김용모;김세원;박신배
    • 한국분무공학회지
    • /
    • 제2권1호
    • /
    • pp.18-28
    • /
    • 1997
  • The present study is mainly aiming at numerically analyzing the combustion and emission characteristics of the diesel spray in a high-pressure environment. Computations are peformed for the peak chamber pressure with range from 4.08 MPa to 162 MPa. Numerical results indicate that the pressure increase in combustion chamber significantly influences the mechanism for droplet dynamics and mixing characteristics, spray penetration autoignition, flame lift-on height and the propagation or fuel vapor and flame. By increasing the ratio or the ambient density to injected liquid density, the fuel-air mixing rates and the burning rates increase and the $NO_x/soot$ emission level decreases.

  • PDF

우포늪의 메탄 발생량 추정을 위한 관측 연구 (Observational Study to Estimate the Emission of Methene at Upo-swamp)

  • 이정아;김해동;이부용
    • 한국환경과학회지
    • /
    • 제20권3호
    • /
    • pp.301-308
    • /
    • 2011
  • The temporal variations of methene emission and its relation to air temperature were investigated in Upo-swamp during June 2007 through July 2008. To perform this study, the methene emission and air temperature were observed using the buoy-type chamber and automatic weather observation system(AWS), respectively. The methene emissions were much during summertime(June~August). The maximum value(about 73.4 mg/$m^2$/hr) appeared at August. The emission diminished by degrees after August. The methene emissions were fewer from September to May of the following year. The peak value(73.4 mg/$m^2$/hr) of the methene emission is very much compared to that of rice pappy field known as about 28.7 mg/$m^2$/hr.

흄토치 성능 평가에 관한 연구 (Performance Assessment of Fume Extracting Welding Gun)

  • 최찬기;김태형;하현철;원정일
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.90-99
    • /
    • 1999
  • Fume extracting welding gun is one of the promising options for reducing the welder's fume exposure. The performance of the gun was assessed on the basis of capture efficiency. Capture efficiencies were measured in a test chamber recommended by American Welding Society. The overall capture efficiency was turned out to be above 95%. But it did not include the effect of crossdraft existing in the real work environment because all experiments were conducted in a closed chamber. It thus needs more work in the future. In addition, the future directions for improving the pres ent commercial techniques of the gun were discussed.

  • PDF

환경변화에 따른 전기이륜차의 에너지소비효율에 관한 연구 (Study of Energy Consumption Efficiency of Electric Two-wheeled Vehicle by Change of Environment Variation)

  • 길범수;김강출
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.56-63
    • /
    • 2012
  • Environment has become a main issue nowadays. People began to show big interest in "futuristic means of transportation", which is an efficient method in $CO_2$ emissions reduction and decreasing use of oil. Due to the noise and emissions of two-wheel vehicle of internal combustion engine, electric two-wheeled vehicles have been supplied in downtown. The electric two-wheeled vehicles use battery as power source. The performance of lithium-ion battery changes as the ambient temperature changes. In this paper, analysis of performance variance of electric two-wheeled vehicles influenced by the temperature using the chassis dynamometer and the environmental chamber was carried out.

대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가 (Field Validation of alternative extraction method for the determination of airborne MWFs)

  • 정지연;백남원
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

잔향챔버내에서 공간 상관도에 의한 MIMO 시스템의 성능평가 (Performance Evaluation of MIMO System by Spatial Correlation in Reverberation Chamber)

  • 김종성
    • 전자공학회논문지
    • /
    • 제51권10호
    • /
    • pp.26-33
    • /
    • 2014
  • 잔향챔버내에 모드 스터러가 회전하는 조건에서 $2{\times}2$ MIMO 시스템에 대한 다중경로 페이딩에 대한 공간 코릴레이션을 구한다. 잔향 챔버내에서 $2{\times}2$ MIMO 시스템에 기초한 다중경로 환경에 대한 공간 상관도를 계산한다. 이 방식은 안테나 다이버시티 시스템에서 다이버시티 이득에 대한 가능성을 정량화하는데 이용할 수 있다.