• Title/Summary/Keyword: Envelope peak

Search Result 104, Processing Time 0.023 seconds

Analysis of X-Band Link Performance Degradation Caused by Adjacent Satellite

  • Park, Durk-Jong;Ahn, Sang-Il;Chun, Yong-Sik;Kim, Eun-Kyou
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • As more satellites are designed to downlink their observed image data through the X-band frequency band, it is inevitable that the occupied bandwidth of a target satellite will overlap with that of other X-band downlink satellites. For sun-synchronized low earth orbit satellites, in particular, it can be expected that two or more satellites be placed within the looking angle of a ground station antenna at the same time. Due to the overlapping in the frequency band, signals transmitted from the adjacent satellites act as interferers, leading to degraded link performance between target satellite and ground station. In this paper, link analysis was initiated by modeling the radiation pattern of ground station antenna through a validated Jet Propulsion Laboratory peak envelope model. From the relative antenna gain depending on the offset angle from center axis of maximum antenna directivity, the ratio of received interference signal level to the target signal level was calculated. As a result, it was found that the degradation increased when the offset angle was within the first point of radiation pattern. For a 7.3 m antenna, serious link degradation began at an offset angle of 0.4 degrees. From this analysis, the link performance of the coming satellite passes can be recognized, which is helpful to establish an operating procedure that will prevent the ground station from receiving corrupted image data in the event of a degraded link.

Analysis of Singer's Formant & Close Quotient During Change of the Larynx Position (후두위치의 변화에 따른 Singer's Formant와 성대접촉률의 변화 연구)

  • Nam, Do-Hyun;Choi, Seong-Hee;Choi, Jae-Nam;Chun, Suck-Pil;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.98-111
    • /
    • 2004
  • Background and Objectives : The purpose of this study is to analyze the difference of Fundamental Frequency(Hz), Closed Quotient(Qx ; %), Intensity(dB), Vocal tract length and width(cm), formant frequency(Hz), level of formant frequency(dB) depending on the larynx position. Materials and Methods : One professional male singer(career : 28 years) produced sustained vowel /a/,/e/,/i/,/o/,/u/ in two larynx position (higher, lower) with Dr. Speech and video fluoroscopy was used to quantify the vocal tract morphology. Results : In lower larynx position, CQ is increased 9.8% and Intensity is increased about 10% and level of Formant Frequency is increased. And also Vocal tract length is longer 2.4cm, Vocal tract width(Anterior width : 0.4cm, lateral width : 0.2cm) is wider than in higher larynx position. Conclusions : Singer's formant has a prominent spectrum envelope peak near 2400-2600Hz by clustering of F3, F4 and F5 near 3400Hz in lower larynx position.

  • PDF

A Research on a Cross Post-Distortion Balanced Linear Power Amplifier for Base-Station (기지국용 Cross Post-Distortion 평형 선형 전력 증폭기에 관한 연구)

  • Choi, Heung-Jae;Jeong, Hee-Young;Jeong, Yong-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1262-1270
    • /
    • 2007
  • In this paper, we propose a new distortion cancellation mechanism for a balanced power amplifier structure using the carrier cancellation loop of a feedforward and post-distortion technique. The proposed cross post-distortion balanced linear amplifier can reduce nonlinear components as much as the conventional feedforward amplifier through the output dynamic range and broad bandwidth. Also the proposed system provides higher efficiency than the feedforward. The capacities of power amplifier and error power amplifier in the proposed system are analyzed and compared with those of feedforward amplifier. Also the operation mechanisms of the three kind loops are explained. The proposed cross post-distortion balanced linear power amplifier is implemented at the IMT-2000($f_0=2.14\;GHz$) band. With the commercial high power amplifiers of total power of 240 W peak envelope power fer base-station application, the adjacent channel leakage ratio measurement with wideband code division multiple access 4FA signal shows 18.6 dB improvement at an average output power of 40 dBm. The efficiency of fabricated amplifier Improves about 2 % than the conventional feedforward amplifier.

Design of Cartesian Feedback Loop Linearization Chip for UHF Band (UHF 대역용 Cartesian Feedback Loop 선형화 칩 설계)

  • Kang, Min-Soo;Chong, Young-Jun;Oh, Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.510-518
    • /
    • 2010
  • In this paper, the designed and implemented results of CFL linearization chip which can be used in mobile radio and TRS terminal of UHF band(380~910 MHz), using $0.6\;{\mu}m$ BiCMOS process based on Si, are shown. As gain control circuits for modifying transmit power are inserted not only in feedback path but also in forward path, the stability of CFL is maintained. And, DC-offset correction function of S/H structure, which is suitable for walkie-talkie PTT operation and is easily implemented, is realized. The performance test results of transmitter show that the regulation of FCC emission mask at PEP 3 W(34.8 dBm) is satisfied when the CQPSK modulated signal is fed and more than 30 dBc improvement of 3rd order IMD is achieved when two-tone signal is inputted.

Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences (실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성)

  • Kim, Jeonghoon;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.

Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

Development of a 2.14-GHz High Efficiency Class-F Power Amplifier (2.14-GHz 대역 고효율 Class-F 전력 증폭기 개발)

  • Kim, Jung-Joon;Moon, Jung-Hwan;Kim, Jang-Heon;Kim, Il-Du;Jun, Myoung-Su;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.873-879
    • /
    • 2007
  • We have implemented a highly efficient 2.14-GHz class-F amplifier using Freescale 4-W peak envelope power(PEP) RF Si lateral diffusion metal-oxide-semiconductor field effect transistor(LDMOSFET). Because the control of the all harmonic contents is very difficult, we have managed only the $2^{nd}\;and\;3^{rd}$ harmonics to obtain the high efficiency with simple harmonic control circuit. In order to design the harmonic control circuit accurately, we extracted the bonding wire inductance and drain-source capacitance which are dominant parasitic and package effect components of the device. And then, we have fabricated the class-F amplifier. The measured drain and power-added efficiency are 65.1 % and 60,3 %, respectively.

Multiple-Symbol Differential Detection Scheme of Differentially Encoded MultiPhase Clipped MultiCode CDMA System (차동 부호화된 MultiPhase Clipped MultiCode CDMA 시스템의 수신 성능 개선을 위한 다중 심볼 차동 검출 방식 연구)

  • 이병하;안철용;김동구;조진웅
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10A
    • /
    • pp.807-815
    • /
    • 2003
  • MultiCode-CDMA (MC-CDMA) system of chip level MPSK incorporating with clipper (MP-CDMA)[l] shows constant envelope signal which can mitigate the performance degradation due to nonlinear transmit amplifier. In this paper, modulation is modified to carry out differential encoded MPSK rather than MPSK. The modified system is called DMP-CDMA. DMP-CDMA using differential detection has advantages on receiver complexity and pilot overhead. However, it is inferior to coherent detection by about 4.0dB due to inherent power inefficiency of noncoherent detection and the error propagation. Multiple symbol differential detection is employed in order to improve DMP-CDMA using differential detection. As the result, the performance of DMP-CDMA system is improved about 3.6dB compared to differential detection.

Comparison of Vibration Characteristics of Cargo Bikes on General Roads and Bicycle Roads (일반도로와 자전거도로에서의 카고바이크 화물 적재함 진동 특성 비교)

  • Dong Yul Kim;Myenog Guk Yu;Heng Suk Lee;Sang Min Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.175-179
    • /
    • 2023
  • This paper analyzes the vibration characteristics within the cargo compartment of a three-wheeled cargo bike when used on both regular roads and dedicated bicycle lanes. When cargo is loaded into the cargo compartment of a cargo bike and driven on the road, the shocks and vibrations transmitted from the ground can potentially affect the transported goods and even lead to product damage. As the vibration characteristics applied to the cargo compartment may vary depending on the condition of the road, vibration sensors were attached to the cargo bike's cargo compartment for data collection during operation on different road types. According to KS T ISO 13355 standards, the cargo bike can withstand vibrations within the range of 10 Hz to 60 Hz when operating on both bicycle lanes and regular roads. However, it is observed that there are peaks exceeding the profile in the frequency range of 3-6 Hz. In the 70-200 Hz range, the profile is exceeded on both regular roads and bicycle lanes, with a tendency for higher exceedance on bicycle lanes. The Grms value within the frequency range of KS T ISO 13355 is 5.926 m/s2 (0.604 Grms). When operating on bicycle lanes with cargo, the Peak envelope optimization PSD value is 6.553 Grms, while on bicycle lanes, it is 7.708 Grms, indicating a difference of at least tenfold.

Predicting Parturition Time through Ultrasonic Measurement of Posture Changing Rate in Crated Landrace Sows

  • Wang, J.S.;Wu, M.C.;Chang, H.L.;Young, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.5
    • /
    • pp.682-692
    • /
    • 2007
  • This study presents an automatic system to predict parturition time in the crated sows. The system relies on ultrasonic transducers mounted from above along the length of the crate. Using a 40 kHz time of flight (TOF) single envelope wave, the momentary distances between the sensors are measured. Therefore, the local momentary height of the sow and the momentary posture, i.e. standing posture (SDP), kneeling posture (KP), sitting posture (STP) and lateral lying posture (LLP) are determined. Crated sows change their postures from standing to lying and vice versa which follows a characteristic pattern. As parturition approaches, sows exhibit uneasiness, restlessness and the stand up sequence (SUS, the posture transition from LLP to SDP) rate increases because of labor pains. In time series, the SUS rate demonstrates a peak and it happens approximately 0-12 h before parturition. In this paper, the basic parturition threshold value method (BPTVM) and the same hour method (SHM) are proposed for predicting parturition, both of which are based on the SUS rate. The BPTVM mainly detects the peak of the SUS rate. As the SUS rate exceeds the threshold value, the parturition becomes predictable. Moreover, the SHM calculates the difference in the SUS rates between a particular time of day and the corresponding time of the preceding day. Compared to the BPTVM, the SHM can eliminate the circadian rhythm of the SUS rate influenced by feeding behavior. Using the SHM the parturition can be approximately predicted within hours. In an attempt to define the threshold parameters of predicting parturition, a data set with 32 sows of the SUS rate are used to estimate assumable predicting probability. The results show the assumable probability of the parturition prediction within 9 h is 96.9% for the SHM and 84.4% for the BPTVM. Moreover, the SHM can even reach a 75% probability of prediction within three hours of parturition. We conclude that the SHM is more accurate and is more useful for parturition time prediction. When parturition is detected, the proposed algorithm generates a warning signal which can inform human personnel to protect the mother and newborn piglets.