Development of the Scramjet engine Test Facility(SeTF) in Korea Aerospace Research Institute (한국항공우주연구원 스크램제트 엔진 시험설비의 개발)

  • Lee, Yang-Ji;Kang, Sang-Hun;Oh, Joong-Hwan;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.3
    • /
    • pp.69-78
    • /
    • 2010
  • Korea Aerospace Research Institute started on design and development of a hypersonic air-breathing engine test facility from 2000 and completed the test facility installation in July 2009. This facility, designated as Scramjet engine test facility(SeTF), is a blow-down type high enthalpy wind tunnel which has a pressurized air supply system, air heater system, free-jet test chamber, fuel supply system, facility control/measurement system and exhaust system. In this paper, details of the specifications, and configuration of the SeTF are described. For verifying characteristics of the SeTF, wind tunnel tests are now on progress and some of the data are also described.

Effects of Sikhe dietary fibers on the Rice Starch gelatinization and Retrogradation properties (식혜식이섬유가 쌀전분의 호화와 노화 특성에 미치는 영향)

  • 전은례;김경애;정난희
    • Korean journal of food and cookery science
    • /
    • v.18 no.2
    • /
    • pp.157-163
    • /
    • 2002
  • The gelatinization and retrogradation properties of rice starch added with dietary fibers from sikhe were investigated. The pasting temperature and setback of starch measured by using a rapid visco analyzer were increased by the addition of the fiber, whereas the peak viscosity, trough viscosity, end viscosity, breakdown and consistency were lowered. The onset temperature of starch measured by a DSC was increased, but the enthalpy of gelatinization of the starch was decreased as the addition of fiber increased. The melting peak temperature of the retrograded starch gels was 41∼46$\^{C}$ as measured by a DSC. The melting enthalpy of the control retrograded starch gel was increased while storing for 1, 3 and 7 days at 4$\^{C}$, but that of containing sikhe fiber showed no differences.

A Study on Natural Dyeing (5) - Adsorption Properties of Berberine for Silk Fabrics - (천연염색에 관한 연구(5) - 황벽색소 베르베린의 견에 대한 염착특성 -)

  • Kim, Hye In;Park, Su Min
    • Textile Coloration and Finishing
    • /
    • v.14 no.2
    • /
    • pp.85-85
    • /
    • 2002
  • The interaction between berberine and tannin in aqueous solution was investigated spectrophotometerically. The dyeing mechanism of silk fabrics (control and tannin treated silk fabrics) with berberine was based on thermodynamic parameters obtained from equilibrium adsorption experiments. In adsorption spectra of aqueous solution of berberine and tannin mixture two isosbestic points (328nm, 357nm) were found and the mole fraction of reaction of components was 1:1. Initial dyeing rates were increased and the diffusion of dye was more effective by tannin treatment. Without regard to tannin treatment the adsorption isotherm of berberine was the langmuir type except high temperature, 80℃. By tannin treatment the saturation dye uptake was increased, the increase of dye uptake appeared to be a result of entropy change rather than enthalpy change. All these results can be interpreted by the hydrophobic interaction between berberine and silk treated with tannin and it is reasonable to conclude that not only the ionic force, but also the hydrophobic interaction contributes to the binding of berberine and tannin treated silk treated with tannin.

A Study on Natural Dyeing (5) - Adsorption Properties of Berberine for Silk Fabrics - (천연염색에 관한 연구(5) -황벽색소 베르베린의 견에 대한 염착특성 -)

  • 박수민;김혜인
    • Textile Coloration and Finishing
    • /
    • v.14 no.2
    • /
    • pp.9-17
    • /
    • 2002
  • The interaction between berberine and tannin in aqueous solution was investigated spectrophotometerically. The dyeing mechanism of silk fabrics (control and tannin treated silk fabrics) with berberine was based on thermodynamic parameters obtained from equilibrium adsorption experiments. In adsorption spectra of aqueous solution of berberine and tannin mixture two isosbestic points (328nm, 357nm) were found and the mole fraction of reaction of components was 1:1. Initial dyeing rates were increased and the diffusion of dye was more effective by tannin treatment. Without regard to tannin treatment the adsorption isotherm of berberine was the langmuir type except high temperature, $80^\circ{C}$. By tannin treatment the saturation dye uptake was increased, the increase of dye uptake appeared to be a result of entropy change rather than enthalpy change. All these results can be interpreted by the hydrophobic interaction between berberine and silk treated with tannin and it is reasonable to conclude that not only the ionic force, but also the hydrophobic interaction contributes to the binding of berberine and tannin treated silk treated with tannin.

A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능예측에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Jin-Hyuck
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.294-299
    • /
    • 2005
  • In order to control indoor air quality and save energy. it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. Paper heat exchanger can recover $50{\sim}70$ of the enthalpy difference between supply and exhaust air. The purpose of this research is to obtain the experimental correlations for the friction factor, heat transfer coefficient, mass transfer coefficient and permeance of paper heat exchanger, which can be used for the performance prediction of the paper heat exchanger. Pressure drop at various velocities and heat transfer rate at various dry-bulb temperatures, relative humidities, and specific humidities are measured to make experimental correlations. The results of prediction using correlations show fairly good agreement with experimental data.

  • PDF

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

The Use of Demand Controlled Ventilation in Multi-Purposed Facility (수요기반 환기량 조절법 (DCV)의 다중이용시설 적용방안)

  • Jeong, Jae-Weon;No, Sang-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.111-116
    • /
    • 2008
  • The objective of this paper was to show the possibility of demand-controlled ventilation (DCV) using the current Korean ventilation standard for multi-purposed facilites. Two attractive DCV approaches; $CO_2$-DCV and RFID-DCV were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with enthalpy recovery device. A numerical model for predicting realtime occupant number, ventilation rate, and $CO_2$ concentration under given conditions was developed using a commercial equation solver program. It was found that the current ventilation standard causes unstable ventilation system control in DCV applications, especially under $CO_2$-DCV. It is because the ventilation rate (per person) used in Korea is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupant and building itself, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order for solving this problem, current Korean ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to DCV significantly.

  • PDF

A Study on Building Energy Saving using Outdoor Air Cooling by Load Prediction (부하예측 외기냉방에 의한 건물에너지 절약에 관한 연구)

  • Kim, Tae-Ho;Yoo, Seong-Yeon;Kim, Myung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.43-50
    • /
    • 2017
  • The purpose of this study is to develop a control algorithm for outdoor air cooling based on the prediction of cooling load, and to evaluate the building energy saving using outdoor air cooling. Outdoor air conditions such as temperature, humidity, and solar insolation are predicted using forecasted information provided by the meteorological agency, and the building cooling load is predicted from the obtained outdoor air conditions and building characteristics. The air flow rate induced by outdoor air is determined by considering the predicted cooling loads. To evaluate the energy saving, the benchmark building is modeled and simulated using the TRNSYS program. Energy saving by outdoor air cooling using load prediction is found to be around 10% of the total cooling coil load in all locations of Korea. As the allowable minimum indoor temperature is decreased, the total energy saving is increased and approaches close to that of the conventional enthalpy control.

Retarded Retrogradation Effect of Garaetteok with Apple Pomace Dietary Fiber Powder (사과박 식이섬유분말을 첨가한 가래떡의 노화억제효과)

  • Park, Young-Kyoung;Kim, Hee-Sun;Park, Hye-Young;Han, Gwi-Jung;Kim, Myung-Hwan
    • Journal of the Korean Society of Food Culture
    • /
    • v.26 no.4
    • /
    • pp.400-408
    • /
    • 2011
  • This study was performed to analyze the retarded degree of Garaetteok retrogradation added with different ratios 0-15% (w/w) of apple pomace dietary fiber powder (DFP). SEM (${\times}$500) showed that air cell size on the Garaetteok surface increased as DFP content increased, whereas control had a compact structure without air cells. The degrees of Garaetteok retrogradation after 3 days at 4 and 25$^{\circ}C$ by ${\alpha}$-amylase iodine method were 57.44 and 41.55% for control, respectively. On the other hand, those of 15% DFP Garaetteok were 28.38 and 15.05%, respectively. Enthalpy changes (${\Delta}$E) by DSC of control, 10 and 20% DFP Garaetteok after 3 days of storage at 4$^{\circ}C$ were 4.41, 4.17, and 3.80 J/g, respectively, whereas those at 25$^{\circ}C$ were 2.14, 1.04, and 0.72 J/g. Hardness of 15% DFP Garaetteok was around 48% compared to that of control after 3 days of storage at 25$^{\circ}C$. Increasing DFP content from 0 to 15% decreased L color value from 86.2 to 55.1, whereas a and b values increased from -1.9 to 8.9 and from 5.3 to 20.8, respectively. In a sensory intensity test, hardnesses of 15% DEP Garaetteok were significantly different at 1 and 0.1% compared to those of control after production and followed by storage for 3 days at 4$^{\circ}C$, respectively.

Energy Saving Effect of the Night Purge Control using ERV in a School Building (전열교환형 환기시스템을 이용한 학교건물의 나이트 퍼지 적용 효과 분석)

  • Kim, Su-Yeon;Won, Jung-kwan;Kim, Jae-Hyung;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.421-427
    • /
    • 2016
  • The indoor temperature of a building increases during the day due to solar radiation. This behavior is significant in school buildings that are finished with high thermal capacity materials. Moreover, in school buildings, windows cannot be opened until the class has finished owing to the security policy of schools. Consequently, classrooms maintain a high temperature throughout the morning. It is thus important to remove the indoor heat before the commencement of classes in order to reduce the cooling energy needed. The Energy Recovery Ventilator (ERV) system is currently being installed in school buildings for ventilating the classrooms. Night-purge control using ERV can be a good strategy to cool the classroom in advance of the operation of the cooling system. However, the optimal operation method of the ERV for night-purge control has not yet been reported. In this study, the effect of night-purge control with ERV in school buildings is analyzed by simulation method. The results of this study showed that the energy saving effect of night-purge control with ERV is most effective in the case of 2 hours operation prior to the commencement of the first lass and when enthalpy based outdoor air cooling is used.