• Title/Summary/Keyword: Enterprise Disaster Management Standards

Search Result 7, Processing Time 0.023 seconds

A study on the legal status and problem improvement of enterprise disaster management standard (기업재난관리표준의 법적성격과 문제점 개선에 관한 연구)

  • Rhee, Sangsoo;Jung, Uiyun;Park, Jeonghun;Cheung, Chongsoo
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.115-121
    • /
    • 2018
  • Purpose: The purpose of this study is to identify the legal status of enterprise disaster management standards established as part of business continuity management and to ensure resilience, and to improve the problem of application of industry disaster management standards in related industries. Method: We collected relevant data for the study and conducted a literature review on the logistical definition of laws and academic systems such as constitution and enterprise disaster reduction law, and HLS structure. Results: It has been confirmed that the enterprise disaster management standards in the Enterprise Disaster Management Standard are higher in the legal status than the ISO 22301: 2012 international standard. Conclusion: Through this study, it is necessary to establish a development direction of application and related regulations by clarifying the enterprise disaster management standard according to the enterprise disaster reduction law.

A Study on the Level of BCMS(Business Continuity Management System) of Small and Medium Enterprises (중소기업의 재해경감활동관리체계 수준진단(Checklist)에 관한 연구)

  • Lee, Mi Sun;Kim, Min Ji;Kim, Do Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.122-128
    • /
    • 2017
  • Recently, accidents such as human accidents are increasing rapidly due to natural disasters and changes in social conditions due to abnormal weather. As a result, damage has been causing massive damage unlike the past. In the case of small and medium enterprises excluding financial institutions and big company, there is no system for prevention and restoration for stable operation from various risks such as human and natural disasters. As the current disaster continues, public and private companies have raised the need for BCM, and with the introduction of the ISO22301 certification system, the company has been establishing and operating Enterprise Disaster Management Standards in the Ministry of Public Safety and Security since 2007. However, in most SMEs, it is hard to bear the input of internal labor and investment cost, and there is a lack of personnel with expertise to conduct BCM diagnosis. Therefore, in this paper, we will study the diagnosis level of enterprise continuity plan which is commonly used in Korea and abroad. Based on this, we will study the BCM system diagnosis method which can be applied to small and medium enterprises in Korea efficiently.

Research on Improving the Method of Establishing a Disaster Reduction Activity Management System linked with In-house Suppliers (사내 공급자와 연계된 재해경감활동관리체계 구축방법 개선 연구)

  • Kim, Sang Duk;Kim, Chang Soo
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.365-374
    • /
    • 2021
  • Purpose: This study aims to study the reinforcement of the connection between the ordering agency and the in-house supplier's disaster reduction activity management system. Method: The requirements for the supplier strategy specified in the enterprise disaster management standard were identified, the application cases of agency A and supplier B were reviewed, and procedures for reinforcing the linkage of the disaster reduction activity management system were derived. Result: In order to clearly define the supplier strategy, which is a requirement of the enterprise disaster management standard, and to reinforce the linkage, it was studied that the procedure applied by the ordering agency and the supplier, and a standardized procedure for sharing the results produced by the procedure were necessary. Conclusion: Among the procedures for establishing a disaster reduction activity management system for in-house suppliers, an improvement plan was proposed to reinforce the linkage of important procedures, and the proposed contents and procedures were suggested to be reflected in the enterprise disaster management standards and related norms.

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

Analyzing Characteristic of Business District in Urban Area Using GIS Methods - Focused on Large-Scale Store and Traditional Market - (GIS 기법을 활용한 도시지역 상권 특성 분석 - 대형할인점과 전통시장을 중심으로 -)

  • SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.89-101
    • /
    • 2017
  • The study used GIS methods to analyze a business district consisting of traditional markets and large-scale stores, to determine the level of support needed for small enterprises in an urban area of Changwon-si, Gyeongsangnam-do. Data gathered on the area was analyzed using GIS tools such as Kernel density, Network analysis, and Huff modeling. Traditional markets are concentrated in areas where large-scale stores are located, and data analyses show that the number of consumer'use of large-scale stores (157,071) was three times that of traditional markets (59,953). One explanation for these results is that the large-scale stores are located either in densely populated areas or are adjacent to the traditional markets. Therefore, standards and regulations are needed to support small enterprise business districts. In the future, the results of this study can be used as a reference for planning and supporting traditional market business districts.

Effects of the Safety and Health Management System on the Performance of the Enterprise: Focus on the Electric Power Corporation (안전보건경영시스템의 운영방침이 기업성과에 미치는 영향: 전기공사업을 중심으로)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • This research is mainly aimed at finding out about the effects of the safety and health management system on corporate performance through systematic operation by efficiently allocating material and human resources within the company by participating all employees and stakeholders in order to prevent and maintain industrial accidents and the optimal working environment, and how to maintain and activate the safety and health management system at the center of electric contractors.The analysis results are as follows. First, management, organizational management and resource preparation will have a positive impact on the management capability of the electric power corporation. It was assessed that the more well-transmitted and understood within the organization, the better the construction plan, the better the equipment management status, the more positively the management capability of electric works was to be achieved. Second, management, organizational management and resource preparation will have a positive impact on corporate management performance.This seems to have a positive effect on a company's business performance when the standards of OHSAS are met with construction plan and construction equipment management are high as related information such as industrial safety and health laws are strengthened and companies' safety and health activities, advanced safety and culture are released to facilitate organizational management.Third, the management ability of the electric power corporation will have a mediated effect on the effect of management, organization management and resource preparation on the performance of the enterprise. This means that the direct effect of the independent variable management organization on corporate management performance is .401 The indirect effect is .168.658 shows that the direct effect of resource preparation on corporate management performance is .423, the indirect effect is .178 and the total effect.It was analyzed at 643.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.