• Title/Summary/Keyword: Enophthalmos

Search Result 73, Processing Time 0.025 seconds

Diagnosis and Treatment of Unilateral Maxillary Sinus Hypoplasia (편측 상악동 저형성증의 진단과 치료)

  • Kim, Soung-Min;Kim, Min-Keun;Kwon, Kwang-Jun;Lee, Suk-Keun;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.127-132
    • /
    • 2012
  • Maxillary sinus hypoplasia (MSH) is an uncommon clinical disease that represents a persistent decrease in sinus volume, which results from centripetal reaction of the maxillary sinus walls. We present a unilateral MSH case of a 46-year-old male patient with a history of nasal obstruction and headache for 3 years. He had a history of Caldwell Luc operation (CLOP) 10 years ago, and no enophthalmos, hypoglobus or facial asymmetry. After confirming the right diagnosis of MSH, filled with bone in the computed tomography scan, hyperplastic bone was removed by the CLOP approach. The uncinate process and infundibular passage were found to be degenerated and ostium was also examined to be obstructed under endoscopic confirmation. MSH can be mistaken for chronic maxillary sinusitis because of the plain x-ray appearance, so the aggravated state of MSH can be the result of surgeon's misjudgment. With additional literature reviews, this rare experience is first introduced in our Korean oral and maxillofacial surgery field.

A Clinical study of infraorbital wall fractures. (안와하부 골절의 임상적 연구)

  • Baek, Eun-Ho;Ko, Seung-O;Shin, Hyo-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.288-293
    • /
    • 2000
  • This study was aimed at furnishing the data of infraorbital wall fractures and aiding treatment. This is the retrospective study on infraorbital wall fractures. The patients were treated in the Dept. of Oral & Maxillofacial Surgery of Chon-Buk National University Hospital from Jan. 1, 1996 to Sep. 30, 1999. The result were as follows : Male predominated over female by a ratio of 3.57 : 1. The most common reason was traffic accident(64.1%). The elapsed time from injury to operation was average 10.4 days. The most frequent site of fractures was Zygomatico-Maxillary complex fracture(61.7%). The highest department of associated injuries was neurologic Dept.(52.3%). The complication after fractures were the ophthalmologic(20.3%), esthetic(14.8%), facial numbness(4.7%), etc in this order. The highest ophthalmologic complications was the enophthalmos(7%).

  • PDF

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.

Cone-beam computed tomographic imaging of silent sinus syndrome: A case series and a literature review

  • Manila, Nisha G.;Arashlow, Mehrnaz Tahmasbi;Ehlers, Scott;Liang, Hui;Nair, Madhu K.
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.365-371
    • /
    • 2020
  • While silent sinus syndrome (SSS) is familiar to otolaryngologists and ophthalmologists, it is a rare clinical entity in dentistry and is likely to be underdiagnosed due to dentists' lack of awareness of this condition. SSS presents a diagnostic challenge to dentists, as patients typically have no history of trauma or sinusitis. The characteristic feature of SSS is a gradual retreat of the maxillary sinus walls, resulting in enophthalmos and hypoglobus. Multidetector (multislice) computed tomography is the imaging modality of choice for SSS and other paranasal sinus diseases. Cone-beam computed tomography promises to be an alternative low-dose imaging modality. This report describes 3 cases of SSS in adults, who had no identified clinical symptoms except diminutive and opacified maxillary sinuses, as well as the inward bowing of the sinus walls as noted on cone-beam computed tomographic imaging.

Survey and Review of Blowout Fractures (안와벽 파열골절에 대한 임상적 고찰)

  • Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kywng Won;Chung, Chul Hoon;Oh, Suk Joon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.599-604
    • /
    • 2007
  • Purpose: Blowout fractures of the orbit are common sequelae to blunt facial trauma and now increasing in number due to automobile accidents, violence and industrial disasters. There are some reports of diagnosis and treatment of this fracture, but detailed data provided in overall aspects are very few. We analysed extensive data to provide guide line of blowout fracture patients care. Methods: We retrospectively studied 387 orbital blowout fracture patients who had been followed up at least 3-6 months. Their hospital records were reviewed according to causes, fracture site, operation methods, and follow up results, etc. Results: The ratio of males to females was 7 : 3 and fractures were most often seen in the 20-29 age group. 180(47%) patients had medial orbital wall fractures, 155(40%) patients had floor fractures and 52(13%) patients had a combination of orbital floor and medial wall fractures. The highest associated bone fracture was the nasal bone(37%). The open reduction was done in the 324 patients(83.7%) and insertion materials were used in the 249 patients(77%). Total 45 patients(14%) complained of residual diplopia and 26 patients(8%) kept mild enophthalmos. 24 patients(7%) showed some restriction of extraocular muscle movements. Conclusion: We broadly surveyed the information of blow out fracture patients and believe that this study provides important prognostic information that can be of benefit to both patient and surgeon during preoperative counseling and postoperative analysis of orbital blowout fractures.

Combined Orbital Fractures: Surgical Strategy of Sequential Repair

  • Hur, Su Won;Kim, Sung Eun;Chung, Kyu Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • v.42 no.4
    • /
    • pp.424-430
    • /
    • 2015
  • Background Reconstruction of combined orbital floor and medial wall fractures with a comminuted inferomedial strut (IMS) is challenging and requires careful practice. We present our surgical strategy and postoperative outcomes. Methods We divided 74 patients who underwent the reconstruction of the orbital floor and medial wall concomitantly into a comminuted IMS group (41 patients) and non-comminuted IMS group (33 patients). In the comminuted IMS group, we first reconstructed the floor stably and then the medial wall by using separate implant pieces. In the non-comminuted IMS group, we reconstructed the floor and the medial wall with a single large implant. Results In the follow-up of 6 to 65 months, most patients with diplopia improved in the first-week except one, who eventually improved at 1 year. All patients with an EOM limitation improved during the first month of follow-up. Enophthalmos (displacement, 2 mm) was observed in two patients. The orbit volume measured on the CT scans was statistically significantly restored in both groups. No complications related to the surgery were observed. Conclusions We recommend the reconstruction of orbit walls in the comminuted IMS group by using the following surgical strategy: usage of multiple pieces of rigid implants instead of one large implant, sequential repair first of the floor and then of the medial wall, and a focus on the reconstruction of key areas. Our strategy of step-by-step reconstruction has the benefits of easy repair, less surgical trauma, and minimal stress to the surgeon.

Effective Reconstruction of Extensive Orbital Floor Fractures Using Rapid Prototyping Model (신속 조형 모델을 이용한 안와바닥 골절 정복술)

  • Kim, Hye-Young;Oh, Deuk-Young;Lee, Woo-Sung;Moon, Suk-Ho;Seo, Je-Won;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.633-638
    • /
    • 2010
  • Purpose: Orbital bone is one of the most complex bones in the human body. When the patient has a fracture of the orbital bone, it is difficult for the surgeon to restore the fractured orbital bone to normal anatomic curvature because the orbital bone has complex curvature. We developed a rapid prototyping model based on a mirror image of the patient's 3D-CT (3 dimensional computed tomography) for accurate reduction of the fractured orbital wall. Methods: A total of 7 cases of large orbital wall fracture recieved absorbable plate prefabrication using rapid prototyping model during surgery and had the manufactured plate inserted in the fracture site. Results: There was no significant postoperative complication. One patient had persistent diplopia, but it was resolved completely after 5 weeks. Enophthalmos was improved in all patients. Conclusion: With long term follow-up, this new method of orbital wall reduction proved to be accurate, efficient and cost-effective, and we recommend this method for difficult large orbital wall fracture operations.

Orbital Wall Restoring Surgery in Pure Blowout Fractures

  • Lim, Nam Kyu;Kang, Dong Hee;Oh, Sang Ah;Gu, Ja Hea
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.686-692
    • /
    • 2014
  • Background Restoring orbital volume in large blowout fractures is still a technically challenge to the orbital surgeon. In this study, we restored the orbital wall using the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses, and we compared the surgical outcome to that of a conventional transorbital method. Methods A retrospective review of all patients with pure unilateral blowout fractures between March 2007 and March 2013 was conducted. 150 patients were classified into two groups according to the surgical method: conventional transorbital method (group A, 75 patients, control group), and the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses (group B, 75 patients, experimental group). Each group was subdivided depending on fracture location: group I (inferior wall), group IM (inferomedial wall), and group M (medial wall). The surgical results were assessed by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results In the volumetric analysis, the OVR decreased more by the experimental groups than each corresponding control groups (P<0.05). Upon ophthalmic examination, neither the differences among the groups in the perioperative Hertel scale nor the preoperative and postoperative Hertel scales were statistically significant (P>0.05). Conclusions Our surgical results suggest that orbital volume was more effectively restored by the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses than the conventional method, regardless of the type of fracture.

Transnasal Reduction of Blow Out Fracture with Transconjunctival Approach (경결막 접근법과 비강을 통한 정복술을 이용한 안와골절의 수술)

  • Lee, Won;Kang, Dong Hee;Oh, Sang A;Lee, Sung Whan
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: Many surgical approaches for reconstruction of blow out fracture have been introduced, which include subciliary incision, transconjunctival incision and transcaruncular incision. Recently endoscopic approach has been attempted. This study was intended to show the effectiveness of the approach through transconjunctival incision combined with transnasal reduction in reconstructing blow out fracture to its original position. Methods: Medical recoreds of 43 patients from March 2008 to March 2009 who underwent surgery for orbital fracture were reviewed, retrospectively. All fractures were operated through transconjuctival incision approach combined with transnasal reduction. The average follow-up period was 10.1 months. To evaluate the surgical outcomes of orbital fracture, we performed CT of the facial bone before and after the surgery. In addition, preoperative and postoperative data of enophthalmos, diplopia and the limitation of extraocular motion was assessed with physical examination. Results: Post-operative CT scan of 43 patients assured that the bone fragments of the orbital fractures were restored to their original positions. Although a few patients developed postoperative transient diplopia or impairment of ocular movement, most of the patients recovered during the follow-up period without complication. Conclusion: From this study, we were able to demonstrate the effectiveness of the transnsasal reduction technique combined with the approach through transconjunctival incision. This technique can be considered as very useful means of repairing orbital fracture. It is not only easy to perform but also it can minimize the damage to the orbital bone. Furthermore, it can restore the fracture to its original position as much as possible.

Modified Orbitozygomatic Approach without Orbital Roof Removal for Middle Fossa Lesions

  • Lopez-Elizalde, Ramiro;Robledo-Moreno, Edgar;O'Shea-Cuevas, Gabriel;Matute-Villasenor, Esmeralda;Campero, Alvaro;Godinez-Rubi, Marisol
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.3
    • /
    • pp.407-414
    • /
    • 2018
  • Objective : The purpose of the present study was to describe an OrBitoZygomatic (OBZ) surgical variant that implies the drilling of the orbital roof and lateral wall of the orbit without orbitotomy. Methods : Design : cross-sectional study. Between January 2010 and December 2014, 18 patients with middle fossa lesions underwent the previously mentioned OBZ surgical variant. Gender, age, histopathological diagnosis, complications, and percentage of resection were registered. The detailed surgical technique is described. Results : Of the 18 cases listed in the study, nine were males and nine females. Seventeen cases (94.5%) were diagnosed as primary tumoral lesions, one case (5.5%) presented with metastasis of a carcinoma, and an additional one had a fibrous dysplasia. Age ranged between 27 and 73 years. Early complications were developed in four cases, but all of these were completely resolved. None developed enophthalmos. Conclusion : The present study illustrates a novel surgical OBZ approach that allows for the performance of a simpler and faster procedure with fewer complications, and without increasing surgical time or cerebral manipulation, for reaching lesions of the middle fossa. Thorough knowledge of the anatomy and surgical technique is essential for successful completion of the procedure.