• Title/Summary/Keyword: Enhancement of Heat Transfer

Search Result 446, Processing Time 0.034 seconds

Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes (응축용 특수 전열관의 열전달 특성에 관한 연구)

  • 한규일;박종운;권영철;조동현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF

Heat Transfer Enhancement by Trapezoid Rods in Impinging Jet System (충돌분류계에서 사다리형로드에 의한 열전달증진 효과)

  • 금성민
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.28-33
    • /
    • 2004
  • The objective of the study was to investigate the characteristics of heat transfer and flow in 2-dimensional impinging air jet system, in which trapezoid rods have been set up in front of impinging plate in order to increase heat transfer. Experiments were carried out first using without the rods to establish the baseline heat transfer performance. And this result compared with the experimentation with rods. When rods are installed in front of the impinging plate, the acceleration of the flow and the eddies due to the rods seem to contribute to the heat transfer enhancement. Heat transfer performance was best under the condition of C=1 n and as the pitch is 30 mm. In this case, maximum rate of heat transfer augmentation is about 1.62 times greater compared to that without trapezoid rods.

Effects of Pulsating Flow on the Performance of a Plate Heat Exchanger (맥동유동이 판형 열교환기 성능에 미치는 영향)

  • Gang, B.H.;Kim, D.K.;Park, K.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1479-1484
    • /
    • 2003
  • The heat transfer enhancement by pulsating flow in a plate heat exchanger has been experimentally investigated in this study. The effect of the pulsating flow, such as pulsating frequency and flow rate, on the heat transfer as well as pressure drop in a plate heat exchanger has been studied in detail. Reynolds number in cold side of a plate heat exchanger is varied $100{\sim}530$ while that of hot side is fixed at 620. The pulsating frequency is considered in the range of $5{\sim}30$ Hz. The results of the pulsating flow are also compared with those of steady flow. It is found that the average heat transfer rate as well as pressure drop is increased as flow rate is increased for both steady flow and pulsating flow cases. When pulsating flow is applied to the plate heat exchanger, heat transfer could be substantially increased in particular ranges of pulsating frequency or Strouhal number; $St=0.36{\sim}0.60$ and pressure drop is also increased, compared with those of steady flow.

  • PDF

Thermal Flow Characteristics of Impinging Air Jet by Shape of Turbulence Promoter (난류촉진체 형상에 의한 충돌제트의 열유동 특성)

  • Kum, Sungmin;Jho, Shigie;Yu, Byeonghun;Lee, Seungro
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • In this study, it was experimentally investigated the effect of the clearances distance between the rod and the impinging plate on characteristics of the thermal flow. For the heat transfer enhancement of wall jet region, the right triangle and the square rods were arranged in front of the impinging plate with various clearance distances. As results, the heat transfer enhancement rate of potential core region at H/B=2 was higher than that of transition region at H/B=10. In this experiment range, the maximum heat transfer enhancement rate was about 46 % higher at the square rod with H/B=2 and C=1mm compared with the flat plate. The heat transfer enhancement rate of the right triangle rod was on average about 3 to 8 % higher than that of the square rod, regardless of the clearance.

Enhancement of Heat Transfer by Chaotic Stirring (혼돈적 교반에 의한 열전달 향상)

  • Suh, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.20-28
    • /
    • 1994
  • A numerical study has been performed on enhancement of heat transfer in a forced convection of the modified driven-cavity flow which was previously found by the author to give a regular or chaotic stirring depending on the parameter value. It is found that for the present case wherein heat is transmitted between fluid and the surrounding walls, the chaotic stirring enhances the heat transfer at high Peclet numbers. The optimal condition of the flow modulation for the best heat transfer can be predicted by purely investigating the hydrodynamic facet, i.e. the stirring effect.

  • PDF

Numerical analysis on heat transfer due to buoyancy force of viscoelastic fluid (점탄성 유체의 부력에 의한 열전달 수치해석)

  • Ahn S. T.;Sohn C. H.;Shin S. H.
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.9-16
    • /
    • 1999
  • The present study investigates flow character and heat transfer behaviors of viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. An axially-constant heat flux on bottom wall and peripherally constant temperature boundary condition(H1) was adopted. The Reiner-Rivlin fluid model is used as the normal stress model for the viscoelastic fluid and temperature-dependent viscosity model is adopted. The present results show a signifiant change of the main flow field which causes a large heat transfer enhancement. This phenomena can be explained by the combined effect of buoyancy, temperature-dependent viscosity and viscoelastic property on the flow.

  • PDF

Performance Evaluation of Finned Tube Heat Exchanger with Vortex Generators in a Low Reynolds Number Regime (레이놀즈 수가 낮은 영역에서 와류발생기를 적용한 핀-관 열교환기 성능평가)

  • Kwak Kyung-Min;Song Gil-Dal
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • The present paper reports the method for evaluation of heat-transfer performance of finned tube heat exchangers in a low Reynolds number regime (Re = $160\~800$) and also reports the data of heat transfer and pressure loss taken from a finned tube heat exchanger with/without vortex generators (VGs) installed as a heat-transfer enhancement device. The evaluation is based on the modified single blow method conducted in a specially designed low Reynolds number duct. Three different test core geometries, i.e., fin only, fin-tube without VGs and that with VGs, are studied here. The data of heat transfer and pressure loss taken from the fin only geometry agree well with the empirical correlations, thus validating the present method as used for low Reynolds number regime. The data taken from the finned tube geometries with and without VGs are presented and compared to examine the effect of VGs in the low Reynolds number regime.

Numerical Study on the Heat Transfer Enhancement of Trapezoidal Vortex Generator in a Rectangular Channel (사각채널에서 사다리꼴 와류발생기에 의한 열전달 촉진에 대한 수치해석)

  • Park, T.H.;Lee, S.R.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.852-857
    • /
    • 2018
  • Vortex Generators are used in heat exchanger to enhance the heat transfer of air side. 3-D numerical analysis is performed on heat transfer characteristics of a channel with trapezoidal vortex generator. We investigate the effects of vortex generators with two different inclined angles to flow direction which are forward and backward vortex generators. The thermal hydraulic performance such as Nu and pressure drop, is compared quantitatively. The results show that vortex generator enhances the heat transfer by developing boundary layers and secondary flow in the downstream. The downwash flow region corresponds to the maximum Nu, while the upwash flow region corresponds to Nu minimum. In the view of the heat transfer characteristics, FVG is better than BVG. However, when flow is turbulent as Re increases, the pressure drop for FVG is higher than that for BVG.

Pool Boiling Enhancement of R-123 Using Perforated Plates (다공판을 사용한 R-123 풀비등 열전달 촉진)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.275-281
    • /
    • 2016
  • In this study, we investigate the pool boiling enhancement caused by perforated plates on top of a smooth surface. We conduct tests using R-123 at atmospheric pressure. It was shown that perforated plates significantly enhanced the pool boiling of the smooth surface. The reason may be attributed to the increased bubble contact area between the plates. The results showed that the enhancement ratio was dependent on the heat flux. At high heat flux, the enhancement ratio increased as the porosity increased. However, at low heat flux, the enhancement ratio decreased as the porosity increased. For the present investigation, the optimum configuration had a pore diameter of 2.0 mm, pore pitch of $2.5mm{\times}5.0mm$ or $5.0mm{\times}5.0mm$, and a gap width of 0.5 mm, which yielded heat-transfer coefficients that are close to those of GEWA-T. The optimum porosity for R-123 was significantly larger than that of water or ethanol. The reason for this may be the large liquid-to-vapor density ratio along with the small latent heat of vaporization of R-123. The perforated plates yielded smaller boiling hysteresis compared with that of the smooth surface.

Performance Evaluation in Fin-Tube Heat Exchanger by Tow-In Winglet Pairs (Tow in 와류발생기에 의한 핀-관 열교환기의 성능실험)

  • ;Kahoru Torii
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2003
  • To reduce the air side pressure drop in air-cooled heat exchanger, tow-in type winglet vortex generators are applied. A specially designed multiple-channel test core was used in the experiments for the various geometry of winglet vortex generators. The proposed tow-in type vortex generator gives significant separation delay, reduces form drag, and removes the zone of poor heat transfer from near-wake of the tubes. The results show the significant pressure drop reduction for the tow-in win91e1 vortex generators with the similar enhancement of the heat transfer as other vortex generator applications in heat exchanger. In the range of Reynolds number of 350 to 2100 the pressure drop decrease 8∼15% and 34∼55% for the in-line and staggered tube banks, respectively, compared to those without vortex generators.