• 제목/요약/키워드: Enhanced Geothermal System

검색결과 34건 처리시간 0.027초

Thermo-fluid engineering in deep geothermal energy

  • 김영원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.84.1-84.1
    • /
    • 2015
  • Recent years in particular in Korea see intensive interests in a deep geothermal engineering and its application in different uses as far as from direct uses to power generation sectors, that are achieved by harnessing hot energy sources from the earth. For instance widespread interest has been generated because the geothermal energy is the source that one extracts it for more than 20 hours per day and for about 30 years of an operation of the plant, which enables to give base load as for heating as well as an electric generation. In retrospect, shallow geothermal energy using heat pumps is commonplace in Korea while the deep geothermal is in the early stage of the development. Geothermal energies in view of the way of extracting heat are mainly categorized into several types such as a single well system, a hydrothermal system, an enhanced geothermal system (EGS) etc. In this talk, this speaker focuses on the thermo-fluid engineering of the single well system by introducing the modeling in order to harness hot fluid that is thermally balanced with the fluid of an injection well, which provides a challenge to assess the life time of the well. To avoid the loss of the temperature in producing the hot fluid, a specialized pipe or a borehole heat exchanger has been designed, and its concept is introduced. On the other hand, a binary system or an organic Rankine cycle, which provides the methodology to convert the heat into an electricity, is briefly introduced. Some experimental results of the binary system which has been constructed in our lab will be presented. Lastly as for the future direction, some comments for the industrialization of the deep geothermal energy in this country will be discussed.

  • PDF

EGS 지열발전시스템을 적용한 제주 지열발전소 (Application of Enhanced Geothermal Systems for Jeju geothermal power plant)

  • 이상돈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.573-573
    • /
    • 2009
  • 지열에너지는 지구가 생성될 당시부터 지구 내부에 존재하는 무한한 열에너지로 온실가스 배출이 적으며 태양광이나 풍력 등 다른 신재생 에너지와는 달리 일정한 에너지를 공급할 수 있는 항상성 에너지로 기저부하를 담당할 수 있다. 지열을 이용한 전력 생산은 1904년에 이탈리아 라데렐로에서 처음으로 시작되었으며, 현재까지 화산지대를 중심으로 활발히 이루어지고 있다. 2001년에서 2005년 사이에 전세계 지열발전용량은 약 13% 증가하였으며, 2005년을 기준으로 약 8,933MWe의 지열발전설비가 가동 중이다. 최근 들어 지하 심부까지 시추하여 지열저장소(geothermal reservoir)를 형성하고 이를 통해 지열에너지를 생산하는 새로운 시스템인 EGS(Enhanced Geothermal Systems)가 개발됨에 따라 비화산지대에서도 지열발전소를 건설하려는 움직임이 가속화되고 있다. EGS는 지하 심부의 불투수성 결정질 암반에 존재하는 지열에너지의 경제적인 생산뿐만 아니라 물을 주입하여 생산시키는 순환 방식을 이용하여 지열에너지 획득의 매개 역할을 하는 지열수의 고갈 문제를 해결하였다. 결정질 암반에서의 지열저장소의 형성은 암반 내에 분포하는 불연속면에서 주로 발생하며, 이를 위한 압력 조건은 현지 암반의 응력 분포 특성과 암반 및 불연속면의 물성에 좌우된다. 시추공을 통해 지하 심부의 암반에 수압이 가해지면 물의 주입으로 불연속면의 마찰력이 감소하며, 이로 인해 불연속면에 전단변형이 발생하게 된다. 전단변형은 불연속면을 열린 상태로 유지시켜 지열저장소를 형성하게 된다. 불연속면의 전단 변형시 발생하는 미소 탄성파는 시추공 주변에 설치한 모니터링 장비에서 측정되며, 모니터링 장비에 의해 측정된 미소 탄성파 발생 지점의 클러스터는 지열저장소의 공간적 분포 및 규모를 추정할 수 있는 자료가 된다. 현재 EGS를 이용한 지열발전 프로젝트는 프랑스 슐츠, 스위스 바젤, 호주 하바네로에서 대표적으로 진행 중이다. 슐츠는 현재 1.5MWe의 파일럿 플랜트를 가동 중이며, 하바네로는 파일럿 플랜트 건설 단계를 진행중이다. 스위스 바젤은 지열저장소를 형성시킬 목적으로 수행된 주입시험에서 발생된 문제에 대한 기술의 신뢰성을 확보할 목적으로 잠시 중단된 상태다. 제주도는 신생대에 분출하여 형성된 대표적인 한국의 화산지형으로 지열부존 가능성이 높을 것으로 예상되는 지역이다. 따라서 폐사는 지열에너지 부존 특성을 파악하기 위한 심부 물리 탐사 및 탐사정 시추가 실시될 예정이며 궁극적으로 국내 최초의 상용화된 지열발전소 건설을 목표로 하고 있다.

  • PDF

한국의 지열에너지 부존량 산출 (Assessment of Geothermal Energy Resources of Korea)

  • 박성호;이영민;김종찬;김형찬;구민호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.617-620
    • /
    • 2008
  • 지열에너지는 지구 내부의 깊은 곳에서부터 발생하는 열과 상부 지각에서 방사성 동위원소의 붕괴에 의한 열에 의해 발생한다. 지열에너지는 다른 신재생에너지(수력, 풍력, 태양력, 조력, 바이오 매스등)에 비하여 가동효율이 높고, 지속가능한 재활용 자원으로 경제적 효율성이 높아 전 세계적으로 활용도와 잠재성이 높은 신재생에너지의 하나로 각광 받고 있다. 따라서, 지열에너지의 사용은 화석 연료 사용의 상당부분을 대체할 수 있고, 온실가스의 배출도 줄일 수 있다. 현재 우리나라의 지열에너지 이용은 저온성 지열에너지를 이용한 냉난방에 국한되어 있지만, 앞으로의 지열에너지 이용은 Enhanced Geothermal System(EGS) 을 이용한 지열에너지 개발에 초점이 맞추어질 것이다. 현재의 지열에너지 개발을 용이하게 하고, 또한 미래의 지열에너지 개발에 대비하여 우리나라의 이용가능한 지열에너지 부존량을 파악하기 위해 본 연구를 수행하였다. 연구 수행에는1560개 열물성 자료(밀도, 비열, 열전도도), 353개 지표 지열류량 자료, 180개 열생산율 자료와 54개의 지표온도 자료가 사용되었다. 우리나라의 지표에서부터 1 km 깊이 간격별로 5 km 깊이까지 지열에너지 부존량을 산출한 결과 지표에서 부터 5 km 깊이까지의 추출 가능한 지열에너지의 총 부존량은 $1.01{\times}10^{23}$ J로 산출되었다. 지열에너지 부존량을 Toe(석유환산톤) 로 환산하면 $2.40{\times}10^{12}$ Toe 가 된다. 추출한 지열에너지 자원의 2%를 사용한다고 가정 했을때 약 480억 Toe 이다. 이는 2006년 우리나라 전체 1차 에너지 총 소비량(2.33억 Toe)을 고려 했을때 약 200년 동안 사용할 수 있는 양이다.

  • PDF

R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성 (Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant)

  • 최연성;강희정;김은오
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.14-20
    • /
    • 2017
  • Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

지열 융설시스템을 적용한 포장체에서의 열전도 분석 (The Thermal conductivity analysis on the pavement applying geothermal snow melting system)

  • 이석진;김봉찬;서운종;이승하;이주호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.221-228
    • /
    • 2010
  • A sliding accident on the road have a high percentage by road freezing, especially, it is often appeared at bridges and Tunnel of freezing areas. Thus, the stability of road operations is enhanced by preventing a partial freezing phenomenon. According to the geothermal snow melting system analysis, a pattern of thermal conductivity is found out about pavement materials of concrete and asphalt when it is buried. The thermal conductivity study is essential that be applied the geothermal snow melting system according to heating exchanger pipe laying of lower pavements. The model tests are conducted on low temperature in freezer using the manufactured test model which is equal to pavement materials. And Many variables are discovered from numerical analyzes of the same conditions with model test.

  • PDF

우리나라 EGS 지열발전의 이론적 및 기술적 잠재량 평가 (Estimation of Theoretical and Technical Potentials of Geothermal Power Generation using Enhanced Geothermal System)

  • 송윤호;백승균;김형찬;이태종
    • 자원환경지질
    • /
    • 제44권6호
    • /
    • pp.513-523
    • /
    • 2011
  • 이 연구에서는 최근에 발표되고 국제기구에 의해 공인된 protocol에 따라 인공 지열 저류층 생성 기술(EGS)을 통한 우리나라 지열발전의 잠재량을 평가하였다. 잠재량 추정에 필요한 입력 자료인 암석 밀도, 비열 및 열전도도는 1,516개 암반 시료의 측정값을 이용했으며, 열생산율은 180개 자료, 지열류량은 352개 자료, 그리고 지표면 온도는 54개 자료를 사용하였다. 내륙을 34,742개의 $1'{\times}1'$ 크기 격자로 나누어 3-10 km 깊이 범위에 걸쳐 1 km 깊이 구간별로 온도 분포를 계산하고 이로부터 열에너지 부존량을 계산하였다. 지하 3-10 km 범위의 이론적 잠재량은 6,975 GW로 계산되었고 이는 2010년 우리나라 총 발전용량인 76 GW의 약 92배에 달한다. 기술적 잠재량은 3-6.5 km 깊이, 개발행위가 가능한 지역만을 고려하고 또한 암반으로부터의 열 회수율(0.14)과 발전시설의 온도 특성까지 포함해서 산출되었다. 온도하강요소 $10^{\circ}C$를 고려할 때 총 기술적 잠재량은 19.6 GW로 나타나고 있다. 만약 온도하강요소를 경제적 잠재량에 포함시킬 수 있도록 제외한다면 기술적 잠재량은 56 GW로 늘어난다.

데이터센터 냉방시스템 고효율화를 위한 국내 수열에너지 보급 제도 개선에 관한 연구 (A Study on the Improvement of the Water Source Energy Distribution Regulation for High Efficient Data Center Cooling System in Korea)

  • 조용;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, the current regulation of the water source energy, one of the renewable energy, was analyzed, and the improvement plan for the high efficient data center cooling system was suggested. In the improvement plan, the design and construction guidelines of the water source energy system permit to adopt the cooling and heating system with or without heat pump. In addition, it should also include the system operated in the cooling mode only all year-round. The domestic test standards to consider the water source operating conditions should be developed. Especially, it is highly recommended that the test standards to include the system with forced cooling and free cooling modes related with the enhanced data center cooling system adopting the water source energy.

우리나라 지열발전 pilot plant 프로젝트의 발전량 추정 (Estimating generation capacity of geothermal power generation pilot plant project)

  • 송윤호;이태종;윤운상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.197.1-197.1
    • /
    • 2011
  • 2010년 12월에 착수한 인공 지열 저류층 생성기술(EGS)를 이용한 지열발전 pilot plant 프로젝트에서 계획된 5 km 깊이의 doublet 시스템에서 실현 가능한 발전량 목표를 추정하였다. 지하 5 km 에서의 암반 온도는 경북 포항지역의 평균 지온증가율은 $33^{\circ}C$/km로 하였을 때 지표온도를 감안하면 $180^{\circ}C$로 추정된다. 암반과의 열교환을 통해 생산되는 지열수의 온도를 $160^{\circ}C$, 발전 후 주입수의 온도를 $60^{\circ}C$로 생각할 수 있고, 이때 binary 발전의 열효율은 0.11이 가능하다. 최근의 EGS에서 실현 가능한 생산 유량인 40 kg/sec을 가정한다면 총 발전량은 1.848 MW로 계산되며, 지열수 양수 펌프와 binary 발전의 냉각에너지 소요량을 고려하면 순 발전량 1.5 MW가 가능해진다.

  • PDF

도로주행 안정성 향상을 위한 지열 융설시스템 열전도 분석 (Analysis of Geothermal Melting System Conductivity for Improving Road Safety)

  • 이석진;김봉찬;이승하;서운종;김진한;이주호
    • 한국재난관리표준학회지
    • /
    • 제3권1호
    • /
    • pp.43-50
    • /
    • 2010
  • 도로에서 발생하는 사고 중 도로결빙에 의한 미끄러짐 사고비율이 높으며, 특히 상습 결빙 지역인 교량과 터널 입출부에서 발생 빈도가 높게 나타난다. 이렇게 부분적으로 발생되는 결빙 현상을 방지하여 도로운영의 안정성을 높이고자 한다. 지열 융설의 기초 연구를 통해 일반 도로포장 재료인 콘크리트, 아스팔트 두 종류의 재료에 대한 융설시 열전도 양상을 파악하고자 한다. 지열융설 시스템 적용시 포장체 하부 열교환 파이프 매설에 따른 열전도도 연구가 필요하다. 도로 포장과 동일 재질의 시험체를 제작하여 냉동고에서 저온상태의 모형시험을 수행 하였고, 모형시험과 동일 조건의 수치해석을 통해 보다 다양한 융설에 대한 변수를 파악하였다.

  • PDF

순환식 지하수 수막시스템 그린하우스 난방을 위한 스탠딩컬럼웰 열교환율 산정 (Estimation of Heat Exchange Rate of Standing Column Well for Sustainable Groundwater Curtain for Greenhouse Heating)

  • 심병완;백승균;정성훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.11-23
    • /
    • 2024
  • In order to design a standing column well (SCW) for a sustainable groundwater curtain system for greenhouse heating, we conducted parameter sensitivity tests. These tests simulated the outlet temperature changes of the SCW in a groundwater recirculating greenhouse cultivation system. Our modeling considered ground thermal conductivity and hydrogeological conditions. Specifically, we examined several factors, including SCW length, enhanced thermal conductivity of the ground, and groundwater circulation rate. The simulation results indicated that there was not a significant difference in the heat exchange rate based on the characteristics of enhanced thermal conductivity. However, we anticipate a substantial difference in the case of varying SCW lengths. Therefore, we conclude that the simulation results are primarily influenced by conductive heat exchange values, as the circulating water remains at a constant groundwater level.