DOI QR코드

DOI QR Code

Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant

R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성

  • Received : 2017.10.20
  • Accepted : 2017.11.23
  • Published : 2017.12.01

Abstract

Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

Keywords

References

  1. Ozgener, O., and Hepbasli, A., 2005, A performance analysis of a solar-assisted ground-source heat pump system for greenhouse heating: an experimental study, Vol. 40, pp. 1040-1050. https://doi.org/10.1016/j.buildenv.2004.08.030
  2. Kim, O.J., Kim, D. H., Yoon, S. H., Song, C. H., and Lee, K. H., 2015, Global trends of the technology for low GWP refrigerant, SAREK, Winder Conference, pp. 130-133.
  3. Aikins, K. A., and Choi, J. M., 2012, Current status of the performance of GSHP(ground source heat pump) units in the Republic of Korea, Energy, Vol. 47, pp. 77-82. https://doi.org/10.1016/j.energy.2012.05.048
  4. Tu, X., Liang, X., and Zhuang, R., 2011, Study of R32 refrigerant for residential air-conditioners and heat pumps using the next generation refrigerants, In, IEA Heat Pump Conference.
  5. Koyama, S., Takata, N., and Fukuda, S., 2010, Dropin experiments on heat pump cycle using HFO-1234ze(E) and its mixtures with HFC-32, International Refrigeration and Air Conditioning Conference at Purdue.
  6. Gebbie, J., Jensen, M., and Domanski, P., 2007, Experimental transient performance of a heat pump equipped with a distillation column, International Journal of Refrigeration, Vol. 30, pp. 499-505. https://doi.org/10.1016/j.ijrefrig.2006.08.014
  7. www.kemco.or.kr
  8. www.kraac.or.kr
  9. Korean Standard Association, 2016, Water-to-water geothermal heat pump unit: KS B 8292, Korea Industrial Standards, Seoul, Korea.