• 제목/요약/키워드: Engineering major

검색결과 11,644건 처리시간 0.035초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

『숙천제아도(宿踐諸衙圖)』를 통해 본 조선시대 읍치(邑治)의 공간구조와 관아(官衙) 조경 - 평안도 영유현과 황해도 신천군을 중심으로 - (A Study on the Spatial Structure of Eupchi(邑治) and Landscape Architecture of Provincial Government Office(地方官衙) in the Late Joseon Dynasty through 'Sukchunjeahdo(宿踐諸衙圖)' - Focused on the Youngyuhyun Pyeongan Province and Sincheongun Hwanghae Province -)

  • 신상섭;이승연
    • 헤리티지:역사와 과학
    • /
    • 제49권2호
    • /
    • pp.86-103
    • /
    • 2016
  • 조선후기 문신 한필교(1807~1878년)가 관직을 역임했던 읍치를 대상으로 제작한 "숙천제아도(宿踐諸衙圖)" 화첩의 평안도 영유현과 황해도 신천군 읍치를 분석 자료로 활용하여 실증사료로서의 가치추적, 공간구조 등의 전형성 정립, 관아조경 및 문화경관 특성 도출 등을 시도한 연구결과는 다음과 같다. '풍수형국도' 성격을 겸하며 사방전도묘법으로 그려진 "숙천제아도"의 읍치도는 조선시대 지방고을의 터잡기와 공간구조는 물론 환경설계원칙 등을 파악할 수 있는 사료적 가치를 지닌다. 고을 치소(邑治)는 남북 중심축선에 위계를 설정한 배산임수 체계이며, 전조후침(前朝後寢)의 관아시설, 그리고 3단1묘의 제례처 등 도성에 준한 토지이용과 배치규범을 적용하고 있다. 교통요충지에 자리한 고을 치소는 어귀 장터마당을 결절점으로 안길을 따라 북쪽으로 향하면 관아 문루에 다다르는 노단경이 형성되고, 고갯길 또는 물길을 따라 외부 바깥길로 이어지는 체계를 갖는다. 즉, 동선체계는 바깥길-고갯길-어귀길-장터마당-안길-또는 샛길로 수용력과 위계에 따라 분절되며 3거리 길로 접합되는 양상이다. 지방관아의 토지이용은 3조(三朝)의 개념(외조, 치조, 연조)을 반영한 위계적 구성인데, 동헌의 후원과 객사의 별원을 포함하여 3문3조2원(三門三朝二園)의 공간체계를 보여준다. 고을의 뒷동산 소나무 숲, 명당수인 남천, 안산(案山)에 해당하는 조산(造山), 비보숲 읍수(邑藪) 등 풍수적 경관짜임이 작용되었는데, 겨울철 북서풍 차단과 여름철 상승기류 형성 등 에너지 보존, 색체 항상성, 자연재해 방지와 심리적 안정성 등 쾌적성 조건에 부합되는 환경지속성이 추출된다. 한적한 곳에 자리한 향교는 별도의 원림을 가꾸지 않았으며, 누정은 심신수양, 안분지족, 자연회귀 같은 상징적 가치, 정치적 행사와 윤리관 반영, 유흥상경 등 문화경관 양상이 다양하게 표출되는데, 객사에는 기와를 얹은 와정(瓦亭)이, 동헌과 내아에는 네모꼴 연못을 두고 소박한 모정(茅亭)이 도입되는 차별성을 보여준다. 관아에 지표경관으로 문루가 자리하고, 군사훈련 및 심신수양을 겸한 사정(射亭)이 필수시설로 도입되었다. 아사의 앞뜰은 네모꼴 마당(庭)으로 조경처리를 하지 않은 반면, 정청의 뒤뜰(後園)과 객사의 별원(別園) 등은 장식적으로 가꾸었다. 이러한 관아조경은 공간 성격 및 위계를 반영하되 기능적 지속성(차폐와 방화, 미기후조절 등)과 심리적 건전성, 상징성 등을 복합적으로 고려한 경관미학이라 하겠다. 한편, 소나무, 느티나무, 배나무, 버드나무, 향나무(또는 노송), 연(蓮), 화목(花木) 등이 조경식물로 활용되었는데, 환경심리적 가치가 부가된 배후숲, 조산숲과 비보숲 등과 함께 건전한 문화경관 요소로 자리매김하고 있다. 이러한 분석결과를 일반화 시킬 수 있느냐 하는 문제는 조선시대 읍치의 공간구조 및 환경설계 원칙이 제도적 틀 안에서 정형성으로 작용되고 있어 연구의 한계를 극복할 수 있으리라 판단된다.

중국 전통서원의 수체계와 수경관의 구성적 특성 (A Study on the Compositional Characteristics of Water Systems and Landscapes in Traditional Chinese Seowons)

  • 마서효;노재현
    • 헤리티지:역사와 과학
    • /
    • 제55권3호
    • /
    • pp.74-100
    • /
    • 2022
  • 본 연구는 중국 서원의 특성을 구명하고 이를 바탕으로 한국 서원 고유의 수경관 특성을 준거할 수 있는 자료 확보를 목적으로 시도되었다. 문헌조사와 현장 관찰조사를 바탕으로 악록서원을 비롯한 중국의 대표적인 전통 서원 10개소의 입지와 내·외부의 수체계 그리고 수경관의 연출 특성을 조사 분석한 연구의 결론은 다음과 같다. 중국 서원의 수체계는 내부와 외부 수체계로 이원화되며 보편적으로 외부에 2개, 최다 3개의 수체가 중첩된 양상을 보였다. 외부 수체계에 입각한 서원의 입지유형은 양면환수형 4개소, 환산면수형 3개소 그리고 삼면환수형, 사면환수형, 의산방수형이 각각 1개소 등 총 5개 유형으로 분류됨에 따라, 배산면수형(일명 배산임수형)의 전형을 보이는 한국 서원과 비교할 때, 매우 적극적인 친수성을 보였다. 외부 수체계의 수형(水形)은 곡류형(46.0%), 계류형(36.0%), 광형(廣形)과 부정형(각 9.0%)으로 구분되었으며 수태(水態)는 계(溪, 31.8%), 강(江, 27.3%), 샘과 우물(泉·井, 13.6%), 폭(瀑, 9.1%), 호(湖, 4.5%) 그리고 지(池, 4.5%) 등의 순으로 나타났다. 서원 내부 수체계 상의 수경관은 악록서원에서 7개소, 만송서원에서 4개소 순으로 상대적 수경관의 수가 많았다. 조사대상 10개 서원에서는 확인된 총 27곳의 세부 수경관은 지당(池塘)과 반지(伴池)를 포함하여 총 6개 유형으로 분류됨으로써 한국 서원보다 다양성이 매우 높았다. 주목할 만한 것은 중국 전통 서원의 내부 수경관에는 최소한 반지나 방당(方塘)이 1개소 이상 연출되는 예제적 질서가 잘 드러났다. 특히 한국 서원에서는 보기 어려운 반지는 42.8%를 차지하여 중국 서원의 대표적인 수경관 요소임이 확인되었다. 주희의 「관서유감」 시에 근거한 남계서원의 방당 또한 방형의 반지로 취급한다면 수경관에서 차지하는 반지의 비중은 거의 50%에 육박한다. 지당의 형태는 방형(28%), 자유곡선형과 원형(각 24%), 반월형(20%), 계류형(3.8%)로 구성되었는 바, 이는 방형 일색의 한국 서원과는 매우 다른 특성으로 보인다. 한편 중국 서원의 내부 수경관 관련 조형물은 정(亭)과 교(橋) 11개소(26.8%), 방(坊) 5개소(16.5%), 문(門)과 누(樓) 4개소(1.4%), 재(齋)가 2개소(6.2%) 그리고 헌(軒)·사(祠)·대(臺)·각(閣)이 각 1개소(3.1%) 등 총 10개 유형으로 확인되었으며 서원 내부의 정자는 경관정(景觀亭 27.2%), 비정(碑亭, 18.2%), 연집정(宴集亭, 54.5%) 등 3가지로 유형화되었다. 전반적으로 정자, 반교를 갖는 반지 그리고 패방은 중국 서원 내부 수경관을 지배하는 연계성 높은 주요 구성요소임이 확인되었다.

한반도 자생생물 조사·발굴 연구사업 고찰(2006~2020) (Review of the Korean Indigenous Species Investigation Project (2006-2020) by the National Institute of Biological Resources under the Ministry of Environment, Republic of Korea)

  • 배연재;조기종;민기식;김병직;현진오;이진환;이향범;윤정훈;황정미;염진화
    • 환경생물
    • /
    • 제39권1호
    • /
    • pp.119-135
    • /
    • 2021
  • 생물다양성협약(1992년)과 나고야의정서(2010년)의 체결 이후 우리나라는 한반도의 생물다양성 보전과 생물자원 확보를 위한 자생생물의 조사·발굴 연구에 박차를 가하였다. 이러한 계기로 2007년에 설립된 환경부 소속 국립생물자원관의 주도로 "한반도 자생생물 조사·발굴 연구사업"이 진행되었다. 본 사업은 2006년 이후 현재까지 15년 동안 5단계(1단계 2006~2008년, 2단계 2009~2011년, 3단계 2012~2014년, 4단계 2015~2017년, 5단계 2018~2020년)로 나누어 진행되었다. 연구의 결과, 본 사업의 이전에 29,916종(2006년)이던 한반도 자생생물이 본 사업의 각 단계가 마무리되는 시점에서 누계로 집계하여 볼 때, 1단계 33,253종(2008년), 2단계 38,011종(2011년), 3단계 42,756종(2014년), 4단계 49,027종(2017년), 그리고 5단계 54,428종(2020년)으로 급속히 증가하여 본 사업 기간 동안 한반도 자생생물 기록종이 약 1.8배 증가하였다. 이 통계자료는 이 기간 동안 연평균 2,320종의 한반도 미기록종이 새로이 기록된 것을 보여준다. 또한 전체 발굴종 중에서 총 5,242종의 신종을 기록하는 학술적 큰 성과를 거두었다. 분류군 별로는 총 연구 기간 동안 곤충 4,440종(신종 988종 포함), 무척추동물(곤충 제외) 4,333종(신종 1,492종 포함), 척추동물(어류) 98종(신종 9종 포함), 식물(관속식물과 선태식물) 309종(관속식물 176종, 선태식물 133종, 신종 39종 포함), 조류(algae) 1,916종(신종 178종 포함), 균류와 지의류 1,716종(신종 309종 포함), 그리고 원핵생물 4,812종(신종 2,226종 포함)이 한반도에서 새로이 기록되었다. 생물표본은 각 단계별로 집계하여 볼 때 1단계 247,226점(2008년), 2단계 207,827점(2011년), 3단계 287,133점(2014년), 4단계 244,920점(2017년), 그리고 5단계 144,333점(2020년)이 수집되어 연평균 75,429점, 총 1,131,439점의 생물표본이 채집되었다. 그중에서 곤충 281,054점, 곤충 이외의 무척추동물 194,667점, 척추동물(어류) 40,100점, 식물 378,251점, 조류(algae) 140,490점, 균류 61,695점, 그리고 원핵생물 35,182점이 채집되었다. 본 사업에 참여한 각 단계별 연구원/보조연구원(주로 대학원생)의 수는 1단계 597/268명, 2단계 522/191명, 3단계 939/292명, 4단계 575/852명, 그리고 5단계 601/1,097명으로 전체년도의 참여연구자는 연평균 395명, 총 연인원 약 5,000명이 참여하여 전국의 거의 모든 분류학자와 분류학 전공의 대학원생이 참여하였다. 본 사업 기간 동안 전문학술지 논문 3,488편(국내학술지 논문 2,320편, SCI급 국제학술지 논문 1,168편 포함)이 출판되었다. 본 사업 기간 중 자생생물 조사·발굴 사업 및 생물표본 확보 사업에 투입된 예산은 총 833억원(연평균 55억원)이다. 본 사업은 국가 주도의 대형 연구 프로젝트로서 전국의 거의 모든 분류학자가 참여하고 대규모 예산이 투입되어 단기간에 이루어 낸 한국식 압축성장의 한 성공 사례로 볼 수 있다. 본 사업의 종발굴 성과는 최근의 생물분류 체계로 분류되어 국가생물종목록으로 만들어졌으며, 전문가와 학생 및 일반 시민에게 제공되고 있다(https://species.nibr.go.kr/index.do). 본 사업에서 파생된 기재문, DNA 염기 서열, 서식처, 분포, 생태, 이미지, 멀티미디어 등 각 종의 정보는 디지털화되어 생물의 계통, 진화 연구 등 학문적 발전에 기여하였고, 기후변화에 따른 지표종의 변화 같은 생물분포 모니터링 사업과 바이오산업의 생물소재를 탐색하는 기반이 되었다. 본 사업을 통하여 젊은 분류인력(주로 대학원생)의 양성을 지원할 수 있었던 것은 본 사업이 가져온 가장 의미 있는 성과라고 할 수 있다. 과거 15년간 숨 가쁘게 달려온 본 사업은 아직 진행 중이다. 그동안 발굴된 종들에 대한 이명(synonym)과 오동정 등을 바로잡아 학문적인 완성도를 높이고, 한반도에 존재하리라 예상되는 약 10만 종의 자생생물 중에서 남겨진 5만 종에 대한 조사·발굴 연구가 지속되어야 한다.