• 제목/요약/키워드: Engineering Test Station

검색결과 342건 처리시간 0.023초

Mission Operation Capability Verification Test for Low Earth Orbit(LEO) Satellite by Utilizing Interface Environment between LEO Satellite and Ground Station (저궤도 위성과 지상국간 접속 환경을 활용한 임무수행능력 지상 검증 시험)

  • Lee, Sang-Rok;Koo, In-Hoi;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.142-149
    • /
    • 2014
  • After launch of Low Earth Orbit(LEO) satellite, Initial Activation Checkout(IAC) and Calibration and Validation(Cal & Val) procedure are performed prior to enter normal operation phase. During normal operation phase, most of the time is allocated for mission operation except following up measures to anomaly and orbit maintenance. Since mission operation capability is key indicator for success of LEO satellite program and consistent with promotion purpose of LEO satellite program, reliability should be ensured by conducting through test. In order to ensure reliability by examining the role of LEO satellite and ground station during ground test phase, realistic test scenario that is similar to actual operation conditions should be created, and test that aims to verify full mission cycle should be performed by transmitting created command and receiving image and telemetry data. This paper describes the test design and result. Consideration items for test design are described in detail and result of designed test items are summarized.

A Result Analysis on Field Test for Localization Development of Axle Counter System (Axle Counter System 국산화 개발을 위한 현장시험 결과분석)

  • Ko, Joon-Young;Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권9호
    • /
    • pp.6214-6220
    • /
    • 2015
  • A track circuit has used stably more than 100 years for detecting train position, but solution of track circuit sort circuit incapacity due to a rust is necessary for side line in station yard, coast line and level crossing for conventional line in rural line. Domestically, Axle Counter System(ACS) has partially used for Hot Box System for high speed line and turnout for CBTC system. In contrast, most of countries has used ACS not only trunk line but also rural line and its application has increased for metro, electric car and industrial railway. In this paper, we has verified the operating status of ACS which installed with existing track circuit through log analsis to implement pilot application in mail track and turnout in station yard. And interface test with interlocking system has conducted at Obong shunting yard, as well as Cheongju station and has analyzed test result. Based on a test result, we made fail safe design, manufacturing skill and established system requirement specification for the smooth operation and maintenance.

Indoor and Outdoor $NO_2$ Concentration at Subway Station and Personal $NO_2$ Exposure of Subway Station Workers (지하철역사의 이산화질소 농도와 역무원의 이산화질소 개인폭로량)

  • 손부순;장봉기;박종안;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • 제15권4호
    • /
    • pp.134-141
    • /
    • 2000
  • The person' spending time in underground s[aces within indoor environment show a tendency to increase every year, but in Korea, levels and sources of pollutant in underground spaces have not been well-characterized. Therefore, as part or a larger indoor environmental study, conducted at subway station in Seoul, nitrogen dioxide was measured using passive samplers in 16 subway stations, 2 tunnels and 70 workers of subway station. The mean concentrations of nitrogen dioxide in subway stations were $27.87{\pm}7.15$ ppb at station office, $35.76{\pm}8.35$ ppb at platform, $52.60{\pm}13.04$ ppb at outdoor, respectively, and the Indoor/Outdoor ratio were 0.49~0.93. The mean concentrations of nitrogen dioxide in tunnels were $44.91{\pm}4.67$ ppb in Chunggye-Nowon tunnel with a single track, $42.55{\pm}3.33$ ppb in Mokkol-Taenung tunnel with double track, respectively, and as a result of t-test, a single track levels were higher than double track levels(p<0.05). The mean personal exposure of the subject of station workers was $29.40{\pm}9.75$ ppb.

  • PDF

Optimizing Simulation of Wireless Networks Location for WiBRO Based on Wave Prediction Model (전파 예측 모델에 의한 와이브로 무선망 위치 선정의 최적화 시뮬레이션)

  • Roh, Su-Sung;Lee, Chil-Gee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제19권5호
    • /
    • pp.587-596
    • /
    • 2008
  • For Wireless internet service in Metropolitan area, optimum location selection for base station and cell planning are critical process in determining service coverage by accurate prediction of Wave Propagation Characteristics. Due to different kinds of characteristics in service area such as lay of land, natural feature and material, height and width of artificially made building, it has a great impact on the transmission and distance recovery of wireless network service. Therefore, these facts may cause substantial barriers in predicting & analyzing the expected level of service quality and providing it to subscribers. In this thesis, we have simulated the process to improve quality and coverage of the service by adjusting the location of Base station and the antenna angle that influence the service after the basic location of base station is selected according to the wave prediction model. Based on this simulations test, we have demonstrated the results in which subscribers would get higher quality of wireless internet service along with bigger coverage and the improved quality in the same service coverage area through optimization process of base station.

The study on the BTEX Concentration of Soil in Gas Station (국내 주유소 토양의 BTEX 오염에 관한 연구)

  • Shin, Joung-Nam;Roh, Sung-Hyeuk;Jung, Sang-Rak;Oh, Gil-Rok;Kim, Mi-Kyoung;Yook, Woon-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • 제19권6호
    • /
    • pp.18-23
    • /
    • 2014
  • The BTEX contamination of soil around gas station in Korea was investigated in 53 gas stations in 2013 by official test method on soil pollution. Each gas station was divided into oil tank area, line area, and surrounding area. The concentration of BTEX in 1066 sites of 53 gas stations was N.D.~ 3437.36 mg/kg. The order of average concentration for area was as follows: line area ($20.91{\pm}144.79mg/kg$) > tank area ($15.11{\pm}110.08mg/kg$) > surrounding area ($10.79{\pm}111.40mg/kg$). It was the number of sampling site exceeding regulatory levels at surrounding area the most at all. The average concentration of xylene was the highest, while that of ethylbenzene was the lowest.

Dissolved Oxygen Trend in Sapgyo Stream Watershed (삽교천유역의 용존산소 추세)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • 제46권6호
    • /
    • pp.667-681
    • /
    • 2013
  • In this study, monthly and seasonal dissolved oxygen trends of 19 water quality measurement stations in Sapgyo stream watershed were analyzed using monthly dissolved oxygen (DO) data measured for 16 years (1995~2010). Mann-Kendall trend test and Sen's slope estimator were carried out for trend analysis. Furthermore, Sapgyo stream watershed was divided into four different sections (Sapgyo stream, Muhan stream, Gykgyo stream, and Sapgyo lake) and chi-square test of homogeneity for DO trend was carried out for four different sections. The study results indicated that most of water quality measurement stations showed increasing or non-significant trend of DO on a monthly and seasonal basis. The chi-square test of homogeneity for each water quality measurement station showed the statistical homogeneity in seasonal DO trend; however, the test results showed the statistical non-homogeneity in monthly DO trend for the stations located in the reservoir. Overall, the dissolved oxygen trend in each water quality measurement station showed different patterns depending on the location of each station and season.

Displacement Measuring Lab. Test of Reinforced-Soil Retaining Wall Block using 3D Digital Photogrammetry Image (수치사진영상을 이용한 보강토옹벽블록의 변위계측 실내시험)

  • Han, Jung-Geun;Jeong, Young-Woong;Hong, Ki-Kwon;Cho, Sam-Deok;Kim, Young-Seok;Bae, Sang-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • 제5권3호
    • /
    • pp.45-52
    • /
    • 2006
  • The collapsed cases are more and more increasing at the large scaled structures because of increasing of the risk due to natural disasters. The measuring instrument such as inclinometer, total station on reinforced-soil retaining wall has been used that displacement, settlement for stability assessment, maintenance and management of it. But because these has gotten many instability measuring factors for stability analysis of RRW, new system needs to complement disadvantage of existing system. In this study, we considered a application of Visual Monitoring System (VMS) to measure a displacement in face of wall through Lab. test about block assembly of segmental retaining wall during load test.

  • PDF

Construction of Network RTK Testbed Using Reference Stations of NGII (국토지리정보원 기준국 사용 Network RTK 테스트베드 구축)

  • Bu-Gyeom Kim;Changdon Kee
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제13권1호
    • /
    • pp.103-110
    • /
    • 2024
  • In this paper, a test bed for real-time network Real-Time Kinematic (RTK) research was constructed using reference stations of the NGII. A group of candidate station networks was derived, including three stations in Seoul. The group consisted of four stations with a distance of less than 100 km between them. Among several candidates, a network composed of stations with short distances between them and demonstrating good data quality for all reference stations was selected as the test bed. After collecting real-time data in Radio Technical Committee for Maritime services (RTCM) format from the selected stations and conducting a noise analysis on measurements, mm-level carrier phase measurement noise was confirmed. Afterwards, the user set the reference station inside the test bed and analyzed the network RTK positioning performance of the MAC method using the GPS L1 frequency as post-processing. From the result of the analysis it was confirmed that the residual error for all users was within 10 cm after applying the correction. Additionally, after determining integer ambiguities through Least-squares AMBiguity Decorrelation Adjustment (LAMBDA), it was confirmed that the fix rate was 100%, and all ambiguities were resolved as true values.

Study on Cooling of Hydrogen Gas for the Pre-Cooler in the Hydrogen Refueling Station (수소충전소용 프리쿨러를 위한 수소가스 냉각에 관한 연구)

  • LEE, KYUNG-HAN;KOO, KYUNG-MO;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제30권3호
    • /
    • pp.237-242
    • /
    • 2019
  • In the hydrogen refueling station (HRS), it is need the pre-cooling system (PCS) to limit the inside temperature ($85^{\circ}C$) of the onboard thank (700 bar) and to charge the hydrogen at short time (within 3 minutes) to fuel cell electric vehicle (FCEV). From those safety reasons, the temperature of hydrogen gas must be controled $-33^{\circ}C$ to $-40^{\circ}C$ in PCS. The cooling test of the gaseous ($N_2$, He, $H_2$) was carried out using heat exchanger (pre-cooler) by indirect cooling and direct cooling method. It was confirmed that the temperature of hydrogen gas had below $-40^{\circ}C$ at below $-75^{\circ}C$ of chiller temperature in direct cooling.

Design of RF Supporting Unit for COMS RF Compatibility Test (COMS RF호환성 시험을 위한 RF지원 장비의 설계 및 제작)

  • Park, Durk-Jong;Park, Chun-Woo;Ahn, Sang-Il
    • Aerospace Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.176-186
    • /
    • 2008
  • As determined single coaxial cable for the interface between satellite and ground station in COMS RF compatibility test, RF supporting unit was required to allow signals in different frequency-band to be exchanged in the single coaxial cable. In addition, the path loss between satellite and ground station in normal operation should be simulated through two RF supporting units connected to the ends of single coaxial cable. As an effort to design RF supporting unit, level diagram was firstly conducted on the basis of measured data for each element. From the level diagram, it was found that single coaxial cable connected with two RF supporting units properly represented the path loss between satellite and ground station After RF supporting unit was integrated on aluminum plate, it was tested that input signal level at each test cap linked with MODCS and TC&R was tunable within the required dynamic range. RF supporting unit, now completely integrated, will be applied in the upcoming COMS RF compatibility test.

  • PDF