• Title/Summary/Keyword: Engine Oil

Search Result 870, Processing Time 0.028 seconds

Economic Optimization Study for a $125,000m^3$ Class LNG Carrier

  • Lee, Kyu-Yeul;Lee, Dong-Kon;Jung, Ho-Hyun;Lee, Chul-Hee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.4
    • /
    • pp.1-9
    • /
    • 1984
  • This study is concerned with the economic aspects of $125,000m^3$ class LNG carriers with different propulsion plant such as conventional steam turbine and slow speed diesel engine with reliquefaction plant. The ship's speed and L/B ratio were optimized with criterion of required freight rate(RFR) by using the PROCAL computer program package. In order to investigate the effect of fuel oil price, round trip distance and boil-off rate on the RFR and the optimum speed, sensitivity analysis were also performed.

  • PDF

Conceptual Design of the Fuel Injection Valve Tester for ME-LGI Marine Engine by Using System Engineering (ME-LGI 선박엔진용 연료분사밸브 테스터 개발을 위한 시스템 엔지니어링 기반 개념 설계)

  • Noh, Hyonjeong;Kang, Kwangu;Bae, Jaeil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.681-688
    • /
    • 2018
  • As environmental regulations have been strengthened and high fuel efficiency has been in demand in recent years, the number of ships using natural gas as a fuel is increasing. The demand for ships using LPG or methanol, which are emerging as eco-friendly vessel fuels, is also increasing. In this perspective, ME-LGI engines using LPG or methanol as a fuel have attracted considerable attention. Ships equipped with an ME-LGI engine are required to check the reliability of the fuel injection valve during shipping. This means that the development of a fuel injection valve tester is essential for the commercialization of ME-LGI engine. This study conducted the conceptual design of a fuel injection valve tester for ME-LGI engines using a system engineering process in the order of requirements analysis, functional analysis, and design synthesis. In the requirement analysis stage, the operating process of fuel injection valve was analyzed, and the necessity of checking the sealing oil leakage was then derived. In the functional analysis stage, the functions and flow of them were defined at each functional level. In the design synthesis stage, the equipment for each function was set and the process block diagram based on it was derived. In addition, preliminary risk analysis was performed as a part of system analysis and control, and safety measures were added to the conceptual design. This study is expected to be a good reference material for the concept design of other systems in the future because it shows the application process of a system engineering process to the conceptual design in detail.

Fire Examples Study of Intake and Exhaust System, Alternator Tuning and Inflow of Inflammables on Exhaust Part in a Car (자동차 흡배기장치, 발전기 튜닝 및 배기측 인화성 물질 유입에 관련된 화재사례 연구)

  • Lee, Il Kwon;Kook, Chang Ho;Suh, Moon Won;You, Chang Bae;Youm, Kwang Wook;Lim, Chun Moo;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.47-51
    • /
    • 2014
  • This paper is to analyze and study the fire examples in respect of intake and exhaust, alternator tuning and inflow of inflammables on exhaust part in a car. In the first example, the driver diverted the intake and exhaust system for tuning of a car. Stopping a car to rest for moment, the flammable styrofoam scrap go into exhaust pipe that installed with exhaust manifold newly. It certified the fact that catched fire gradually, furthermore enlarged the fire by leaking fuel. In the second example, the driver enlarged the generator performance to divert the audio system in side room., it knew the fact that the electric wiring connected with generator gave the cause of outbreak a fire by overheating. In the third example, the serviceman replaced the engine oil using funnel-shaped, he put the a bottle of plastic pat onto engine cover carelessly. Consequentially, it found the fire occurrence in the engine room. Therefore, the driver never divert the intake and exhaust and generator construction of a car abnormally. Also, repairing and inspecting a car, the serviceman have a care to not occur the fire by inflammables.

Survey on the Regular Maintenance of Agricultural Machinery (농업기계 정기점검정비 실태조사)

  • Kang, J.W;Lee, W.Y.;Lee, S.B.;Lee, J.H.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.3 no.1
    • /
    • pp.142-157
    • /
    • 2001
  • This study was conducted to get the basic information for promoting farm machinery productivity by surveying the regular maintenance and repair status of major farm machinery such as power tiller, farm tractor, rice transplanter and combine harvester. The survey was carried out through 9 provinces including Cheju province by direct visiting farmers with prepared questionnaire. The results of this study can be summarized as follows : 1. The average farming carrier of the surveyed farmers was 25.3 years, and 21-30 years of farming carrier showed the highest portion as 40.7%. The average carrier of using farm machinery was 9.4 years, and that was 14.9 years for power tiller, 8.3 years for farm tractor, 9.0 years for rice transplanter, 7.9 years for combine harvester, 7.5 years for mini tiller, 9.7 years for power sprayer, and 8.2 years for binder etc. 2. The regular maintenance for farm machinery was conducted mainly at repair shop (49.5%) or dealer agency (12.0%) as 61.5%, and 34.9% of farmers conducted the regular maintenance by themselves at their house. 3. The reasons for not-fully recognizing operation manual and insufficient before-, during-, after-maintenance of farm machinery were insufficient time for them (45.8%), troublesome (22.9%), unknown maintenance method (16.3%), unknown the necessity for maintenance (12.4%), and others (2.6%) in order. 4. For the annual exchange of engine oil, 3.2 times is necessary but actually 1.7 times was exchanged for power tiller, 4.3 times is necessary but actually 1.9 times was exchanged for farm tractor, 2.7 times is necessary but actually 1.7 times was exchanged for rice transplanter, 2.2 times is necessary but actually 2.3 times was exchanged combine harvester. 5. For the annual cleanness or exchange of fuel filter, 3.2 times is necessary but actually 1.1 times was done for power tiller, 4.3 times is necessary but actually 1.6 times was done for farm tractor, 2.7 times is necessary but actually 1.7 times was done for rice transplanter, 1.9 times is necessary but actually 0.8 times was done for combine harvester. 6. For the annual cleanness or exchange of air filter, 3.2 times is necessary but actually 1.4 times was done for power tiller, 4.2 times is necessary but actually 2.4 times was done for farm tractor, 2.6 times is necessary but actually 1.6 times was done for rice transplanter, 3.9 times is necessary but actually 7.0 times was done for combine harvester. 7. For the experience of breakdown related to maintenance, 5.3% of farmers experienced breakdown due to the insufficient exchange of engine oil, 7.7% of farmers experienced breakdown due to the insufficient cleanness or exchange of fuel filter, and 2.9% of farmers experienced breakdown due to the insufficient cleanness or exchange of air filter. 8. Most farmers (76.1%) recognized the necessity for agricultural machinery training or education, and most farmers preferred about one week for the training period, simple or ease maintenance for the training level, agricultural technical center or agricultural machinery manufacturer for the training agency. 9. Complete recognition of operation manual and sufficient before-, during-, and after-maintenance for farm machinery can minimize the breakdown as well as conduct suitable period farming, enlarge the endurance, prevent the safety accidents, and promote productivity of farm machinery. Therefore, these can be accomplished by the thorough training or education for agricultural machinery.

Feasibility Study of Fuel Property for Fuel Processing Design on Ship and Warship (연료유 공정설계를 통한 선박 및 함정의 기본품질 적용 가능성 연구)

  • Hwang, Gwang-Tak;Kim, Do-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Environmental regulations, which are discussed through the International Maritime Organization, focus on two aspects: the economic supply of fuel oil and, ultimately, securing next-generation energy sources. At present, there are limitations in relation to the basic quality of fuel oil and the direct relation through basic quality when applied to ships and traps in relation to environmental regulations, and the standard for the basic quality of fuel oil is generally used. There are many cases where the composition is very complicated, and the interpretation and analysis of basic quality deviate from the range of the basic standard. In other words, it is difficult to classify and apply the problem when analyzing it in connection with fuel quality and ship operations. In this paper are various factors for the basic quality of fuel oil, and a proposed possibility for the scope of the standard.

A Study on the Optimization of Heat Flux in Engine Room of Auxiliary Power Unit for Self-Propelled Artillery (자주포용 보조동력장치 엔진룸의 열유동 최적화에 관한 연구)

  • Noh, Sang Wan;Park, Young Min;Kim, Sung Hoon;Lee, Jae Dong;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.629-635
    • /
    • 2019
  • In this study, we analyzed the effect of FAN and oil cooler application on APU. MIL-STD-810 was applied to the atmospheric environment and radiation dose in order to perform thermal flow analysis. The heat flow was analyzed for the case in which the inlet / outlet fan was applied (Case 1), the case in which the inlet fan and the oil cooler were applied (Case 2), and the case in which the inlet / outlet fan and the oil cooler were applied (Case 3). As a result, it was confirmed that the cylinder head temperature of Case 3 was 21.4 times lower than that of Case 1 and 8.0 times lower than that of Case 2. Experiments were conducted under the same ambient conditions in order to examine the validity of the results. The numerical values and experimental results showed a difference of less than 7%. Through this, we were able to confirm that the APU heat flow optimization model satisfies the design conditions. The results of this study are expected to be used as basic data for optimizing heat flow of APU.

Study of Behavior Characteristics of Impinging Spray of Emulsified Fuel (에멀젼연료 충돌분무의 거동특성에 관한 연구)

  • Yeom, Jeong Kuk;Kim, Hak Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.909-916
    • /
    • 2015
  • In this study, to investigate the effect of spray behavior characteristics, we induce the mixing ratio of emulsified fuel using impinging spray. We formulate the emulsified fuel by mixing diesel and hydrogen peroxide($H_2O_2$). We set the temperature of the heating plate to $150^{\circ}C$, $200^{\circ}C$, and $250^{\circ}C$, and set the injection pressures to 400, 600, 800, and 1000bar. The surfactants for the emulsified fuel mixture, which were mixed span80 and tween80 was mixed as 9:1, were fixed to 3% of the total volume of the emulsified fuel. We set the mixing ratio of $H_2O_2$ in the emulsified fuel as emulsified fuel(EF)0, EF2, EF12, and EF22. Further, we visualize the evaporation impinging spray using the Schlieren method. Based on the results of this study, we found that a higher temperature and injection pressure of the heating plate impingement led to the active diffusion of the fuel vapor, which promoted emulsified fuel evaporation. When the emulsified fuel is utilized in an actual engine, because of the temperature-drop effect of the combustion chamber, which is due to the evaporation of $H_2O_2$ in fuel and faster mixture formation is expected to decrease the engine emissions.

The ETCS Convergence Terminal for Eco-driving and Vehicle Diagnostics (에코-드라이빙과 차량 진단 겸용 ETCS 융합 단말기)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.29-34
    • /
    • 2012
  • Nowadays, the problem of ETCS terminal in becoming popular gradually is that there is no services except for ETC. Therefore, we need new system that provide many type of additional services at one-terminal. In this paper, we study the additory function of ETCS terminal to afford many type of the vehicle administration beside collection and provider of traffic information. We descrived the method of Eco-driving function beside to save fuel signing instant and mean fuel-efficiency, measurement of section fuel-efficiency on OLED and then brings out the best driving habit in people and to prevent dangerous at the wheel as diagnosing engine oil, cooling water, fan belt, the point of changing consumables, diagnoses to an overheated engine, charges on generator through ECU. The multi-services terminal consist of the vehicle diagnosis module base on OBD-II and ETCS terminal.

A Study on the Fire Risk of Black Box Wiring in Motor Vehicle (자동차의 블랙박스 와이어링 화재 위험성에 관한 연구)

  • Kang, Sin-Dong;Kim, Ju-Hee;Choi, Jun-Pyo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • According to the National Fire Data System (NFDS), more than 5,000 vehicle fires have occurred every year for the last 10 years. Vehicle fires are primarily caused by mechanical (breaking system and engine), electrical (wiring and battery), and chemical (oil and fuel gas leakage) problems. The electrical factor has increased with the installation of driver convenience equipment. For example, today, the black box is widely used to provide video data recording of motor vehicle accidents. The black box consists of a front camera, rear camera, and wires. The black box wires are directly connected to the junction box or fuse box from the start battery that operates to provide normal on power supplying for engine stop. It is extremely dangerous when the wires short circuit due to insulation aging, mechanical and electrical stress, etc. In this study, the black box wiring fire risk have been analyzed and investigated when the steady state and abnormal operations, and under the following conditions: wiring arrangements with a high temperature condition, insulation aging, poor contact, and short circuits. The results showed that black box wiring short circuits had a higher fire risk than the other fire hazard elements. To prevent fire hazards caused by black box wiring, the black boxes must be installed by qualified service personnel. Do not modify the wiring, remove the fuse and secure the wiring using cable ties or insulation tape.

A Study on a Comparison of Sky View Factors and a Correlation with Air Temperature in the City (하늘시계지수 비교 및 도시기온 상관성 연구: 강남 선정릉지역을 중심으로)

  • Yi, Chaeyeon;Shin, Yire;An, Seung Man
    • Atmosphere
    • /
    • v.27 no.4
    • /
    • pp.483-498
    • /
    • 2017
  • Sky view factor can quantify the influence of complex obstructions. This study aims to evaluate the best available SVF method that represents an urban thermal condition with land cover in complex city of Korea and also to quantify a correlation between SVF and mean air temperature; the results are as follows. First, three SVF methods comparison result shows that urban thermal study should consider forest canopy induced effects because the forest canopy test (on/off) on SVF reveals significant difference range (0.8, between maximum value and minimum value) in comparison with the range (0.1~0.3) of SVFs (Fisheye, SOLWEIG and 3DPC) difference. The significance is bigger as a forest cover proportion become larger. Second, R-square between SVF methods and urban local mean air temperature seems more reliable at night than a day. And as the value of SVF increased, it showed a positive slope in summer day and a negative slope in winter night. In the SVF calculation method, Fisheye SVF, which is the observed value, is close to the 3DPC SVF, but the grid-based SWG SVF is higher in correlation with the temperature. However, both urban climate monitoring and model/analysis study need more development because of the different between SVF and mean air temperature correlation results in the summer night period, which imply other major factors such as cooling air by the forest canopy, warming air by anthropogenic heat emitted from fuel oil combustion and so forth.