• 제목/요약/키워드: Energy-saving device

검색결과 198건 처리시간 0.02초

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

유기 패시베이션 박막이 P3HT:PC61BM 활성층을 갖는 고분자 태양전지의 특성에 미치는 영향 (Effects of Organic Passivation Films on Properties of Polymer Solar Cells with P3HT:PC61BM Active Layers)

  • 이상희;박병민;조양근;장호정;정재진;피재호
    • 마이크로전자및패키징학회지
    • /
    • 제21권4호
    • /
    • pp.105-110
    • /
    • 2014
  • 재생에너지 광소자로서 스마트 농장 등의 에너지원으로서 고분자 태양전지의 응용이 기대되며 향후 상업화를 위해 효율과 신뢰성 개선이 요구된다. 본 연구에서는 유기 패시베이션 박막을 가지는 헤테로정션 고분자태 전지를 제작하고, 패시베이션 박막이 고분자 태양전지의 특성에 미치는 영향을 조사하였다. 사용된 패시베이션 유기재료로는 폴리비닐알코올과 이크롬산 암모늄을 혼합하여 용해한 후 스핀코팅방법으로 P3HT:$PC_{61}BM$/LiF/Al 기판위에 코팅하여 소자를 제작하였다. 제작된 소자구조는 glass/ITO/PEDOT:PSS/P3HT:$PC_{61}BM$/LiF/Al/passivation layer 이며, 140시간 공기 중에 노출 후 전기적 특성을 측정, 비교한 결과, 패시베이션 처리된 고분자 태양전지가 패시베이션 박막 처리되지 않은 소자에 비해 보다 우수한 전기적 특성을 보여주었다. 즉, 패시베이션 처리된 소자의 전력변환효율은 제작직후 3.0%에서 140시간 노출 후 1.3%로 감소한 반면 패시베이션 처리되지 않은 소자의 경우는 동일한 노출조건에서 3.5%에서 0.1%로 급격한 특성저하를 나타내었다.

Parametric study of propeller boss cap fins for container ships

  • Lim, Sang-Seop;Kim, Tae-Won;Lee, Dong-Myung;Kang, Chung-Gil;Kim, Soo-Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.187-205
    • /
    • 2014
  • The global price of oil, which is both finite and limited in quantity, has been rising steadily because of the increasing requirements for energy in both developing and developed countries. Furthermore, regulations have been strengthened across all industries to address global warming. Many studies of hull resistance, propulsion and operation of ships have been performed to reduce fuel consumption and emissions. This study examined the design parameters of the propeller boss cap fin (PBCF) and hub cap for 6,000TEU container ships to improve the propulsion efficiency. The design parameters of PBCF have been selected based on the geometrical shape. Computational fluid dynamics (CFD) analysis with a propeller open water (POW) test was performed to check the validity of CFD analysis. The design of experiment (DOE) case was selected as a full factorial design, and the experiment was analyzed by POW and CFD analysis. Analysis of variance (ANOVA) was performed to determine the correlation among design parameters. Four design alternatives of PBCF were selected from the DOE. The shape of a propeller hub cap was selected as a divergent shape, and the divergent angle was determined by the DOE. Four design alternatives of PBCF were attached to the divergent hub cap, and the POW was estimated by CFD. As a result, the divergent hub cap with PBCF has a negative effect on the POW, which is induced by an increase in torque coefficient. A POW test and cavitation test were performed with a divergent hub cap with PBCF to verify the CFD result. The POW test result showed that the open water efficiency was increased approximately 2% with a divergent hub cap compared to a normal cap. The POW test result was similar to the CFD result, and the divergent hub cap with the PBCF models showed lower open water efficiency. This was attributed to an increase in the torque coefficient just like the CFD results. A cavitation test was performed using the 2 models selected. The test result showed that the hub vortex is increased downstream of the propeller.

동절기 수박 접목묘의 안정적 생산을 위한 나노탄소섬유적외선 램프의 난방효과에 대한 적정 설치간격 (Proper Installation Distance for Heating Effect of Nano-Carbon Fiber Infrared Heating Lamp for Stable Production of Watermelon Grafted Seedlings in Winter Season)

  • 김혜민;정현우;황희성;황승재
    • 생물환경조절학회지
    • /
    • 제31권1호
    • /
    • pp.8-13
    • /
    • 2022
  • 본 연구는 동절기 공정육묘장의 수박 플러그 묘 생산 시, 난방 에너지 절감에 유리한 난방장치인 나노탄소섬유 적외선 난방등의 효율적인 사용을 위한 적정 전력과 설치 간격을 구명하기 위해 수행되었다. 유리온실 내 소형 베드 6개를 플라스틱 필름으로 구획을 나누었으며, 100cm 높이에 700W와 900W 난방등을 설치하였다. 난방등은 설치 간격을 각각 중앙 1개(Control), 60cm 간격(2개), 40cm 간격(3개)으로 설치하였다. 나노탄소섬유 적외선 난방등을 점등한 후 대조구를 제외한 모든 처리에서 설정한 야간 기온(20℃)을 유지하였다. 엽온은 난방등 설치 간격이 좁을수록 빨리 상승하는 경향을 보였다. 나노탄소섬유 적외선 난방등을 사용함에 따른 처리구간 수박 접목묘의 생육에는 뚜렷한 차이가 없었으나, 엽장과 엽폭은 700W 난방등에서 설치 간격이 짧을수록 길어지는 경향을 보였으며, 700W 난방등을 40cm 간격으로 설치하였을 때 묘의 충실도가 높은 값을 나타내는 것을 확인할 수 있었다. 따라서 야간 기온 유지와 묘의 충실도를 고려하였을 때, 700W 난방등을 40cm 간격으로 설치하는 것이 수박 접목묘를 생산하는데 경제성을 고려하여 효율적인 나노탄소섬유 적외선 난방등의 전력과 설치 간격으로 판단된다.

계층 구조에 기반을 둔 스마트 홈 시스템를 위한 스마트 센서 프레임워크의 설계 (A Design of Smart Sensor Framework for Smart Home System Bsed on Layered Architecture)

  • 정원호;김유빈
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.49-59
    • /
    • 2017
  • 스마트 센싱은 사물인터넷과 관련된 다양한 응용에 있어 핵심적인 역할을 하고 있으며, 그 중요성은 인공지능의 발전과 더불어 점점 증가하고 있다. 그러므로 스마트 센서의 중요성은 아무리 강조해도 지나치지 않다고 할 수 있을 것이다. 그러나 스마트 센서 관련 대부분의 연구는 특정 응용 목적, 예를 들면 보안, 에너지 절약, 감시 등에 집중되고 있으며, 미래에 필요할 다양한 유형의 스마트 센서를 효율적으로 구성하는 방법에 관한 연구는 드믄 실정이다. 본 논문에서는 스마트 센서의 효율적 구성을 위한 계층구조를 가진 컴포넌트 기반의 스마트 센서 프레임워크가 제안되고, 스마트 홈으로의 응용이 설계, 구현된다. 제안된 방법은 가까운 미래에 등장할 다양한 유형의 스마트 센서를, 제안된 소프트웨어 프레임워크 상에서 필요한 컴포넌트의 설계 및 개발을 통해 구성 가능하다는 것을 보여주고 있다. 또한 계층 구조를 가지고 있으므로 내부 혹은 외부 계층의 삽입을 통해 스마트 센서의 구성을 확대시킬 수도 있으며, 특히 외부 장치 계층과의 연결을 통해 사물인터넷 응용 서비스의 설계 시, 내부 혹은 외부 모듈별 독립적인 설계가 가능하다는 장점을 가진다. 제안된 방법을 사용하여 소규모 스마트 홈 시스템이 설계 구현되었으며, 외부의 서버와 연결되어 다수의 스마트 홈을 수용, 관리할 수 있는 홈 클라우드까지 설계 구현되었다. 각 계층의 컴포넌트들을 개발, 추가함으로써, 스마트 카, 스마트 빌딩, 스마트 팩토리 등, 그 응용의 폭을 효율적으로 확대할 수 있을 것이다.

폐쇄형 식물공장내 태양광 파이버를 이용한 상추 재배효과 (Effects of Lettuce Cultivation Using Optical Fiber in Closed Plant Factory)

  • 이상규;이재수;원진호
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.105-109
    • /
    • 2020
  • 본 연구는 태양광 기반으로 인공광 병렬 광공급 시스템을 개발하고 상추 재배효과를 구명하기 위하여 수행하였다. 태양광 기반으로 인공광원을 공급하는 장치는 광원 공급부, 전원공급부, 시스템 계측 및 제어부로 구성하였다. 광원공급부는 태양광 전송장치(광파이버)와 LED 램프(인공광)로 구성하였고, 태양광 전송장치는 광 전송률이 우수한 석영재질의 광섬유(Optical fiber)로 제작되었으며, 인공광은 LED 중 White 램프를 사용하였다. 전원 공급부는 누전 차단기, SMPS, LED 제어기 및 릴레이로 구성하였다. 시스템계측 및 제어부는 터치스크린과 지그비(ZigBee) 통신모듈, 광량센서로 구성하였다. 구성한 장치의 성능시험 결과 광량센서로 측정된 강도가 200μmol·m-2·s-1 이하가 되면 자동적으로 LED 램프가 작동되어 보광하는 것을 확인하였다. 또한 본 장치를 활용하여 상추를 재배한 결과, 엽장, 뿌리길이, 엽록소 함량 및 지하부 생체중이 LED 처리보다 큰 것으로 나타났다. 따라서본 장치는 화석연료 고갈 등으로 전기 사용에 제한이 올때 폐쇄형 식물공장 같은 시설에서 작물을 재배할 수 있을 것으로 판단된다.

실시간 소전력 감시 및 원격제어용 지능형 콘센트 개발 (Development of Intelligent Outlets for Real-Time Small Power Monitoring and Remote Control)

  • 홍경진
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.169-174
    • /
    • 2023
  • 현재 가정이나 사무실 및 공장 등 전력 수요가 증가하면서 전체 전력 사용량도 증가하고 있다. 전력사용의 증가는 에너지 절약에 대한 의식 변화가 나타나면서 대기전력에 대한 관심도도 높아졌다. 가정용 및 사무용 기기는 대기상태에서도 전력을 소모하고 있다. 이에 대기전력의 저감에 대한 필요성이 매우 커지고 있으며 대기전력 1W이하를 목표로 하고 있다. 지능형 콘센트는 근거리 무선망을 이용하여 홈네트워크에 연결하고 콘센트에 연결된 램프나 가전기기의 대기전력을 차단하거나 절감시키는 것이다. 본 연구에서는 근거리 무선망(Zigbee)를 이용하여 콘센트에 연결된 조명램프나 가전기기에서 사용하는 전기의 사용량을 원격으로 모니터링 하고 대기전력을 차단할 수 있는 모니터링 시스템과 지능형 콘센트을 개발하고자 한다. 또한, 개발하는 지능형 콘센트와 모니터링 시스템은 휴대용 장치(리모콘)를 이용하여 사용자가 손쉽게 대기전력을 차단할 수 있다.지능형 콘센트는 대기전력을 저감시킬 뿐만 아니라 화재 방재 시스템에도 응용 가능할 것이다. 대기하는 전력을 차단 하는 장치는 지능형 콘센트와 대기전력 차단 스위치를 포함하므로 누전과 화재를 방지할 것이다.

충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석 (Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region)

  • 남상운;김영식
    • 농업과학연구
    • /
    • 제36권1호
    • /
    • pp.73-85
    • /
    • 2009
  • 충남지역 토마토 재배온실의 구조적 안정성 확보와 체계적 환경관리를 위한 기초자료를 제공할 목적으로 구조 및 환경조절설비 실태를 조사 분석하였으며 그 결과를 요약하면 다음과 같다. 조사대상 충남지역의 토마토 재배온실은 호당 평균면적 0.45ha, 플라스틱 단동온실의 형태가 대부분이며 10년 이상 시설을 사용하고 있는 농가가 많고, 설치방향은 단 연동 구분 없이 대부분 남북동으로 설치되어 있으며 토양재배가 수경재배에 비해 훨씬 많다. 온실의 폭은 7~8m(평균 7.6m), 길이는 80~100m(평균 89.7m)인 농가가 대부분이었으며, 단동온실의 평균 높이는 측고 1.6m, 동고 3.2m, 연동온실의 평균높이는 측고 2.9m, 동고 4.8m로 농촌진흥청의 보급형 온실에 비하여는 약간 높게 나타나고 있지만 토마토 재배에 적합한 환경관리를 위해서는 온실의 측고를 좀 더 높여야 할 것으로 사료된다. 단동온실의 서까래 규격은 양호하나 설치간격이 대체로 넓고, 도리의 설치 개수가 부족한 것으로 나타났다. 연동온실의 경우 서까래, 도리, 중방의 규격과 설치간격은 대체로 양호하나 기둥의 설치간격이 대체로 넓은 편이어서 구조적인 안전성 검토가 필요할 것으로 사료된다. 단동 서까래 매설부위 및 연동 기둥의 기초부위는 침하나 인발에 충분히 저항 할 수 있을 것으로 판단된다. 피복재는 대부분 PE필름을 사용하고 에너지 절감을 위해 내부에 고정터널을 설치하는 농가가 많으며 내피도 대부분 PE필름을 사용하고 있다. 단동온실에서는 보온커튼을 사용하는 농가가 많지 않고, 연동에서는 대부분 부직포 또는 알루미늄스크린 등의 다층 보온커튼을 사용하고 있다. 관수장치는 점적호스를 가장 많이 사용하고 다음으로 분수호스를 사용하고 있으며, 관수제어는 수동이 가장 많고 다음으로 타이머를 이용하고 있다. 토양수분 계측에 의한 자동제어는 7.5%에 불과해 관수자동화의 필요성이 높은 것으로 판단된다. 난방은 대부분 온풍 난방기를 이용하고 있으며 적정 난방기 용량을 확보하고 있지 못한 농가도 많아 저온기 생육적온 유지에 어려움이 있을 것으로 판단된다. 난방비는 10a당 평균 6백만 원 정도가 연간 소요되는 것으로 조사되어 난방비 절감 대책이 절실한 것으로 사료된다. 대부분 권취식 천측창을 설치하고 있으나 단동의 경우 천창을 설치한 온실은 17.5%에 불과하며, 환기창 개폐장치는 대부분 자동으로 이루어져 있다. 강제 환기팬이나 공기 유동팬을 설치한 온실은 25.8%에 불과하며 설치대수가 매우 부족하고 정확한 설치기준이 마련되어 있지 못하다. 별도의 구조물에 토마토 유인줄을 설치하지 않고 중방이나 서까래에 설치하는 농가가 많아 구조물에 미치는 작물하중의 영향을 검토할 필요가 있는 것으로 판단된다. 기타 탄산가스 시비, 광환경 제어, 지중가온이나 방충망설치, 하절기 온실 냉방 등 고도의 환경조절을 실시하는 농가는 거의 없는 것으로 나타났다.

  • PDF