• 제목/요약/키워드: Energy system design

검색결과 4,920건 처리시간 0.034초

체계적인 헬리콥터 내추락성 설계개념 연구 (A Study on the Systematic Crashworthiness Design Concept)

  • 황정선;정재권;현영오
    • 항공우주시스템공학회지
    • /
    • 제7권2호
    • /
    • pp.35-41
    • /
    • 2013
  • Crashworthiness design concept in the helicopter development is still under evolutionary stage. Survivability in the event of a crash was remarkably improved and this fact can be recognized by the analysis results on the AH-64 Apache and UH-60 Black Hawk crash accidents. Those two models are the first ones in which the crashworthiness design concept was applied with a full-scale requirement. Here we need to notice that under-design of the system results in unexpected injuries and deaths while over-design of the crashworthy elements result in unnecessary weight and costs. If landing gear system would be verified to have enough energy absorption capability in the specified vertical velocity interval, then design requirements of the airframe, fuel system and seats could be modified positively. In this paper, the right and systematic crashworthiness design concept is reviewed on the assumption that design requirements of some crashworthy elements could be partially tailored.

반송동력과 건물층고 저감형 공조시스템 개발 (Development of HVAC System to Lower the Conveyance Energy and Building Height)

  • 김정엽;신현준
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

Prototype Microgrid의 동특성 모의에 관한 연구 (A Study on Simulation of Dynamic Characteristics in Prototype Microgrid)

  • 최은식;최흥관;전진홍;안종보
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2157-2164
    • /
    • 2010
  • Microgrid is generally defined as cluster of small distributed generators, energy storages and loads. Through monitoring and coordinated control, microgrid can provide various benefits such as reduction of energy cost, peak shaving and power quality improvement. In design stage of microgrid, system dynamic simulation is necessary for optimizing of sizing and siting of DER(distributed energy resources). As number of the system components increases, simulation time will be longer. This problem can restrict optimal design. So we used simplified modeling on energy sources and average switching model on power converters to reduce simulation time. The effectiveness of this method is verified by applying to prototype microgrid system, which is consist of photovoltaic, wind power, diesel engine generators, battery energy storage system and loads installed in laboratory. Simulation by Matlab/Simulink and measurements on prototype microgrid show that the proposed method can reduce simulation time not sacrificing dynamic characteristics.

Development of Human Factors Engineering Program Plan (HFEPP) for MMIS Design of KNGR

  • Cha, Kyung-Ho;Park, Geun-Ok;Seo, Sang-Moon;Cheon, Se-Woo;Bong S. Sim
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.355-360
    • /
    • 1996
  • Human factors principles and evaluation methodologies are applied to design the MMIS of the KNGR. Human factors issues identified from the previous MMIS design of a nuclear power plant are considered in the development of the HFEPP. To manage human factors issues in the MMIS design of the KNGR, a conceptual Human Factors Issue Tracking System (HFITS) is also considered.

  • PDF

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

소규모 지역냉난방 시스템 최적설계 시뮬레이션 (The Simulation Approach for the Optimal Design of Small Scale District Heating and Cooling System)

  • 임용훈;박화춘;조수;장철용;정모
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.147-154
    • /
    • 2008
  • A simulation program is developed for the optimal design of small scale district heating and cooling system. Main features for the simulation program are the reliability and the easiness for the optimal design of the DHC(District Heating and Cooling) systems. In order for implementing those features, the operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types, of which the corresponding district consist, such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features and the overall procedure of the simulation are described in brief in this paper. The results of the simulation for several test cases will be presented in subsequent study.

  • PDF

주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석 (An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type)

  • 최경석;정영선;강재식;이승언;정영용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

Optimal Design of Air Compressor-Driving Quadratic Linear Actuator in Fuel Cell BOP System Using Orthogonal Arrays Matrix

  • Kim, Jae-Hee;Kim, Jin-Ho;Jang, Chang-Hwan
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.120-124
    • /
    • 2011
  • The design of an air compressor-driving quadratic linear actuator in a fuel cell BOP system is studied using orthogonal techniques. The approach utilizes an orthogonal array for design of 'experiments', i.e. the scheme for numerical simulations using a finite element method. Eco-friendly energy is increasingly important due to the depletion of fossil fuels and environmental pollution. Among the new energy sources, fuel cell is spotlighted as renewable energy because it produces few dusts. The air compressor performance is directly related to the efficiency of the fuel cell BOP system has high power consumption. In this paper, an optimized technique using an orthogonal matrix is applied to the design problem to improve the performance of quadratic linear actuator.

Development of An Integrated Test Facility (ITF) for the Advanced Man Machine Interface Evaluation

  • Oh, In-Seok;Cha, Kyung-Ho;Lee, Hyun-Chul;Sim, Bong-Sick
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.117-122
    • /
    • 1995
  • An Integrated Test Facility(ITF) is a human factors experimental environment to evaluate an advanced man machine interface(MMI) design. The ITF includes a human machine simulator(HMS) comprised of a nuclear power plant function simulator, man-machine interface, experiment control station for the experiment control and design, human behavioural data measurement system, and data analysis and experiment evaluation supporting system(DAEXESS). The most important features of ITF is to secure the flexibility and expandibility of Man Machine Interlace(MMI) design to change easily the environment of experiments to accomplish the experiment's objects In this paper, we describe a development scope and characteristics of the ITF such as, hardware and software development scope and characteristics, system thermohydraulic modelling characteristics, and experiment station characteristics for the experiment variables design and control, to be used as an experiment environment for the evaluation of VDU-based control room.

  • PDF