• 제목/요약/키워드: Energy saving rate

검색결과 326건 처리시간 0.027초

개별환경제어시스템의 열 및 유동 해석 (Air Flow and Heat Transfer Analysis of Personal Environment Module System)

  • 조은준;서태범;박영철
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.252-261
    • /
    • 2001
  • Room air flow and temperature distribution was numerically investigated where a PAC(personal air conditioning) system was installed. The calculated results were compared with those from experiments. The effects of the important operation parameters such as the air flow rate, velocity, and temperature at the diffuser on the thermal performance of the system were studied. The possibility of energy saving using the PAC system was verified from the results, It was shown that the warm air from the diffuser could not spread over the whole task area if the inlet temperature was too high.

  • PDF

직결식 변속펌프의 운전 방안에 대한 연구 (A Study on the Operating Characteristics of Variable Speed Pump for In-Line Booster Pumping Station)

  • 박종문;최성일;노형운;서상호;김상균
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.191-196
    • /
    • 2001
  • In the systems with largely pipe head loss, variable speed pumps are generally used because substantial energy saving can be expected from such systems by controlling pump speed and also they offer simpler maintenance and operational ease even in conditions where abrupt changes In flow rate and head can occur. The invertor or the fluid coupling system are mainly adopted to control the rotating speed. In this paper, operating conditions at Migum pressing pump station(5 stage), where the fluid coupling system was the first installed for KOWACO, are investigated and analysed so that information thus gained can be usefully employed in the efficient operation of variable speed pump in new installations of in-line booster pumping station.

  • PDF

산소부화와 선회수에 따른 평면화염버너의 로 내 연소특성 (Combustion characteristics inside the furnace with a flat flame burner by oxygen enriched and swirled air)

  • 곽지현;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.177-184
    • /
    • 2001
  • Combustion using oxygen enriched air is an energy saving technology that can increase thermal efficiency by the improvement of burning rate and high temperature flame. But information about it is not so enough yet. Flame figure, temperature distribution and emission concentration were measured with oxygen enriched concentration and swirl number in a turbulent diffusion flame to investigate the combustion characteristics. The results showed that flame figure became different as long as oxygen enriched concentration varied and that concentration of NO increased suddenly around $O_2$ 60%.

  • PDF

냉장고 기계실 유로 최적화를 통한 소비 전력 저감 (Optimization of refrigerator machine room for energy saving)

  • 김영국;한병윤;김재열;김태훈;이연원;김남식
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.101-106
    • /
    • 2002
  • In the Refrigeration and air conditioning industrial circles, refrigerator is demands a high degree of efficiency due to the Environmental Preservation Law. Many researchers are working on factors to improve the efficiency of the refrigerator In this paper, a study of the factors on the decrease of electric power consumption, several experiments are performed to improve the fluid flow in the refrigerator machine room. As a results, average temperatures of compressor and condenser are reduced 3.1$^{\circ}C$, 2.$0^{\circ}C$. The consuming electric power rate is reduced 0.7kWh/month.

  • PDF

공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수 (The optimal parameters in series-series counterflow chillers system within air conditioning)

  • 웬민푸;뷔옥훙;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

스위칭 엑티비티를 최소화한 저전력 DCT 아키텍쳐 구현 (Low-Power DCT Architecture by Minimizing Switching Activity)

  • 김산;박종수;이용석
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2005년도 춘계학술발표대회
    • /
    • pp.863-866
    • /
    • 2005
  • Low-power design is one of the most important challenges encountered in maximizing battery life in portable devices as well as saving energy during system operation. In this paper we propose a low-power DCT (Discrete Cosine Transform) architecture using a modified Computation Sharing Multiplication (CSHM). The overall rate of power consume is reduced during DCT: the proposed architecture does not perform arithmetic operations on unnecessary bits during the Computation Sharing Multiplication calculations. Experimental results show that it is possible to reduce power dissipation up to about $7{\sim}8%$ without compromising the final DCT results. The proposed lowpower DCT architecture can be applied to consumer electronics as well as portable multimedia systems requiring high throughput and low-power.

  • PDF

산소부화공기가 난류 확산 평면화염의 연소에 미치는 영향 (Effect of Oxygen Enriched Air on the Combustion of a Turbulent Diffusion Flat Flame)

  • 곽지현;전충환;장영준
    • 한국연소학회지
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2003
  • Combustion using oxygen enriched air is an energy saving technology that can increase thermal efficiency by the improvement of burning rate and by the high temperature flame. Flame figures, OH radical intensities, temperature distributions and emission concentrations were measured according to oxygen enriched concentration and swirl number in a turbulent diffusion flat flame. It appeared that flame figure became flat and NO concentration decreased with increase of swirl number, and that the flame temperature increased high with increase of oxygen enriched concentration. In particular, it was most significant between oxygen concentration $40{\sim}60%$.

  • PDF

축열식 저 NOx 연소기의 배가스 재순환이 연소특성에 미치는 영향 (The effect of flue-gas recirculation on combustion characteristics of regenerative low NOx burner)

  • 강민욱;윤영빈;동상근
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.97-104
    • /
    • 2002
  • The conventional regenerative system has a high thermal efficiency as well as energy saving using the high preheated combustion air. in spite of these advantages, it can not avoid high nitric oxide emissions. Recently, flameless combustion has received much attention to solve these problems. In this research, numerical analysis is performed for flow-combustion phenomena in the self regenerative burner. In this analysis we used Fluent 6.0 code. the that is developed for commercial use, Methane gas is used as a fuel and two-step reaction model for methane and Zeldovich mechanism for NO generation are used. the velocity of the preheated combustion air is used as a parameter and we analyze the characteristics of flow-field, temperature distributions and NO emissions. Due to the increased recirculation rate, the maximum temperature of flame is significantly increased and NOx emissions is reduced

  • PDF

열회수장치에 의한 열교환 성능 분석(농업시설) (Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct)

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

전송률에 기반한 IEEE 802.l1b 에너지 모델 (An Energy Model for IEEE 802.11b based on Transmission Rate)

  • 김태현;차호정
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2004년도 가을 학술발표논문집 Vol.31 No.2 (3)
    • /
    • pp.124-126
    • /
    • 2004
  • 본 논문은 CAM(Constant Awake Mode), 및 PSM(Power Saving Mode)을 지원하는 IEEE 802.l1b[1] Infrastructure 환경에서 전송 프로토콜이 이동기기의 WNIC(Wireless Network Interface Card) 에너지 소비에 미치는 영향을 분석하고 단위 시간 동안 전송되는 데이터 양에 기반한 IEEE 802.l1b WNIC 에너지 모델을 제안한다. 제안하는 에너지 모델은 IEEE 802.l1b 환경에서 CAM 및 PSM 모드를 사용할때, 실제 측정한 값을 기반으로 설계되었다. 제안된 에너지 모델은 실험을 통하여 정확성을 검증하고, IEEE 802.l1b를 기반으로한 저전력 통신 관련 연구에서 시뮬레이션 시 사용 가능한 에너지 모델임을 밝힌다.

  • PDF