• Title/Summary/Keyword: Energy plus

Search Result 463, Processing Time 0.036 seconds

ADVANCED DVI+

  • Kwon, Tae-Soon;Lee, S.T.;Euh, D.J.;Chu, I.C.;Youn, Y.J.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.727-734
    • /
    • 2012
  • A new advanced safety feature of DVI+ (Direct Vessel Injection Plus) for the APR+ (Advanced Power Reactor Plus), to mitigate the ECC (Emergency Core Cooling) bypass fraction and to prevent switching an ECC outlet to a break flow inlet during a DVI line break, is presented for an advanced DVI system. In the current DVI system, the ECC water injected into the downcomer is easily shifted to the broken cold leg by a high steam cross flow which comes from the intact cold legs during the late reflood phase of a LBLOCA (Large Break Loss Of Coolant Accident)For the new DVI+ system, an ECBD (Emergency Core Barrel Duct) is installed on the outside of a core barrel cylinder. The ECBD has a gap (From the core barrel wall to the ECBD inner wall to the radial direction) of 3/25~7/25 of the downcomer annulus gap. The DVI nozzle and the ECBD are only connected by the ECC water jet, which is called a hydrodynamic water bridge, during the ECC injection period. Otherwise these two components are disconnected from each other without any pipes inside the downcomer. The ECBD is an ECC downward isolation flow sub-channel which protects the ECC water from the high speed steam crossflow in the downcomer annulus during a LOCA event. The injected ECC water flows downward into the lower downcomer through the ECBD without a strong entrainment to a steam cross flow. The outer downcomer annulus of the ECBD is the major steam flow zone coming from the intact cold leg during a LBLOCA. During a DVI line break, the separated DVI nozzle and ECBD have the effect of preventing the level of the cooling water from being lowered in the downcomer due to an inlet-outlet reverse phenomenon at the lowest position of the outlet of the ECBD.

Effect of Glucose on Listeria monocytogenes Survival under Sequential Sublethal Stresses of Gamma Irradiation and NaCl

  • Yoon, Yo-Han;Kim, Gyeong-Yeol;Nam, Min-Ji;Shim, Won-Bo;Seo, Eun-Kyoung;Kim, Jae-Hun;Lee, Ju-Woon;Byun, Myung-Woo;Chung, Duck-Hwa
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.162-166
    • /
    • 2009
  • This study evaluated glucose effect on Listeria monocytogenes survival under gamma irradiation and NaCl stress. L. monocytogenes in phosphate buffered saline (PBS) plus glucose (0-4%) was treated with gamma irradiation (0-0.5 kGy), and the samples were then exposed to NaCl (0-9%) in tryptic soy agar plus 0.6% yeast extract. $D_{10}$ and $t_{3D}$ values were determined, and a model for prediction of $D_{10}$ values was developed. Cell counts of L. monocytogenes reduced as irradiation dose increased, and L. monocytogenes in PBS (no glucose) was more sensitive to irradiation and NaCl compared to those in PBS (2 or 4% glucose). $D_{10}$ values were 0.07-0.1, 0.12-0.16, and 0.13-0.15 kGy for 0, 2, and 4% glucose, respectively. The $t_{3D}$ values were 0.22-0.3 (0% glucose), 0.35-0.48 (2% glucose), and 0.40-0.44 (4% glucose). A model performance was acceptable. These results indicate that glucose in foods would increase the resistance of L. monocytogenes to gamma irradiation and NaCl stress.

The Study on Synthesis Gas Characteristics Following Different Injection Condition of Oxidizing Agent Through Simulation of Underground Coal Gasification (지중 석탄가스화 공정 시뮬레이션을 통한 산화제 주입조건에 따른 합성가스 특성에 대한 연구)

  • Jang, Dong-Ha;Yoon, Sang-Phil;Kim, Hyung-Taek;Kim, Jeong-Gyoo;Cho, Won-Jun;Ju, Woo-Sung;Lee, Jin-Wook;Lee, Chan
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.28-36
    • /
    • 2013
  • The underground coal which is buried in the ground will have a lot of attention to overcome energy crisis as an energy resources standpoint. Many studies of underground coal gasification have been also conducted because of its advantage which does not require mining. In this study, the simulation of underground coal gasification process was carried out with Aspen Plus. This study was executed by Rock Mountain 1 Underground Coal Gasification project in the United States in the late 1980s as a reference. Sensitivity analysis proceeded to investigate synthesis gas characteristics following different injection condition of oxidizing agent. The underground coal gasification model has been implemented. That is divided into drying, pyrolysis, char gasification and the simulation results was confirmed by the production gas flow, yield of synthesis gas and amount of gasified carbon from results of the actual experimental data.

Evaluation of Electric Power Consumption during Seawater Desalination (해수담수 공정의 전력비 평가기준에 관한 연구)

  • Shim, Kyu Dae;Kim, Chang Ryong;Choung, Joon Yeon;Kim, Dong Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.485-492
    • /
    • 2021
  • This study focused on safety aspects surrounding energy consumption in the seawater desalination process in the Daesan Industrial Complex located on the West Sea coast. The safety index for energy consumption was evaluated under different salinities and temperatures of the incoming seawater. Temperature and salinity input data for the 1997-2018 period were obtained from the Marine Environment Information System, and the power required for reverse osmosis (RO) was applied to the program as per the data provided by the RO membrane manufacturer (Q-Plus v3.0). Notably, reasonable energy consumption guidelines were proposed during the design of the desalination facilities; in this regard, the desalination process required approximately 2.10-2.90 kWh/m3 electrical power. Moreover, the energy safety based on 95 % was estimated to be 2.80 kWh/m3 when the desalination facility was operated.

A Study on System Optimization of Texaco Gasifer Based IGCC(I) (텍사코 가스화기 적용 석탄가스화 복합발전소 계통 최적화 연구(I))

  • 조상기;김종진;서석빈;이윤경
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.49-53
    • /
    • 1999
  • 석탄가스화복합발전시스템 설계기술 개발 연구의 일환으로 상용 공정설계 프로그램인 Aspen Plus, Tsweet, Gatecycle을 이용하여 계통구성 최적화 연구를 수행하였다. 석탄은 대동탄(Tatung Coal)을 사용하였으며 그 성상은 <표 1>과 같다. 대동탄은 국내화력발전설비에서 사용되고 있는 모든 석탄을 대상으로 석탄의 특성에 따른 가스화 반응특성을 분석한 결과, 석탄가스화에 가장 적합한 성상으로 나타난 바 있다.(중략)

  • PDF

Energy metabolism and whole-exome sequencing-based analysis of Sasang constitution: a pilot study

  • Kim, Hyoung Kyu;Lee, Heetak;So, Ji Ho;Jeong, Seung Hun;Seo, Dae Yun;Kim, Jong-Yeol;Kim, Sanguk;Han, Jin
    • Integrative Medicine Research
    • /
    • v.6 no.2
    • /
    • pp.165-178
    • /
    • 2017
  • Background: Traditional Korean Sasang constitutional (SC) medicine categorizes individuals into four constitutional types [Tae-eum (TE), So-eum (SE), Tae-yang (TY), or So-yang (SY)] based on biological and physiological characteristics. As these characteristics are closely related to the bioenergetics of the human body, we assessed the correlation between SC type and energy metabolism features. Methods: Forty healthy, young ($22.3{\pm}1.4$ years) males volunteered to participate in this study. Participants answered an SC questionnaire, and their face shape, voice tone, and body shape were assessed using an SC analysis tool. Thirty-one participants (10 TE, 10 SE, 3 TY, and 8 SY) were selected for further analysis. Collected blood samples were subjected to blood composition analysis, mitochondrial function analysis, and whole-exome sequencing. Results: The SY type showed significantly lower total cholesterol and high-density lipoprotein cholesterol levels than the SE type. Cellular and mitochondrial Adenosine triphosphate (ATP) levels were similar across types. All types showed similar basal mitochondrial oxygen consumption rates, whereas the TE type showed a significantly lower ATP-linked oxygen consumption rate than the other types. Whole-exome sequencing identified several genes variants that were exclusively detected in particular SC types, including 19 for SE, seven for SY, 11 for TE, and six for TY. Conclusion: SC type-specific differences in mitochondrial function and gene mutations were detected in a small group of healthy, young Korean males. These results are expected to greatly improve the accurate screening and utilization of SC medicine.

Field Tests of DC 1500 V Stationary Energy Storage System

  • Lee, Hanmin;Kim, Gildong;Lee, Changmu;Joung, Euijin
    • International Journal of Railway
    • /
    • v.5 no.3
    • /
    • pp.124-128
    • /
    • 2012
  • The ESS(energy storage system, here after) for a DC 1500V was developed in 2009. A ESS was installed on the track of Daejeon HRT in 2010. The advantage of the ESS is that it can save the energy and plus stable the catenary voltage. This paper presents the energy saved by the ESS in Daedong substation. When the ESS is on/off, the field tests are performed.

ANN-Based VRF (variable refrigerant flow) system control (인공신경망 기반 VRF 시스템 제어)

  • Moon, Jin Woo
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.9-16
    • /
    • 2019
  • This study aimed at developing control algorithms for operating a variable refrigerant flow (VRF) heating and cooling system with optimal system parameter set-points. Two artificial neural network (ANN) models, which were respectively designed to predict the heating energy cost and cooling energy amount for upcoming next control cycle, was developed and embedded into the control algorithms. Performance of the algorithms were tested using the computer simulation programs - EnergyPlus, BCVTB, MATLAB in an incorporative manner. The results revealed that the proposed control algorithms remarkably saved the heating energy cost by as much as 7.93% and cooling energy consumption by as much as 28.44%, compared to a conventional control strategy. These findings support that the ANN-based predictive control algorithms showed potential for cost- and energy-effectiveness of VRF heating and cooling systems.

A Study on the Perfomance Analysis of Low Energy Cooling Systems in Office building (사무소건물의 에너지절약형 냉방시스템 성능분석에 관한 연구)

  • Park, Chang-Bong;Rhee, Eon-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.89-94
    • /
    • 2010
  • A large portion of the energy cost of a building is cooling and heating to maintain a comfortable indoor environment. Air conditioning is now one of the important parts in the building design, as increase in energy consumption and pollutant emission in energy conversion process. In this study, elements that affects the energy consumption of model building are identified and the perfomance analysis of the alternative a Low Energy Cooling Systems considering characteristics of model building and energy saving performance is analyzed. In this study, elements that affect the energy consumption of office building are identified and energy saving performance of the alternative air conditioning system is analyzed. As a result, applied to earn and suggest basic data for energy saving measures. In this study, EnergyPlus simulation program was used to evaluate the energy load when alternative Low Energy Cooling Systems are applied to the model building. The reliability of simulation program is verified by comparing actual energy load from operation data of building management office and predicted energy load using simulation program. For Low Energy Cooling System application which considers the purpose and characteristics of the building, reasonable and energy-saving air conditioning method obtained by analyzing energy consumption elements for each expected air conditioning methods is used to deduct result of this study.