• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.033 seconds

Mitigation of Methane Emission and Energy Recycling in Animal Agricultural Systems

  • Takahashi, J.;Mwenya, B.;Santoso, B.;Sar, C.;Umetsu, K.;Kishimoto, T.;Nishizaki, K.;Kimura, K.;Hamamoto, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.8
    • /
    • pp.1199-1208
    • /
    • 2005
  • Abatement of greenhouse gas emitted from ruminants and promotion of biogas energy from animal effluent were comprehensively examined in each anaerobic fermentation reactor and animal experiments. Moreover, the energy conversion efficiency of biomass energy to power generation were evaluated with a gas engine generator or proton exchange membrane fuel cell (PEMFC). To mitigate safely rumen methanogenesis with nutritional manipulation the suppressing effects of some strains of lactic acid bacteria and yeast, bacteriocin, $\beta$1-4 galactooligosaccharide, plant extracts (Yucca schidigera and Quillaja saponarea), L-cysteine and/or nitrate on rumen methane emission were compared with antibiotics. For in vitro trials, cumulative methane production was evaluated using the continuous fermented gas qualification system inoculated with the strained rumen fluid from rumen fistulated Holstein cows. For in vivo, four sequential ventilated head cages equipped with a fully automated gas analyzing system were used to examine the manipulating effects of $\beta$1-4 galactooligosaccharide, lactic acid bacteria (Leuconostoc mesenteroides subsp. mesenteroides), yeast (Trichosporon serticeum), nisin and Yucca schidigera and/or nitrate on rumen methanogenesis. Furthermore, biogas energy recycled from animal effluent was evaluated with anaerobic bioreactors. Utilization of recycled energy as fuel for a co-generator and fuel cell was tested in the thermophilic biogas plant system. From the results of in vitro and in vivo trials, nitrate was shown to be a strong methane suppressor, although nitrate per se is hazardous. L-cysteine could remove this risk. $\beta$1-4 galactooligosaccharide, Candida kefyr, nisin, Yucca schidigera and Quillaja saponarea are thought to possibly control methanogenesis in the rumen. It is possible to simulate the available energy recycled through animal effluent from feed energy resources by making total energy balance sheets of the process from feed energy to recycled energy.

Effects of Herbal Plant Mixture(Miracle®) Supplementation on the Productivities of Lactating Sows and Growth Performance and Hematological Characteristics of Piglets (생약제(Miracle® 첨가가 포유모돈의 생산성, 자돈의 성장 및 혈액성상 변화에 미치는 영향)

  • Min, B.J.;Kwon, O.S.;Hong, J.W.;Son, K.S.;Kim, In-Ho
    • Journal of Animal Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.371-378
    • /
    • 2005
  • This study was conducted to evaluate effects of dietary herbal extracts mixturetMiracle" included Angelicae Gigantis Radix, Rehmanniae Radix, Cnidii Rhizoma, Glycyrrhizae Radix, Schizandrae Fructus, Plantago asiatica and Dioscoreae Radix) on the productivities of lactating sowsand growth performance and hematological characteristics of piglets. Twenty seven sows (Yorkshire ${\times}$ Landrace ${\times}$ Duroc, 1 to 3 parities) were used in a 21 day old trial. Dietary treatments included 1) CON (control; basal diet), 2) HPMO.l (basal diet + herbal plant mixture 0.1 %) and 3) HPMO.2 (basal diet + herbal plant mixture 0.2 %). Backfat thickness losses from farrowing to weaning was decreased in HPM treatmentscompared with control(linear effect, P $\leq$ 0.003). ADFI was decreased in sows fed herbal plant mixture(linear effect, P < 0.05). Also, treatments of dietary herbal plant mixture reduced day of return to estrus compared with control(linear effect, P < 0.05). Energy digestibility in HPM treatments were higher than control(linear effect, P $\leq$ 0.05). In piglets, weight gain(P > 0.05) and survivability(P> 0.05) after weaning werenot affected by treatments. No statistical differences were found(P> 0.05) forhematological characteristics in piglets. In conclusion, dietary herbal plant mixture reduces backfat thickness losses and day of return to estrus and improves energy digestibility in lactating sows.

Theoretical Design for the Production of Quinoa (Chenopodium quinoa Willd.) in a Closed Plant Factory

  • Bae, Jong Hyang;Austin, Jirapa;Jeon, Yoon-A;Cha, Mi-Kyung;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.840-844
    • /
    • 2016
  • Quinoa (Chenopodium quinoa Willd.) is a grain crop with high nutritional value. The leaves and sprouts of quinoa can also be consumed either raw or cooked, providing considerably nutritional value as well as high antioxidant and anticancer activities. This study was carried out to obtain basic data to assist in the practical design of a plant factory with artificial lighting for the cultivation of quinoa as a leafy vegetable. We estimated the energy content of the quinoa and the electrical energy required to produce this crop. The yield was 1,000 plants per day, with a planting density and light intensity of $0.015m^2$ ($15{\times}10cm$) and $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. The total number of plants, cultivation area, and electricity consumption were estimated to be 25,000, $375m^2$, and $93,750{\mu}mol{\cdot}s^{-1}$, respectively. White fluorescent lamps were used at a power of 20.4 kW from 1,857 fluorescent lamps (FL, 55 W), and the cost for electricity was approximately 1,820 dollars (exchange rate of $1 = 1,200 won) per month. For a daily harvest of 1,000 plants per day in a closed plant factory, the estimated light installation cost, total installation cost, and total production cost would be 15,473, 46,421, and 55,704 dollars, respectively. The calculated production cost per plant, including labor costs, would be 27 cents for the 25-day cultivation period, with a marketable ratio of 80%. Considering the annual total expenses, income, and depreciation costs, the selling price per plant was estimated to be approximately 56 cents.

Neuro PID Control for Ultra-Compact Binary Power Generation Plant (초소형 바이너리 발전 플랜트를 위한 Neuro PID 제어)

  • Han, Kun-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1495-1504
    • /
    • 2021
  • An ultra-compact binary power generation plant converts thermal energy into electric power using temperature difference between heat source and cooling source. In the actual power generation environment, the characteristic value of the plant changes due to any negative effects such as environmental condition or corrosion of related equipment. If the characteristic value of the plant changes, it may lead to unstable output of the turbine in a conventional PID control system with fixed PID parameters. A Neuro PID control system based on Neural Network adaptively to adjust the PID parameters according to the change in the characteristic value of the plant is proposed in this paper. Discrete-time transfer function models to represent the dynamic characteristics near the operating point of the investigated plant are deduced, and a design strategy of the proposed control system is described. The proposed Neuro PID control system is compared with the conventional PID control system, and its effectiveness is demonstrated through the simulation results.

A Study for Integrated Ocean Energy Utilization System (해양에너지의 복합이용시스템에 관한 기초연구)

  • 김현주;홍석원
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.83-86
    • /
    • 2001
  • This paper aims to make a feasibility study and to propose a master plan for the development of "integrated ocean energy utilization system", which utilizes various renewable ocean energies. Fossils energy, as the most important energy resources which are inevitable for the living and industrial development, becomes exhausted and its consumption creates serious environmental problem. It is important to utilize renewable ocean energy for a sustainable and environmentally friendly development. We survey the integrated utilization of ocean energy based on surveyed energy density distribution and propose concepts of integrated ocean energy utilization plant for both onshore and offshore system. The results of this study can support national effort for renewable energy development utilizing integrated ocean energy and refer as a guideline for the technical development of sustainable integrated ocean energy.

  • PDF

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve (발전용 밸브누설 평가를 위한 다중계측 연구)

  • Lee, S.G.;Park, S.K.;Park, J.H.;Kim, K.H.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

  • PDF

Development of Plant Abnormal Status Response System by Multi-Alarm Pattern in Main Control Room (원자력발전소 주제어실 다중 경보 패턴에 의한 경보/비정상 대응 체계 개발)

  • Choi, Sun Yeong;Jung, Wondea
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.129-135
    • /
    • 2014
  • The number of abnormal operation procedures (AOPs) for mitigating a plant abnormal status amounts to about one hundreds for the most of 1000MWe optimized power plant (OPR1000) and it is expected that the number of AOPs would be increased to cope with an abnormal status occurred newly. However, it is not well organized for operators to select a proper AOP from alarms occurred in main control room (MCR) during a plant abnormal status. It may be a burden to operators since the selection of AOP to respond an abnormal status is authorized by operators. When multiple alarms occur in MCR, it would take more time to respond them than a single alarm. To reduce the efforts, various MCR operation support systems have been developed. The purpose of this study was to develop a multi-alarm pattern card to select an appropriate AOP effectively when multiple alarms occurs in a single upper layout (UL) of MCR. It can be applied for an operation support tool as well as an education tool.

The Design & Analysis of Pulse Separation Device with Thermal Barrier Type for Dual Pulse Rocket Motor (이중펄스 로켓모타의 격막형 펄스분리장치 설계 및 성능평가)

  • Kim, Jinyong;Kwon, Taeha;Lee, Wonbok;Cho, Wonman;Lee, Bangeop;Jung, Gyoodong;Rhee, Youngwoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.93-99
    • /
    • 2015
  • The dual pulse rocket motor(DPRM) distributes the propellant energy effectively via pulse separation device(PSD) to improve the range and terminal velocity of the missile. There are two types of PSD such as bulk head type and thermal barrier type. A subscale thermal barrier type DPRM was designed, manufactured, and tested. The results showed good understanding of the characteristics of the PSD and will be applied to the design of the full scale DPRM.

Power and Efficiency Optimization through Exergy Analysis of Power Plant (발전 플랜트의 엑서지 해석으로부터 발전량 및 발전효율 최적화)

  • Kim, Deok-Jin;Lee, Jae-Byoung;Kang, Su-Hwan
    • Plant Journal
    • /
    • v.9 no.3
    • /
    • pp.43-47
    • /
    • 2013
  • Even if an expert who has majored energy engineering, it is a difficult concept to understand power output optimization and power efficiency optimization. In this study a diagram applying thermodynamic state value as specific exergy and exergy ratio was developed. Although general peoples who did not major energy engineering can be easily understand the concept of power output optimization and power efficiency through the developed diagram. A represented property that can identify the performance of power plant is the main steam temperature and pressure. At the developed diagram the maximum power output line and maximum power efficiency line are shown according to the temperature and pressure of main steam. Therefore we can identify how much a power plant approach to maximum power output and maximum power efficiency.

  • PDF