• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.033 seconds

Study on Feasibility of Integrated Two-Phase Anaerobic Digestion Using Foodwaste Water by Reviewing of Operating Efficiency (일체형 2상 혐기성소화 운전효율 검토를 통한 음폐수 처리 타당성에 관한 연구)

  • Song, Hancheul;Kim, Dongwook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.59-66
    • /
    • 2016
  • The purpose of this study was to review of technical, economical feasibilities regarding Integrated Two-Phase Anaerobic Digestion(ITPAD) method. In order for that, operation conditions and data with 24tpd capacity of operating ITPAD plant were analyzed. The result showed that VS removal efficiency was 73.7% and total amount of biogas was generated $1,239m^3/day$ on the average that represents $54.4m^3/ton$-input of generation efficiency. ITPAD had advantages in terms of required area and energy for heating which were analyzed 15.9%~47%, 11.6%~17.8% lower respectively compared to Conventional Separated Two-Phase Anaerobic Digestion(CSTPAD) method. Thus, it is considered the ITPAD has comparatively high feasibility to be expanded and commercialized to dispose high concentration organic matter of waste such as food waste and its leachate.

Development of Complementary Mild-slope Equation for Stream Function Over Permeable Bed (투수층에 적용 가능한 흐름함수방식의 확장형 완경사방정식의 개발)

  • Kim, Gunwoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.758-765
    • /
    • 2016
  • In this study, wave damping due to a permeable bed of finite depth was modelled using a complementary mild-slope equation for stream function. The energy dissipating term in the mild-slope equation was presented in terms of stream function. In order to prevent re-reflection of reflected waves along the outer boundary, a delta-function-shaped source function was derived to generate a wave in a computational domain. Numerical experiments were conducted to measure the reflection coefficient of waves over a planar slope for various incident wave periods. The numerical result of the proposed model was compared with that of an integral equation method, showing good agreement in general. However, the proposed model showed relatively higher transmission rate for the larger permeability and the longer wavelength.

Policy Initiatives to Establish a National Nuclear Education & Training System (국가 차원의 원자력 교육훈련체계 구축을 위한 정책 구상)

  • Ko, Kyungmin;Park, Min-Cheol;Park, Jae-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.253-265
    • /
    • 2014
  • Nuclear education & training is an important issue for sustainability of nuclear energy and the safety of the nuclear power plant. The purpose of this paper is to present policy initiatives for establishment of the national nuclear education & training system. It analyzed current status of nuclear manpower and nuclear education & training systems of Korean nuclear organizations and government strategic plans for nuclear manpower education & training. The features of the current nuclear education & training in Korea are institutional diversification and decentralization in Industry-University-Research system. However, linkages and cooperation systematically integrated between institutions are very weak. In addition, duplicated education & training programs and resource allocation, and the resultant inefficiency have been raised as a problem. Therefore, this paper proposed the national nuclear education & training system model as a macro policy initiatives and construction of control tower that manage and adjust overall nuclear education & training.

Nutritional Values of Red Pepper Seed Oil Meal and Effects of Its Supplementation on Performances and Physiological Responses of Broiler Chicks

  • An, B.K.;Im, H.J.;Kang, C.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.6
    • /
    • pp.971-975
    • /
    • 2007
  • Two experiments were conducted to evaluate the feeding values of red pepper seed oil meal (RPSOM) and to investigate its dietary supplementation on broiler performances. In Exp. 1, nutritional values of RPSOM were evaluated by analyzing chemical composition and determining true metabolizable energy (TME), nitrogen corrected TME (TMEn) and true available amino acid (TAAA). RPSOM contained 22.50% of CP, 4.75% of ether extract, 27.70% of crude fiber, 4.73% of crude ash and 49.97 ppm of xanthophylls. The contents of capsaicin and dihydrocapsaicin were 34 mg and 31 mg/100 g DM, respectively. The values of TME and TMEn determined by force-feeding 16 roosters were 1.73 kcal/g and 1.63 kcal/g DM, respectively. The average TAAA value of 17 amino acids was 85.22%. In Exp. 2, a total of 225 Ross male broiler chicks, 3 weeks old, were randomly divided into 9 groups of 25 birds each and assigned to three experimental diets containing 0 (control), 5 or 10% RPSOM fed ad libitum for 3 weeks. No significant differences were observed in growth performances and carcass characteristics. The level of serum cholesterol in the 10% RPSOM group was significantly lower than that of the control group (113.92 vs. 137.50 mg/dl). The dietary RPSOM at 5 and 10% levels increased the content of C18:2 ${\omega}{\sigma}$ in leg muscle compared with the control group. The results suggested that RPSOM can be included into broiler feed up to 10% without any negative effects on broiler performances and physiological responses and used as a non-conventional plant protein source, if its nutritional values are well evaluated.

Verification of SPACE Code with MSGTR-PAFS Accident Experiment (증기발생기 전열관 다중파단-피동보조급수냉각계통 사고 실험 기반 안전해석코드 SPACE 검증)

  • Nam, Kyung Ho;Kim, Tae Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.84-91
    • /
    • 2020
  • The Korean nuclear industry developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code and this code adpots two-phase flows, two-fluid, three-field models which are comprised of gas, continuous liquid and droplet fields and has a capability to simulate three-dimensional model. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for accident management plan of nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification work for separate and integral effect experiments is required. In this reason, the goal of this work is to verify calculation capability of SPACE code for multiple failure accident. For this purpose, it was selected the experiment which was conducted to simulate a Multiple Steam Generator Tube Rupture(MSGTR) accident with Passive Auxiliary Feedwater System(PAFS) operation by Korea Atomic Energy Research Institute (KAERI) and focused that the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The MSGR accident has a unique feature of the penetration of the barrier between the Reactor Coolant System (RCS) and the secondary system resulting from multiple failure of steam generator U-tubes. The PAFS is one of the advanced safety features with passive cooling system to replace a conventional active auxiliary feedwater system. This system is passively capable of condensing steam generated in steam generator and feeding the condensed water to the steam generator by gravity. As the results of overall system transient response using SPACE code showed similar trends with the experimental results such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it could be concluded that the SPACE code has sufficient capability to simulate a MSGTR accident.

Low dietary calcium is associated with self-rated depression in middle-aged Korean women

  • Bae, Yun-Jung;Kim, Soon-Kyung
    • Nutrition Research and Practice
    • /
    • v.6 no.6
    • /
    • pp.527-533
    • /
    • 2012
  • It is thought that calcium (Ca) and magnesium (Mg) may be related to mental disorders such as depression; however, there have been few studies investigating the association between Ca and Mg nutrition status with depression in middle-aged female adults. Study subjects in this study included 105 women between the ages of 41 and 57 years. The subjects were divided into three groups according to the Zung Self-rating Depression Scale (SDS) score: Group I (SDS score < 33 percentile; n = 32), Group II (33 percentile ${\leq}$ SDS score < 67 percentile; n = 37), and Group III (67 percentile ${\leq}$ SDS score; n = 36). Anthropometric measurements, dietary intake survey using 3-day dietary records, SDS questionnaire and measurement of serum Ca and Mg were obtained and analyzed. No differences were observed in Ca, plant Ca, and Mg intake among the three groups. However, animal Ca intake by Group III was 141.3 mg, which was significantly lower than 207.6 mg by Group I and 198.3 mg by Group II (P = 0.0345). There were no significant differences in serum levels of Ca, and Mg among the three groups. Correlation analysis indicated that the SDS score had negative correlations with Ca intake (r = -0.2927, P<0.01) and animal Ca (r = -0.3411, P<0.001) after adjusting for age, menopause and energy intake. In conclusion, dietary Ca and animal Ca had negative associations with SDS score among middle-aged Korean female adults. Additional analysis of factors related to the association of calcium and magnesium nutritional status and depression is necessary.

A Case Study on the Application of Systems Engineering to the Development of PHWR Core Management Support System (시스템엔지니어링 기법을 적용한 가압중수로 노심관리 지원시스템 개발 사례)

  • Yeom, Choong Sub;Kim, Jin Il;Song, Young Man
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.9 no.1
    • /
    • pp.33-45
    • /
    • 2013
  • Systems Engineering Approach was applied to the development of operator-support core management system based on the on-site operation experience and document of core management procedures, which is for enhancing operability and safety in PHWR (Pressurized Heavy Water Reactor) operation. The dissertation and definition of the system were given on th basis of investigating and analyzing the core management procedures. Fuel management, detector calibration, safety management, core power distribution monitoring, and integrated data management were defined as main user's requirements. From the requirements, 11 upper functional requirements were extracted by considering the on-site operation experience and investigating documents of core management procedures. Detailed requirements of the system which were produced by analyzing the upper functional requirements were identified by interviewing members who have responsibility of the core management procedures, which were written in SRS (Software Requirement Specification) document by using IEEE 830 template. The system was designed on the basis of the SRS and analysis in terms of nuclear engineering, and then tested by simulation using on-site data as a example. A model of core power monitoring related to the core management was suggested and a standard process for the core management was also suggested. And extraction, analysis, and documentation of the requirements were suggested as a case in terms of systems engineering.

The Study of Optimized Combustion Tuning for Fossil Power Plant (발전보일러의 최적연소조정에 대한 실험적 연구)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.102-108
    • /
    • 2009
  • Fossil power plants firing lower grade coals or equipped with modified system for NOx controls are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. In order to develop a on-line combustion tuning system, field test was conducted at operating power boiler. During the field test the exhaust gases' $O_2$, NOx and CO was monitored by using a spatially distributed monitoring grid located in the boiler's high temperature vestibule and upper convective back-pass region. At these locations, the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. using these monitored information we can improving combustion at every point within the furnace, therefore the boiler can operate at reduced excess $O_2$ and gas temperature deviation, reduced furnace exit gas temperature levels while also reducing localized hot spots, corrosive gas conditions, slag or clinker formation and UBC. Benefits include improving efficiency, reducing NOx emissions, increasing output and maximizing availability. Discussion concerning the reduction of greenhouse gases is prevalent in the world. When taking a practical approach to addressing this problem, the best way and short-term solution to reduce greenhouse gases on coal-fired power plants is to improve efficiency. From this point of view the real time optimized combustion tuning approach is the most effective and implemented with minimal cost.

  • PDF

Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System (공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발)

  • Kim, Bong-Jae;Park, Su-Wan;Kim, Tae-Yeong;Jeon, Dae-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

Optimal Design of Submarine Pipeline for Intake and Discharge of Seawater Desalination Facilities (해수 담수화 설비의 취수 및 배출수 해저 배관 최적화 설계)

  • Choi, Gwangmin;Han, Inseop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.599-609
    • /
    • 2017
  • Desalination plants have been recently constructed in many parts of the world due to water scarcity caused by population growth, industrialization and climate change. Most seawater desalination plants are designed with a submarine pipeline for intake and discharge. Submarine pipelines are installed directly on the bottom of the water body if the bottom is sandy and flat. Intake is located on a low-energy shoreline with minimal exposure to beach erosion, heavy storms, typhoons, tsunamis, or strong underwater currents. Typically, HDPE (High Density Polyethylene) pipes are used in such a configuration. Submarine pipelines cause many problems when they are not properly designed; HDPE pipelines can be floated or exposed to strong currents and wind or tidal action. This study examines the optimal design method for the trench depth of pipeline, analysis of on-bottom stability and dilution of the concentrate based on the desalination plant conducted at the Pacific coast of Peru, Chilca. As a result of this study, the submarine pipeline should be trenched at least below 1.8 m. The same direction of pipeline with the main wind is a key factor to achieve economic stability. The concentrate should be discharged as much as high position to yield high dilution rate.