• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.036 seconds

The Operating Results of the 75kW MCFC Stack (75kW 용융탄산염 연로전지[MCFC] 스택 운전 결과)

  • Kang, Seung-Won;Kim, Beom-Joo;Kim, Do-Hyeong;Lee, Jung-Hyun;Kim, Eui-Hwan;Lim, Hee-Chun
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.3
    • /
    • pp.202-207
    • /
    • 2009
  • A 75kW MCFC stack with the reactive area of 9,600cm$^2$ has been operated and validated in Boryeong thermal power plant. The 75kW MCFC stack was installed at the end of November 28, 2008 and started initial operation on December 23, 2008 after pretreated for about 20 days. At initial load operation, the stack showed the Open Circuit Voltage of 137V, which approaches the theoretical value. At the early stage of rated power operation, the stack displayed the voltage of 104V at the current of 754A and reached the maximum generating power of 78.5kW DC. This stack has been operated for 2,890 hours until April, 2009. In addition, the operation time of rated power records 1890 hours. This Operating result is scheduled to be reflected the design of l25kW stack.

Effects of NOx and SOx on the Medium pH and microalgal growth in photo-culture system (광배양 시스템에서 NOx 및 SOx의 배지 pH와 미세조류 생장에 미치는 영향)

  • Yoon, Se Young;Hong, Min Eui;Sim, Sang Jun
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.3
    • /
    • pp.255-263
    • /
    • 2013
  • Carbon dioxide reduction technologies using photosynthetic microorganism were suggested to overcome environmental destruction caused by $CO_2$ in flue gases from power plant and other industries. However, there are many toxic constituents in flue gas including CO, NOx, SOx. Continuous and Excessive supply of these noxious gases to cells will leads to inhibition of microalgal growth along with partial cell death. In this study, we tested the noxious effect of SOx and NOx on the pH and microalgal growth under photoautotrophic culture in three microalgae of Neochloris oleoabundans, Chlorella vulgaris and Haematococcus pluvialis. As a result, SOx concentration more than 50 ppm led to the rapid reduction of pH, thereby inhibiting of the growth in Neochloris oleoabundans and Chlorella vulgaris. NOx concentration more the 100 ppm reduced the exponential growth of N. oleoabundans and C. vulgaris. And H. pluvialis exhibited low sensitivity to SOx and NOx. Consequently, the three microalgae of N. oleabundas, C. vulagaris and H. pluvialis showed the normal vegetative growth in 25 ppm of NOx and SOx. Above all, H. pluvialis was useful for the $CO_2$ sequestration of the flue gas including high concentrations of NOx and SOx.

Development of Assessment Methodology on Creep-Fatigue Crack Behavior for a Grade 91 Steel Structure (Mod.9Cr-1Mo 강 구조의 크리프-피로 균열 거동 평가법 개발)

  • Lee, Hyeong-Yeon;Lee, Jae-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • In this study, an assessment method on creep-fatigue crack initiation and crack growth for a Mod.9Cr-1Mo steel (ASME Grade 91) structure has been developed with an extension of the French RCC-MR A16 procedure. The current A16 guide provides defect assessment procedure for a creep-fatigue crack initiation and crack growth for an austenitic stainless steel, but no guideline is available yet for a Mod.9Cr-1Mo steel which is now widely being adopted for structural materials of future nuclear reactor system as well as ultra super critical (USC) thermal plant. In the present study an assessment method on creep-fatigue crack initiation and crack growth is provided for the FMS (Ferritic-Martensitic Steel) and assessment on the creep-fatigue crack behavior for a structure has been carried out. The assessment results were compared with the observed images from a structural test.

Damage Analysis for Last-Stage Blade of Low-Pressure Turbine (저압터빈 최종단 블레이드 손상해석)

  • Song, Gee Wook;Choi, Woo Sung;Kim, Wanjae;Jung, Nam Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1153-1157
    • /
    • 2013
  • A steam turbine blade is one of the core parts in a power plant. It transforms steam energy into mechanical energy. It is installed on the rim of a rotor disk. Many failure cases have been reported at the final stage blades of a low-pressure (LP) turbine that is cyclically loaded by centrifugal force because of the repeated startups of the turbine. Therefore, to ensure the safety of an LP steam turbine blade, it is necessary to investigate the fatigue strength and life. In this study, the low cycle fatigue life of an LP steam turbine blade is evaluated based on actual damage analysis. To determine the crack initiation life of the final stage of a steam turbine, Neuber's rule is applied to elastic stresses by the finite element method to calculate the true strain amplitude. It is observed that the expected life and actual number of starts/stops of the blade were well matched.

An Evaluation of Nuclear Design Characteristics of Duplex Burnable Absorber Rods (이중구조 가연성 독봉의 핵설계 특성 평가)

  • 이대진;김명현;송근우;정연호
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.11a
    • /
    • pp.71-79
    • /
    • 2002
  • Nuclear design characteristics of duplex burnable poison rod were evaluated based on 24 month cycle fuel for Korean Standard Nuclear Plant. A fuel assembly with duplex burnable poison rod was designed for an equivalent assembly to 16 gadolinia BPs. Duplex BP is composed of inner region of natural U-12wt%Gd$_2$O$_3$ and outer shell of 4.95wt%UO$_2$-2wt%Er$_2$O$_3$. In order to compare this duplex option, assemblies with 140 erbia pins were designed as an alternative option. The variation of k-infinitive, rod worth, pin peaking and MTC were compared. Duplex BP had the better neutronic performance than gadolinia BP in all parameters. However, Duplex BP was worse than erbia BP in the aspect of safety.

  • PDF

A Study on Operating Characteristics and Design Factors of Floating Photovoltaic Generating Facilities (수상태양광 발전시스템의 운영특성 및 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1532-1539
    • /
    • 2017
  • The floating photovoltaic system is a new concept in the renewable energy technology. That is similar to land based photovoltaic technology except floating system. So the system needs buoyant objects, mooring, ect, besides modules and supports, and that is able to withstand in water level changes and wind strength. Therefore the floating photovoltaic system is much different from land photovoltaic system. K-water (Korea Water Resources Corporation) has been operating two floating photovoltaic system that's capacity is 100 kW and 500 kW respectively since in summer 2011 for commercial generation, and have construction project for 2,000 kW in Boryeong multipurpose Dam and other areas. Furthermore K-water was developing a tracking-type floating photovoltaic system at Daecheong multipurpose Dam and developed and installed an ocean floating photovoltaic demonstration plant at Sihwa Lake in October 2013 for R&D. In this paper, we introduce that structure of floating photovoltaic system include buoyant structure, mooring system and auxiliary device. Especially the rope which is in part of mooring should be always maintain tension under any water level. Also we explain about structure design concept to wind load in an every loading condition and a kind of structure materials and PV structure types used in water environment. Especially ocean floating PV system is affected by tidal current and typhoon. So there are considering the elements in design. Finally we compare with floating and land photovoltaic on power amount. As a result of that we verified the floating photovoltaic system is more about 6.6~14.2 % efficiency than a general land photovoltaic system.

A Study on the Constructions of Fire Events Probabilistic Safety Assessment Model for Nuclear Power Plants (원자력발전소의 화재사건 확률론적안전성평가 모델 구축에 관한 연구)

  • Kang, Dae Il;Kim, Kilyoo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.187-194
    • /
    • 2016
  • A single fire event within a fire area can cause multiple initiating events considered in internal events probabilistic safety assessment (PSA). For an example, a fire event in turbine building fire area can cause a loss of the main feed-water and loss of off-site power initiating events. This fire initiating event could result in special plant responses beyond the scope of the internal events PSA model. One approach to address a fire initiating event is to develop a specific fire event tree. However, the development of a specific fire event tree is difficult since the number of fire event trees may be several hundreds or more. Thus, internal fire events PSA model has been generally constructed by modifications of the pre-developed internal events PSA model. New accident sequence logics not covered in the internal events PSA model are separately developed to incorporate them into the fire PSA model. Recently, many fire PSA models have fire induced initiating event fault trees not shown in an internal event PSA model. Up to now, there has been no analytical comparative study on the constructions of fire events PSA model using internal events PSA model with and without fault trees of initiating events. In this study, the changing process of internal events PSA model to fire events PSA model is analytically presented and discussed.

Changes in Plant Species on a Grass Roof over Time (초지지붕에서의 시간경과에 따른 식생변화)

  • Lee, Young-Moo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.6 s.119
    • /
    • pp.39-53
    • /
    • 2007
  • Unlike conventional roof landscaping, where various kinds of plants and structures are employed, a grass roof is a roof on which herbaceous plants are grown in planting medium and which is not accessed or maintained, mainly because it doesn't have sufficient load capacity to support a regular roof garden. They are mostly built on existing roofs, whether flat slab or gabled. Planting on roofs has numerous advantages, such as creating a biotope, purifying urban air, adding moisture to the atmosphere, storing rain water, preventing flash floods, reducing energy use for heating and air conditioning, enhancing the urban landscape and providing relaxation to the city dwellers, not to mention the alleviation of global warming by absorbing $CO_2$. In addition to the general merits of roof planting, the grass roof has its own unique qualities. Only herbaceous species are planted on the roof, resulting in light weight which allows roofs of existing buildings to be planted without structural reinforcement. The species chosen are mostly short, tough perennials that don't need to be maintained. These conditions provide an ideal situation where massive planting can be done in urban areas where roofs are often the only and definitely the largest space available to be planted. If roofs are planted on a massive scale they can play a significant role in alleviating global warming, heat island effects and energy shortages. Despite the advantages of grass roofs, there are some problems. The most significant problem is the invasion of neighboring plants. They may be brought in with the planting medium, by birds or by wind. These plants have little aesthetic value comparing to the chosen species and are usually taller. Eventually they dominate and prevail over the original species. The intended planting design disappears and the roof comes to look wild. Since the primary value of a grass roof is ecological, a change in attitude towards what constitutes beauty on the roofscape is necessary. Instead of keeping the roof neat through constant maintenance, people must learn that the wild grass with bird's nests on their roof is more beautiful as it is.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Biodegradation of crude oil hydrocarbons by Acinetobacter sp. isolated from activated sludge (활성슬러지에서 단리한 Acinetobacter sp.에 의한 원유탄화수소분해)

  • Dong-Hyuk CHOI;Dong Hoon LEE
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.1
    • /
    • pp.97-108
    • /
    • 2000
  • A Gram-type negative bacteria that can utilize crude oil as the sole source of carbon and energy was isolated from an activated sludge of a local sewage treatment plant and identified tentatively as belonging to the genus Acinetobacter. The isolate could degrade n-alkanes and unidentified hydrocarbons in crude oil and utilize n-alkanes, hydrophobic substrates, as sole carbon and energy sources. n-Alkanes from tridecane (Cl3) to triacontane (C30) in crude oil were degraded simultaneously with no difference in degradation characteristics between the two close odd and even numbered alkanes in carbon numbers. The linear growth of the isolate and the degradation characteristics of Pr-alkanes suggested that the transport of substrates from the oil phase to the site where the substrates undergo the initial oxidation in microorganism might be the rate limiting in the biodegradation process of crude oil constituents. The remainder fraction of substrates after cultivation was considered to reflect the hydrocarbon inclusions in the cell mass, characteristics in Acinetobacter species, and to control the transport of substrates from crude oil phase. On the basis of the results, the isolate was considered to play an important role in the degradation study of hydrophobic environmental pollutants.

  • PDF