• Title/Summary/Keyword: Energy plant

Search Result 3,893, Processing Time 0.027 seconds

Aerodynamic Design and Numerical Study of a Propane-Refrigerant Centrifugal Compressor for LNG Plant (LNG 플랜트용 프로판 냉매 원심압축기의 공력설계 및 전산해석적 연구)

  • Park, Joo-Hoon;Lee, Won-Suk;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Yoon-Pyo;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.781-787
    • /
    • 2011
  • We design a four-stage propane-refrigerant centrifugal compressor for an LNG plant. Using a commercial code, we aerodynamically designed the compressor at each design point of the corresponding stages. We estimated the one-dimensional aerodynamic design output and the three-dimensional shape of the impeller flow passage via three-dimensional flow analysis. In particular, we discuss in detail the flow characteristics of the impeller and the vaneless diffuser passages of the fourth-stage compressor in terms of the velocity fields, the pressure, and the entropy distributions of the flow passages. We include the flow effects of the tip clearance flow, because at this stage the rotating speed and total inlet pressure are higher than those at the other compressor stages are. We carried out performance tests of the designed compressor stages using propane as a refrigerant in the LNG cycle. The practical evaluation could lead to design enhancements in the future.

A Study on the Optimization of Ventilation Fan Position and Flow Rate for a Turbine Building of a Power Plant (화력발전소 터빈 본관의 환풍기 위치 및 용량 최적화에 관한 연구)

  • Kim, T.K.;Ha, J.S.;Park, C.H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.86-93
    • /
    • 2016
  • The existence of high temperature equipment such as steam pipe, deaerator, steam storage tanks and main steam stop valves makes relatively higher workplace temperature in a power plant of the turbine building. In order to cool down the air temperature in the turbine building, the outside air flow with lower temperature passes through the window and the hotter air in the building is extracted to the outside by installing the ventilation fan on the roof. Nevertheless, higher temperature regions near the high temperature equipment still exist in the turbine building and additional fans for the temperature reduction in the higher temperature region should be examined for the optimal location and mass flow rate. The purpose of the present study is to suggest the optimized location and capacity of the additional ventilation fans for a comfortable working environment. From the present study, it has been elucidated that the additional ventilation fans might be located near the high temperature deaerator and it could reduce the mean temperature in the turbine building by $3.0^{\circ}C$ and the temperature near the deaerator could be reduced by $4.2^{\circ}C$.

Research Background and Plan of Enhanced Geothermal System Project for MW Power Generation in Korea (MW급 EGS 지열발전 상용화 기술개발사업의 추진 배경 및 계획)

  • Yoon, Woon-Sang;Song, Yoon-Ho;Lee, Tae-Jong;Kim, Kwang-Yeom;Min, Ki-Bok;Cho, Yong-Hee;Jeon, Jong-Ug
    • Tunnel and Underground Space
    • /
    • v.21 no.1
    • /
    • pp.11-19
    • /
    • 2011
  • Geothermal energy is believed to be an important source among the renewable energy sources to provide the base load electricity. Although there has been a drastic increase in the use of geothermal heat pump in Korea, there is no geothermal power plant in operation in Korea. Fortunately, the first EGS (Enhanced Geothermal System) Project in Korea has started in Dec 2010. This five year project is divided into two stages; two years for exploration and drilling of 3 km depth to confirm the minimum target temperature of 100 degrees, and another three years composed drilling 5 km doublet, hydraulic stimulation of geothermal reservoir with expected temperature of 180 degrees (40 kg/s) and construction of MW geothermal power plant in the surface. This EGS project would be a landmark effort that invited a consortium of industry, research institutes and university with expertises in the fields of geology, hydrogeology, geophysics, geomechanics and plant engineering.

A Study on the Effects of Nuclear Power Plant Structure-Component Interaction in Component Seismic Responses (원전 구조물-기기 상호작용이 기기 지진응답에 미치는 영향 연구)

  • Kwag, Shinyoung;Eem, Seunghyun;Jung, Kwangsub;Jung, Jaewook;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.2
    • /
    • pp.83-91
    • /
    • 2022
  • Seismic design and analysis of nuclear power plant components are performed based on an decoupled model. However, this decoupled analysis has a limitation in that it generates inaccurate results compared to the coupled analysis because it cannot simulate actual phenomena such as the interaction between structures and components. Thus, this study performed seismic coupled and decoupled analysis on an existing nuclear containment structure and related components, considering the mass and natural frequency ratios. And based on these results, comparative analyses of responses of components were conducted. Consequently, the seismic coupled analysis result generally gave a smaller value than the decoupled analysis result. These results were similar to the analysis results for the simple coupled model, which was an existing study, but the difference in component responses was much more pronounced. Also, this was influenced by the installation location of the component rather than the influence of the input frequency of the input seismic motions. Finally, the difference between the decoupled and coupled seismic analysis occurred in the region where the mass ratio of the components was large, and the natural frequencies were almost similar due to the considerable dynamic interaction between the structure and the component in this realm.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

A study on the introduction of organic waste-to-energy incentive system(II): material and energy balance of biogasification (유기성폐자원에너지 인센티브제도 도입방안 연구(II): 바이오가스화 물질·에너지수지)

  • Moon, Hee-Sung;Kwon, Jun-Hwa;Lee, Won-Seok;Lee, Dong-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.77-86
    • /
    • 2021
  • In this study, to use as basic data for the organic waste resource energy incentive system, the energy efficiency is evaluated through the mass balance and energy balance calculation results of the anaerobic digester where food waste, food waste leachate and various organic wastes are treated. As a result of the mass balance analysis for 11 biogasification facilities, it was confirmed that 21.1% of process water and 25.7% of tap water were input in large amounts, excluding organic waste. Accordingly, it accounted for 87.6% of the total effluent of linked treated water. In addition, considering that 15.7% of the total input volume is converted to biogas and the average total solids (TS) is 22%, an average material conversion rate of 75% was confirmed. As a result of the energy balance analysis, the energy conversion rate was confirmed to be 78.5% on average by analyzing the biogas calorific value compared to the potential energy of the influent. The average biogas production efficiency including external energy sources for biogas production was 69.4%, and the biogas plant efficiency to which unused effluent energy was applied was 58.9% on average.

Energy Consumption Analysis of Batch Type Heating Process for Energy Savings in Food Processing Plants (식품가공공장의 에너지 절감을 위한 batch식 가열 공정 에너지 소비 분석 : 사례 연구)

  • Chae-Eun Yeo;Woo-jin Cho;Jae-Hoi Gu;Chae-Young Lim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.817-823
    • /
    • 2023
  • Manufacturing plants face the challenge of reducing energy use in response to climate change. Reducing energy consumption can be seen as one of the most important issues, such as reducing production costs and improving efficiency. Among manufacturing industries, the increase in energy consumption in the food industry is gradually increasing along with the improvement of the standard of living and the increase in population. In order to save energy in food processing plants, it is important to identify and analyze energy consumption characteristics in energy-consuming processes. Prior to this, it is necessary to monitor and analyze existing energy consumption to derive reduction measures. In this study, a small and medium-sized food processing plant producing processed meat products was used as a case study to identify and analyze the energy consumption structure at typical cycle/stage level of the batch heating process. From this, we tried to establish realistic and quantitative goals that can be obtained under individual process operating conditions. The results of this study will be used as basic data for the development of diffusion and pervasive energy saving FEMS technology for common core processes of food factories of small and medium-sized enterprises in the future.

Comparative Analysis of Growth and Antioxidant Enzyme Activities from Two Chrysanthemum Varieties, 'ARTI-purple' and 'ARTI-queen' by Chronic Irradiation of Gamma-ray (감마선 완조사에 따른 국화 'ARTI-purple'과 'ARTI-queen'의 생육 및 항산화 효소 활성 비교 분석)

  • Sung, Sang Yeop;Lee, Yu-Mi;Kim, Sang Hoon;Ha, Bo-Geun;Kang, Si-Yong;Kim, Jin-Baek;Kim, Dong Sub
    • Horticultural Science & Technology
    • /
    • v.31 no.4
    • /
    • pp.490-495
    • /
    • 2013
  • Two chrysanthemum varieties, 'ARTI-purple' and 'ARTI-queen', were chronically irradiated with doses of 30, 50, 70, and 100 Gy for four weeks in gamma-phytotron, a long term irradiation facility. We investigated the growth, responses of antioxidant enzymes (ascorbate peroxidase, APX; catalase, CAT; peroxidase, POD; superoxidase dismutase, SOD) and malondialdehyde (MDA) contents under different doses of chronic-irradiation. The five plant growth measurements including plant height, number of leaves, internode length, stalk diameter and leaf thickness were investigated immediately after four week irradiation. The plant height (p<0.001), internode length (p<0.01), the number of leaves (p<0.001) and stalk diameter (p<0.05) were significantly decreased an increasing doses of gamma-ray. Among them, especially, the internode length was remarkably decreased showing the RD50 (Reduction Dose 50) at approximately 65 Gy. The antioxidant response after four weeks of recovery period, ascorbate peroxidase (APX) (p<0.01), superoxide dismutase (SOD) (p<0.01) and peroxidase (POD) (p<0.001) were significantly increased with an increasing dose of gamma-ray. And malondialdehyde (MDA) (p<0.01) contents showed the significant increase at the 70 and 100 Gy which means the oxidative stress was lasting for a considerable period. In this study, the 50 Gy irradiation as optimal dose showed higher growth than the $RD_{50}$, it also showed insignificant differences on the antioxidant responses and MDA contents. However, the 100 Gy dose showed lower growth than $RD_{50}$.

Load Modeling based on System Identification with Kalman Filtering of Electrical Energy Consumption of Residential Air-Conditioning

  • Patcharaprakiti, Nopporn;Tripak, Kasem;Saelao, Jeerawan
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • This paper is proposed mathematical load modelling based on system identification approach of energy consumption of residential air conditioning. Due to air conditioning is one of the significant equipment which consumes high energy and cause the peak load of power system especially in the summer time. The demand response is one of the solutions to decrease the load consumption and cutting peak load to avoid the reservation of power supply from power plant. In order to operate this solution, mathematical modelling of air conditioning which explains the behaviour is essential tool. The four type of linear model is selected for explanation the behaviour of this system. In order to obtain model, the experimental setup are performed by collecting input and output data every minute of 9,385 BTU/h air-conditioning split type with $25^{\circ}C$ thermostat setting of one sample house. The input data are composed of solar radiation ($W/m^2$) and ambient temperature ($^{\circ}C$). The output data are power and energy consumption of air conditioning. Both data are divided into two groups follow as training data and validation data for getting the exact model. The model is also verified with the other similar type of air condition by feed solar radiation and ambient temperature input data and compare the output energy consumption data. The best model in term of accuracy and model order is output error model with 70.78% accuracy and $17^{th}$ order. The model order reduction technique is used to reduce order of model to seven order for less complexity, then Kalman filtering technique is applied for remove white Gaussian noise for improve accuracy of model to be 72.66%. The obtained model can be also used for electrical load forecasting and designs the optimal size of renewable energy such photovoltaic system for supply the air conditioning.

Past and Present Definitions of the Energy and Protein Requirements of Ruminants

  • Corbett, J.L.;Freer, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.4
    • /
    • pp.609-624
    • /
    • 2003
  • The genesis of methods for defining the nutritional value of feeds and the nutrient requirements of animals, and their development in the late 19th and early 20th centuries in Europe and the USA are outlined. Current energy and protein feeding systems for ruminants are described. Particular reference is made to the Australian systems which are applicable to grazing animals as well as to those given prepared feeds, and enable the effective nutritional management of a imals at pasture by means of the decision support tool GrazFeed. The scheme for predicting intakes by cattle and sheep from pastures allows for the effects of selective grazing on the composition of the feed eaten, and for reduction in herbage intake when a supplementary feed is consumed. For herbage of any given concentration of metabolizable energy (ME) in the feed dry matter the changes with season of year in the net efficiency of use of the ME for growth and fattening and in the yield of microbial crude protein, g/MJ ME, which both vary with latitude, are defined. An equation to predict the energy requirements for maintenance (MEm) of both cattle and sheep includes predictions of the additional energy costs incurred by grazing compared with housed animals and the cost, if any, of cold stress. The equation allows for the change in MEm with feed intake. A flexible procedure predicts the composition of liveweight gain made by any given breed or sex of cattle and sheep at any stage of growth, and the variation with rate of gain. Protein requirements for maintenance, production including wool growth, and reproduction, are related to the quantities of microbial true protein and undegraded dietary protein truly digested in the small intestine.