• Title/Summary/Keyword: Energy plant

Search Result 3,893, Processing Time 0.028 seconds

Estimation of In-plant Source Term Release Behaviors from Fukushima Daiichi Reactor Cores by Forward Method and Comparison with Reverse Method

  • Kim, Tae-Woon;Rhee, Bo-Wook;Song, Jin-Ho;Kim, Sung-Il;Ha, Kwang-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.114-129
    • /
    • 2017
  • Background: The purpose of this paper is to confirm the event timings and the magnitude of fission product aerosol release from the Fukushima accident. Over a few hundreds of technical papers have been published on the environmental impact of Fukushima Daiichi accident since the accident occurred on March 11, 2011. However, most of the research used reverse or inverse method based on the monitoring of activities in the remote places and only few papers attempted to estimate the release of fission products from individual reactor core or from individual spent fuel pool. Severe accident analysis code can be used to estimate the radioactive release from which reactor core and from which radionuclide the peaks in monitoring points can be generated. Materials and Methods: The basic material used for this study are the initial core inventory obtained from the report JAEA-Data/Code 2012-018 and the given accident scenarios provided by Japanese Government or Tokyo Electric Power Company (TEPCO) in official reports. In this research a forward method using severe accident progression code is used as it might be useful for justifying the results of reverse or inverse method or vice versa. Results and Discussion: The release timing and amounts to the environment are estimated for volatile radioactive fission products such as noble gases, cesium, iodine, and tellurium up to 184 hours (about 7.7 days) after earthquake occurs. The in-plant fission product behaviors and release characteristics to environment are estimated using the severe accident progression analysis code, MELCOR, for Fukushima Daiichi accident. These results are compared with other research results which are summarized in UNSCEAR 2013 Report and other technical papers. Also it may provide the physically based arguments for justifying or suspecting the rationale for the scenarios provided in open literature. Conclusion: The estimated results by MELCOR code simulation of this study indicate that the release amount of volatile fission products to environment from Units 1, 2, and 3 cores is well within the range estimated by the reverse or inverse method, which are summarized in UNSCEAR 2013 report. But this does not necessarily mean that these two approaches are consistent.

Analysis of Combining Ability for Quality and Yielding Characteristics in Rapeseed (Brassica napus L.) (유채의 품질과 수량 특성에 대한 조합능력 분석)

  • Shin, Dong-Young;Kwon, Byoung-Sun;Jung, Dong-Soo;Ham, Young-Soo;Lee, Jung-Il;Jang, Young-Seok;Chung, Dong-Hee;Park, Hee-Jin;Bae, Chang-Hyu;Hyun, Kyu-Hwan;Kuk, Yong-In;Choi, Gab-Lim;Yun, Young-Beom
    • Korean Journal of Plant Resources
    • /
    • v.25 no.1
    • /
    • pp.24-30
    • /
    • 2012
  • Naehanyuchae and Youngsanyuchae were originated from the cross between "Erra(female)" and "Tower(male)". The cultivars were made at Bioenergy Crop Research Center, National Institute of crop science, Rural Development Administration, Korea in order to develop the high cold tolerant and yielding rapeseed variety with non-erucic acid and non-glucosinolate as good seed quality indicator. The superiorities of these varieties have been shown through the regional performance trials and demonstration farmers fields. Naehanyuchae and Youngsanyuchae had good agronomic characteristics related to yield potential such as many valuable branches and pods, and long pod length. The seeds of these new varieties composed of the 80% of oleic acid and linoleic acid without erucic acid, and glucosinolate was not extracted in the oil cake. The average grain yields increased by the from 16% to 22% according to the regional performance trials compared to check variety.

Construction and Operation of Small Solar Plant Using Smart-Off-Grid: Case of Tanzania-Korea Innovative Technology and Energy Center (스마트-독립전력망을 사용한 소규모 태양광 발전소의 건설과 운영: 한국-탄자니아 적정기술 거점센터의 사례)

  • Kim, Jisoo;Jung, Woo-Kyun;Ha, Bo-Ra;Moon, Ji-Hyun;Rhee, Herb;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.5 no.2
    • /
    • pp.62-69
    • /
    • 2019
  • Supplying stable electric power is one of the important objectives of the Official Development Assistance (ODA) because it is strongly related with improving living standards and income levels in the region. However, rural areas in many developing countries are not properly connected to national power grids, and even areas connected to national power grids are frequently blacked out due to limitations in power capacity. These lack of electric power is a major obstacle to improving income levels and improving living standards in those areas. The Korea-Tanzania Innovative and Energy Center (iTEC), which was established by Seoul National University in cooperation with the Nelson-Mandela Africa Institute of Science and Technology and Technology (NM-AIST) try to build a small solar power plant using a smart-off grid in rural area of Tanzania, where there is no electricity. 10 kW and 7 kW solar power plants are built in Mkalama Village in Kilimanajaro Region and Ngurdoto Village in Arusha Region to provide power to about 50 households each. In addition, smart monitoring systems were installed to collect data about status of power system and power consumption of each house. iTEC seeks for sustainable improvement the income level and quality of life of rural residents in developing countries through the construction of small solar power plants using smart-off grid, and the implementation of various connected projects.

Analysis of Loss of HVAC for Nuclear Power Plant (원전의 공기조화설비(HVAC) 상실사고 분석방법)

  • Song, Dong-Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.90-94
    • /
    • 2014
  • Environmental qualification (EQ) for safety-related equipment is required to ensure that those equipment will perform their required function even under the harsh environment conditions arising from design basis accident in the nuclear power plant. As a part of EQ program, the room temperature analysis in case of a loss of Heating, Ventilation, and Air Conditioning(HVAC) system was carried out to ensure the operability of the safety-related equipment of a nuclear power plant randomly chosen among the Korean nuclear power plants. In this paper, this analysis was performed in the conservative perspective using GOTHIC code. The room temperature analysis includes selecting the rooms in which the safety related equipment are located but not supported by safety related HVAC and determining the temperature of the selected rooms. Target rooms for the analysis consist of W229/W237 (Aux. feedwater pump room), W232 (Aux. feedwater tank room) and W230 (Equipment passageway). The results showed the temperature range from $43^{\circ}C$ to $83^{\circ}C$, in 72 hours after a loss of HVAC. Those values are far below of generic EQ temperature($171^{\circ}C$). Therefore, it is satisfied with EQ requirement of temperature limits on safety related equipment.

A study on the engineering optimization for the commercial scale coal gasification plant (상용급 석탄가스화플랜트 최적설계에 관한 연구)

  • Kim, Byeong-Hyeon;Min, Jong-Sun;Kim, Jae-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.131.1-131.1
    • /
    • 2010
  • This study was conducted for engineering optimization for the gasification process which is the key factor for success of Taean IGCC gasification plant which has been driven forward under the government support in order to expand to supply new and renewable energy and diminish the burden of the responsibility for the reduction of the green house gas emission. The gasification process consists of coal milling and drying, pressurization and feeding, gasification, quenching and HP syngas cooling, slag removal system, dry flyash removal system, wet scrubbing system, and primary water treatment system. The configuration optimization is essential for the high efficiency and the cost saving. For this purpose, it was designed to have syngas cooler to recover the sensible heat as much as possible from the hot syngas produced from the gasifier which is the dry-feeding and entrained bed slagging type and also applied with the oxygen combustion and the first stage cylindrical upward gas flow. The pressure condition inside of the gasifier is around 40~45Mpg and the temperature condition is up to $1500{\sim}1700^{\circ}C$. It was designed for about 70% out of fly ash to be drained out throughout the quenching water in the bottom part of the gasifier as a type of molten slag flowing down on the membrane wall and finally become a byproduct over the slag removal system. The flyash removal system to capture solid particulates is applied with HPHT ceramic candle filter to stand up against the high pressure and temperature. When it comes to the residual tiny particles after the flyash removal system, wet scurbbing system is applied to finally clean up the solids. The washed-up syngas through the wet scrubber will keep around $130{\sim}135^{\circ}C$, 40~42Mpg and 250 ppmv of hydrochloric acid(HCl) and hydrofluoric acid(HF) at maximum and it is turned over to the gas treatment system for removing toxic gases out of the syngas to comply with the conditions requested from the gas turbine. The result of this study will be utilized to the detailed engineering, procurement and manufacturing of equipments, and construction for the Taean IGCC plant and furthermore it is the baseline technology applicable for the poly-generation such as coal gasification(SNG) and liquefaction(CTL) to reinforce national energy security and create new business models.

  • PDF

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (II) : Based on Piping System Stress Analysis (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (II) : 배관 시스템 응력 해석을 이용한 위험도 평가)

  • Yu, Jong Min;Song, Jung Soo;Jeong, Tae Min;Lok, Vanno;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.14-25
    • /
    • 2018
  • The combined cycle power plant has a cycle of operating the gas turbine with fuel, such as natural gas, and then producing steam using residual heat. The fuel gas is supplied to the gas turbine at a level of 4 to 5 MPa, $200^{\circ}C$ through a compressor and a heat exchanger. In this study, the risk assessment method considering the piping system stress was carried out for safe operation and soundness of the gas fuel supply piping system. The API 580/581 RBI code, which is well known for its risk assessment techniques, is limited to reflect the effect of piping stress on risk. Therefore, the systematic stress of the pipeline is analyzed by using the piping analysis. For the study, the piping system stress analysis was performed using design data of a gas fuel supply piping of a combined cycle power plant. The result of probability of failure evaluated by the API code is compared to the result of stress ratio by piping analysis.

Factors Related to Dietary Fiber Intake Among Sixth Grade Elementary School Children in Daejon City

  • Chung, Young-Jin;Lee, Yangsoon;Suh, Yoon-Suk
    • Nutritional Sciences
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2004
  • This study was conducted to investigate variables related to dietary fiber intake among sixth grade children in an elementary school in Daejon city. One hundred and forty-seven children completed a questionnaire for determining their socioeconomic background and their food habits. Anthropometric measurements were taken, and a 24-hour diet recall method was used to collect three-day food intakes. The socioeconomic status of the children's families belonged to the upper middle class; 53.0% of their fathers and 25.8% of their mothers had completed college or higher degrees. 27.9% of the mothers had jobs, including part-time jobs. Approximately 30% of the children skipped breakfast, 66.4% of the children preferred animal foods to plant foods, and 52.4% of the children preferred green vegetables to yellow or pale vegetables. Grilled meat dishes, such as Grilled beef rib with seasoning, Bulgogi, grilled pork belly and beef steaks, were the most popular types of food eaten outside home by the children. Daily dietary fiber intake was 14.5 g in boys and 14.5 g in girls, and these intakes are low compared to the standard guidelines. The average intakes of energy and protein of the children were 84.5% and 114.0% of the Korean Recommended Dietary Allowances (RDAs), respectively. Besides energy, riboflavin, iron and calcium intakes were below the RDAs, and especially calcium intake was only 50% of the RDAs. On the other hand, thiamin, niacin, ascorbic acid, protein and phosphorus intakes exceeded the Korean RDAs. Family income or the children's body mass index (BMI) was not directly related to dietary fiber intakes. However, higher dietary fiber intakes tended to be related to higher intakes of green vegetables and fruits. Children with higher dietary fiber intake tended to prefer plant foods to animal foods. Energy and most nutrients, except heme iron and retinol, showed positive relationships with dietary fiber intake. Especially potassium and plant origin protein and calcium were highly correlated with dietary fiber intakes(r>0.6). From these results, it is concluded that dietary fiber intakes of these sixth grade elementary school children were less than the standard reference and it is anticipated to decrease further in the future with increased incomes. Therefore, increased intakes of dietary fiber by elementary school children should be promoted through nutrition education, together with the development of cooking methods and recipes utilizing green vegetables and fruits.

Gamma-ray Irradiation on Radio Sensitivity in Cnidium officinale Makino (천궁 돌연변이 유발을 위한 최적 감마선 조사량)

  • Jeong, Jin Tae;Ha, Bo Keun;Han, Jong Won;Lee, Jeong Hoon;Lee, Sang Hoon;Oh, Myeong Won;Park, Chun Geon;Ma, Kyung Ho;Chang, Jae Ki;Kim, Sang Hoon;Kim, Jin Baek;Kang, Si Yong;Ryu, Jai Hyunk
    • Korean Journal of Medicinal Crop Science
    • /
    • v.28 no.5
    • /
    • pp.339-346
    • /
    • 2020
  • Background: Cnidium officinale Makino have been used in traditional medicine in Northeast Asia. Although gamma-ray mutagenesis has been used to develop breeding resources with novel characteristics, research on the radiation sensitivity of C. officinale Makino is limited. Hence, the optimal gamma-ray dosage for mutation breeding in C. officinale Makino was investigated. Methods and Results: Seedstocks were exposed to doses of gamma rays (5 Gy - 50 Gy), and subsequently planted in a greenhouse. After 30 days of sowing, the survival rates and growth decreased rapidly at doses above 20 Gy, while all individuals died at 50 Gy. The median lethal dose (LD50) was 25.65 Gy, and the median reduction doses (RD50) for plant height, number of stems, and fresh weight were 12.81, 9.32, and 23.26 Gy, respectively. Post-irradiation levels of malondialdehyde (MDA), peroxidase (POD), and chlorophyll in the aerial parts of the plant were quantified using spectrophotometry. Relative to the controls, the levels of MDA and POD increased, while the level of chlorophyll decreased at doses ≥ 10 Gy, indicating cellular damage. Conclusions: A dose of 20 Gy was found to be optimal for mutation breeding in C. officinale Makino.

Temperature Reduction with the Location of Window in a Turbine Building of Power Plant (발전소 터빈건물의 창문 위치에 따른 온도저감)

  • Ha, J.S.;Kim, T.K.;Jeong, K.H.
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.207-213
    • /
    • 2016
  • In this study, a thermal flow analysis was performed using the commercial code, ANSYS-FLUENT to reduce room temperature in a turbine building of power plant. The selected control volume of the operating floor and deaerator floor for the turbine building was respectively modelled. The skylight windows at the deaerator floor were employed for ventilation windows. Through the study, in the first we found that all window close of the deaerator floor is one alternative for reducing the temperature of the operating floor. The next thing we knew that for windows open at the front of the deaerator floor, the temperature of deaerator zone and crane zone can be respectively reduced to $1.5^{\circ}C$ and $1.6^{\circ}C$. In addition, for windows close at the rear of the deaerator floor, the temperature of deaerator zone and crane zone can be respectively reduced to 1.4 and $0.5^{\circ}C$. Therefore, it was concluded that a better choice is to open the front windows at deaerator floor to reduce the temperature of the entire deaerator floor having high temperature.

Calculation of non-condensable gases released in a seawater evaporating process (해수 증발과정에서의 기체방출량 계산)

  • Jeong, Kwang-Woon;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.182-190
    • /
    • 2017
  • All liquids contain a small amount of gaseous components and the amount of gases dissolved in a liquid is in accordance with Henry's Law. In a multi-stage thermal-type seawater desalination plant, as the supplied seawater undergoes variations in temperature and pressure in each evaporator, the gases dissolved in the seawater are discharged from the liquid. The discharged gases are carbon dioxide, nitrogen, oxygen, and argon, and these emitted gases are non-condensable. From the viewpoint of convective heat transfer, the evaluation of non-condensable gas released during a vacuum evaporation process is a very important design factor because the non-condensable gases degrade the performance of the cooler. Furthermore, in a thermal-type seawater desalination plant, most evaporators operate under vacuum, which maintained through vacuum system such as a steam ejector or a vacuum pump. Therefore, for the proper design of a vacuum system, estimating the non-condensable gases released from seawater is highly crucial. In the study, non-condensable gases released in a thermal-type seawater desalination plant were calculated quantitatively. The calculation results showed that the NCG releasing rate decreased as the stage comes getting a downstream and it was proportional to the freshwater production rate.