• Title/Summary/Keyword: Energy operator

Search Result 324, Processing Time 0.024 seconds

Instantaneous Amplitude and Frequency Estimator Using the Symmetric Higher Order Differential Energy Operator (대칭구조를 갖는 고차의 미분 에너지함수를 이용한 순간진폭 및 순간주파수 추정기)

  • Iem, Byeong-Gwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1193-1198
    • /
    • 2012
  • An instantaneous amplitude (IA) estimator using the symmetric higher order differential energy operator is proposed. The amplitude estimator and the instantaneous frequency (IF) estimator based on the symmetric higher order differential energy operator coincide with the analyzed signal in time, and they show better estimation results than the IA and IF based on the higher order differential energy operator. Various IF and IA estimators are applied to AM-FM signals for the performance comparison. Among the IF and IA estimators, the IF and IA estimators based on the symmetric higher order energy operator show the best estimation accuracy. Then, the IA and IF estimators are applied to the distorted power line signal to show their usefulness as power disturbance detectors.

Implementation of an Operator Model with Error Mechanisms for Nuclear Power Plant Control Room Operation

  • Suh, Sang-Moon;Cheon, Se-Woo;Lee, Yong-Hee;Lee, Jung-Woon;Park, Young-Taek
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.349-354
    • /
    • 1996
  • SACOM(Simulation Analyser with Cognitive Operator Model) is being developed at Korea Atomic Energy Research Institute to simulate human operator's cognitive characteristics during the emergency situations of nuclear power plans. An operator model with error mechanisms has been developed and combined into SACOM to simulate human operator's cognitive information process based on the Rasmussen's decision ladder model. The operational logic for five different cognitive activities (Agents), operator's attentional control (Controller), short-term memory (Blackboard), and long-term memory (Knowledge Base) have been developed and implemented on blackboard architecture. A trial simulation with a scenario for emergency operation has been performed to verify the operational logic. It was found that the operator model with error mechanisms is suitable for the simulation of operator's cognitive behavior in emergency situation.

  • PDF

AN OPERATOR VALUED FUNCTION SPACE INTEGRAL OF FUNCTIONALS INVOLVING DOUBLE INTEGRALS

  • Kim, Jin-Bong;Ryu, Kun-Sik
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.2
    • /
    • pp.293-303
    • /
    • 1997
  • The existence theorem for the operator valued function space integral has been studied, when the wave function was in $L_1(R)$ class and the potential energy function was represented as a double integra [4]. Johnson and Lapidus established the existence theorem for the operator valued function space integral, when the wave function was in $L_2(R)$ class and the potential energy function was represented as an integral involving a Borel measure [9]. In this paper, we establish the existence theorem for the operator valued function we establish the existence theorem for the operator valued function space integral as an operator from $L_1(R)$ to $L_\infty(R)$ for certain potential energy functions which involve double integrals with some Borel measures.

  • PDF

ROUGH ISOMETRY AND THE SPACE OF BOUNDED ENERGY FINITE SOLUTIONS OF THE SCHRODINGER OPERATOR ON GRAPHS

  • Kim, Seok-Woo;Lee, Yong-Hah;Yoon, Joung-Hahn
    • Communications of the Korean Mathematical Society
    • /
    • v.25 no.4
    • /
    • pp.609-614
    • /
    • 2010
  • We prove that if graphs of bounded degree are roughly isometric to each other, then the spaces of bounded energy finite solutions of the Schr$\ddot{o}$dinger operator on the graphs are isomorphic to each other. This is a direct generalization of the results of Soardi [5] and of Lee [3].

Estimation of Fundamental Frequency Using an Instantaneous Frequency Based on the Symmetric Higher Order Differential Energy Operator (대칭구조를 갖는 일반적인 고차의 미분 에너지함수를 기반한 순간주파수를 이용한 음성의 기본주파수 추정)

  • Iem, Byeong-Gwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2374-2379
    • /
    • 2011
  • The fundamental frequency of the voiced speech is estimated using the instantaneous frequency based on the symmetric higher order differential energy operator. The instantaneous frequency based on the symmetric higher order energy operator shows better frequency estimation result since it is aligned to the time instance of the signal. The speech is pre-processed by a lowpass filter to remove higher frequency components. Then, it is processed by the instantaneous frequency to obtain the fundamental frequency estimates. The symmetric higher order energy operator has been used as an indicator to determine the voiced/unvoiced speech. The fundamental frequency estimates are further processed by a moving average filter to obtain the monotonically changed estimates. The obtained fundamental frequency estimates have been compared with the spectrogram of the speech to confirm its accuracy.

Generalized Higher Order Energy Based Instantaneous Amplitude and Frequency Estimation and Their Applications to Power Disturbance Detection

  • Iem, Byeong-Gwan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.2
    • /
    • pp.162-166
    • /
    • 2012
  • The instantaneous amplitude (IA) based on the higher order differential energy operator is proposed. And its general form for arbitrary order is also proposed. The various definitions of the IA and the instantaneous frequency (IF) estimators are considered. The IA and IF estimators based on the energy operators need less computational cost than the conventional IF and IA estimators exploiting the Hilbert transform. The IF and IA estimators are compared in terms of the frequency and amplitude tracking accuracy of the AM-FM signals. For noiseless case, the IA and IF estimators based on the Teager-Kaiser energy operator show better tracking performance than the IF and IA estimators based on the higher energy operators. However, under noisy condition, the IF and IA estimator based on the higher order energy operators with the order 3 and 4 show better tracking than the Teager-Kaiser energy based estimators. The IF and IA estimators are applied to signals in the various power anomalies to show their usefulness as the disturbance detectors.

A Study on the Multiple Spurious Operation Analysis in Fire Events Probabilistic Safety Assessment of Domestic Nuclear Power Plant (국내 원자력발전소의 화재사건 확률론적안전성평가에서 다중오동작 분석 연구)

  • Kang, Dae Il;Jung, Yong Hun;Choi, Sun Yeong;Hwang, Mee-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • In this study, we conducted a pilot study on the multiple spurious operations (MSO) analysis in the fire probabilistic safety assessment (PSA) of domestic nuclear power plant (NPP) to identify the degree of influence of the operator actions used in the MSO mitigation strategies. The MSO scenario of the domestic reference NPP selected for this study is refueling water tank (RWT) drain down event. It could be caused by spurious operations of the containment spray system (CSS) of the reference NPP. The RWT drain down event can be stopped by the main control room (MCR) operator actions for stopping the operation of CSS pump or closing the CSS motor operated valve if the containment spray actuation signal (CSAS) is spuriously actuated. Outside the MCR, it can be stopped by operator actions for closing the CSS manual valves or motor operated valve or stopping the operation of CSS pump. The quantification result of a fire PSA model that takes into account all recovery actions for the RWT drain down event lead to risk reduction by about 95%, compared with quantification result of fire PSA model without considering them. Among the various operator actions, the recovery action for the spurious CSAS operations and the operator action for the manual valve are identified as the most important operator actions. This study quantitatively showed the extent to which the operator actions used as MSO countermeasures have affected the fire PSA quantification results. In addition, we can see the rank of importance among the operator recovery actions in quantitative terms.

An Applicability of Teager Energy Operator and Energy Separation Algorithm for Waveform Distortion Analysis : Harmonics, Inter-harmonics and Frequency Variation

  • Cho, Soo-Hwan;Hur, Jin;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1210-1216
    • /
    • 2014
  • This paper deals with an application of Teager Energy Operator (TEO) and Energy Separation Algorithm(ESA) to detect and determine various voltage waveform distortions like harmonics, inter-harmonics and frequency variation. Because the TEO and DESA algorithm was initially proposed for speech or communication analysis, its applications are limited to some types of waveform in the power quality analysis area. For example, an undistorted voltage signal is similar with a pure sinusoid. A voltage fluctuation is very similar with an amplitude-modulated signal, from the viewpoint of signal theory. And a continuous frequency variation is similar with a frequency-modulated signal, which is also known as a chirp signal. This paper is written to show that the TEO and DESA algorithm can be used for detecting occurrences of the representative waveform distortions and determining their instantaneous information of amplitude and frequency.

Determination of Power-Quality Disturbances Using Teager Energy Operator and Kalman Filter Algorithms

  • Cho, Soo-Hwan;Kim, Jeong-Uk;Chung, Il-Yop;Han, Jong-Hoon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.1
    • /
    • pp.42-46
    • /
    • 2012
  • With the development of industry, more large-scale non-linear loads are added to existing power systems and they cause the serious power quality (PQ) problems to the nearby sensitive installations more and more. To protect the important loads and mitigate the impact of PQ disturbances on them, various compensating devices are installed. One of the most important control skills used in the compensating equipment at the load side is how fast they can recognize or detect the discontinuous abnormal PQ events from the normal voltage signal. This paper deals with two estimation methods for the fast detection and tracking of general PQ disturbances: Teager Energy Operator (TEO), which is a non-linear operator and used for a short time energy calculation, and Kalman Filter (KF), which is one of the most universally used estimation techniques. And it is also shown how to apply the TEO and the KF to detect the PQ disturbances such as voltage sag, swell, interruption, harmonics and voltage fluctuation.

Analysis of meridian response by bio-energy transmission (생체에너지(기) 전달에 의한 경락 반응 분석)

  • 정석준;이용흠;정동명
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.141-144
    • /
    • 2002
  • Acupuncture effect principle on meridians is what physical stimulation does on general physiology so that it gets into new equilibrium from the fallen function state of human body. However, it is generally accepted that western medicine has regarded the action passageway of various kinds stimulation as nerve fluids tissue or nerve-endocrine-immune system. These regard any action for all meridians as a response to the stimulation. These are not treatments for transmission of the energy. This paper compares the change of electric potential when operator's bio-energy is passed on and when is not. As a result of it, the effect of acupuncture is different when a operator's bio-energy is passed on to meridians and it isn't. Therefore, it means that the general acupuncture is more effective than the insulation one. Moreover, we could certify that there is close relation between an operator's energy transmission and acupuncture effect.

  • PDF