• Title/Summary/Keyword: Energy measurement

Search Result 3,925, Processing Time 0.031 seconds

Comparative Study on Nutrient Intakes, Blood Pressure and Serum Lipid Profile of Korean Adult Men According to Smoking Status (성인 남자의 흡연상태에 따른 영양섭취, 혈압, 혈액 성상 및 지질패턴 비교연구)

  • Choi, Mi-Kyeong;Cho, Hye-Kyung;Sung, Chung-Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.2
    • /
    • pp.164-170
    • /
    • 2006
  • The purpose of this study was to compare the nutrient intakes, blood pressure, and biochemical values and lipid profile in blood according to smoking status. Subjects were recruited from Korean adult men, which included non-smoker (n=47), smoker (n=58), and ex- smoker (n=44) . Anthropometrical measurement, blood pressure measurement, dietary intake assessment using 24-hour recall method, and blood collection and analysis were conducted. The average age, height, weight, and BMI of the subject were 54.7 years, 165.8 cm, 67.3 kg, and $24.5\;kg/m^2 $, respectively. There was no significant difference in general characteristics among three groups. The mean daily intakes of energy and protein were 1740.9 kcal and 69.6 g. The daily folate intake of the smoker was significantly lower than that of the non- smoker or ex-smoker. However, cholesterol intake of the smoker was significantly higher than two groups. The daily total food intake was 1250.0 g for non-smoker, 1180.1 g for smoker, and 1237.5 g for ex-smoker. The mushrooms intake in the smoker was significantly lower than that in the ex - smoker. However, eggs intake of the smoker was significantly higher than two groups. The RBC count and serum GOT/GPT of the subjects were $4598.2\times1000/mm^3$ and 27.3/27.3 U/L. The WBC count, hematocrit and hemoglobin of the smoker were significantly higher than those of the non-smoker and ex-smoker. Blood pressure and serum lipids of the subjects were 128.3/75.5 mmHg for SBP/DBP, 180.2 mg/dL for total cholesterol, 160.8 mg/dL for triglyceride, 41.5 mg/dL for HDL-cholesterol, 106.5 mg/dL for LDL-cholesterol, and 3.5 for atherogenic index. Especially serum triglyceride of smoker was significantly higher than that of non-smoker. The above results revealed that some nutrient intakes, such as folate and cholesterol, and hematological findings, and serum triglyceride of the smoker were different from non-smoker. However, these differences were recovered to non-smoking status by prohibition of smoking. Therefore, in order to stop smoking, the effect of smoking on nutritional and health status should be informed to smoker and more systematic study should be conducted.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

Factors Related to Bone Mineral Content Among Adolescents in Seoul (서울시 일부 청소년의 골질량 관련요인)

  • Shin, Sang-Ah;Hong, Kyung-Eui;Choi, Hyun-Jeong;Roh, Ji-Hyun;Joung, Hyo-Jee
    • Journal of Nutrition and Health
    • /
    • v.41 no.2
    • /
    • pp.156-164
    • /
    • 2008
  • The purpose of this study was to investigate factors related to bone mineral contents (BMC) at os calcis of adolescents. The subjects were 604 students (327 boys and 277 girls) between 7th and 9th grade in Seoul, Korea. The mean age was 14.2 ${\pm}$ 0.9 years. General characteristics were collected by a questionnaire, bone mineral contents (BMC) were measured in os calcis by Duel Energy X-ray Absorptiometry (PIXI, General Electronics, USA) and height and weight were measured by bioelectrical impedance analysis method (Inbody 4.0, Biospace Co. Ltd, Seoul, Korea). Mean BMC of os calsis were 2.241 g. Height (p <.0001), weight (p <.0001I), BMC (p <.0001I) ofboys were higher than those of girls. Percent body fat of girls, however, was higher than that of boys (p <.0001). Anthropometric measurement, pocket money, sibling, experience of fracture, pubertal stage, intake of supplements, physical or outdoors activity, and eating habit had significant influence on BMC of boys. Anthropometric measurement, physical or outdoors activity, and eating habit had significant influence on BMC of girls. Multivariate regression with adjustment for sex and age showed that BMC was associated positively with height, BMI, frequency of regular activity, and intake of spinach or radish leaves (all p <0.05), and negatively with percent body fat (p <.0000 and Korean traditional diet pattern (p = 0.01). On the basis of these results, it is recommended to develop nutrition education and physical activity program for adolescents to improve BMC and prevent osteoporosis.

Negative apparent resistivity in dipole-dipole electrical surveys (쌍극자-쌍극자 전기비저항 탐사에서 나타나는 음의 겉보기 비저항)

  • Jung, Hyun-Key;Min, Dong-Joo;Lee, Hyo-Sun;Oh, Seok-Hoon;Chung, Ho-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.33-40
    • /
    • 2009
  • In field surveys using the dipole-dipole electrical resistivity method, we often encounter negative apparent resistivity. The term 'negative apparent resistivity' refers to apparent resistivity values with the opposite sign to surrounding data in a pseudosection. Because these negative apparent resistivity values have been regarded as measurement errors, we have discarded the negative apparent resistivity data. Some people have even used negative apparent resistivity data in an inversion process, by taking absolute values of the data. Our field experiments lead us to believe that the main cause for negative apparent resistivity is neither measurement errors nor the influence of self potentials. Furthermore, we also believe that it is not caused by the effects of induced polarization. One possible cause for negative apparent resistivity is the subsurface geological structure. In this study, we provide some numerical examples showing that negative apparent resistivity can arise from geological structures. In numerical examples, we simulate field data using a 3D numerical modelling algorithm, and then extract 2D sections. Our numerical experiments demonstrate that the negative apparent resistivity can be caused by geological structures modelled by U-shaped and crescent-shaped conductive models. Negative apparent resistivity usually occurs when potentials increase with distance from the current electrodes. By plotting the voltage-electrode position curves, we could confirm that when the voltage curves intersect each other, negative apparent resistivity appears. These numerical examples suggest that when we observe negative apparent resistivity in field surveys, we should consider the possibility that the negative apparent resistivity has been caused by geological structure.

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

Cesium Radioisotope Measurement Method for Environmental Soil by Ammonium Molybdophosphate (환경토양에서 몰리브도인산 암모늄을 이용한 세슘 동위원소 평가방법)

  • Choe, Yeong-hun;Seo, Yang Gon
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.122-131
    • /
    • 2016
  • Caesium radioisotopes, 134Cs and 137Cs which come from the atmospheric nuclear tests and discharges from nuclear power plants, are very important to study artificial radioactivity. In this work, in order to lower the minimum detection activity (MDA) we investigated environmental radioactivity according to the Environment Measurement Laboratory procedure by 137Cs and 134Cs which is similar to chemical and environmental behaviors of 137Cs. The environmental soils in high mountain areas near nuclear power plant were collected, and an Ammonium Molybdophosphate (AMP) precipitation method, which showed high selectivity toward Cs+ ions, was applied to chemically extract and concentrate Caesium radioisotopes. Radioactivity was estimated by a gamma-ray spectrometry. In gamma energy spectrum, with an increasing of 40K radioactivity, it increased the MDA of 134Cs and 137Cs. Therefore, if the natural radionuclides were removed from the soil samples, the MDA of Caesium may be reduced, and the contents of 137Cs of in the environmental soils can effectively be estimated. In the standard soil sample of Korea Institute of Nuclear Safety, radioactivity of 40K was removed more than 84% on average, and the MDA of 134Cs was reduced 2 times. The content of 137Cs was recovered over 84%. On the other hand, in environmental soils, AMP precipitation method showed removal ratio of 40K up to 180 times, which reduced the MDA about 5 times smaller than those of Direct method. 137Cs recovery ratio showed from 54.54% to 70.06%. When considering the MDA and recovery ratio, AMP precipitation method is effective for detection of Caesium radioisotopes in low concentration.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Long-term and Real-time Monitoring System of the East/Japan Sea

  • Kim, Kuh;Kim, Yun-Bae;Park, Jong-Jin;Nam, Sung-Hyun;Park, Kyung-Ae;Chang, Kyung-Il
    • Ocean Science Journal
    • /
    • v.40 no.1
    • /
    • pp.25-44
    • /
    • 2005
  • Long-term, continuous, and real-time ocean monitoring has been undertaken in order to evaluate various oceanographic phenomena and processes in the East/Japan Sea. Recent technical advances combined with our concerted efforts have allowed us to establish a real-time monitoring system and to accumulate considerable knowledge on what has been taking place in water properties, current systems, and circulation in the East Sea. We have obtained information on volume transport across the Korea Strait through cable voltage measurements and continuous temperature and salinity profile data from ARGO floats placed throughout entire East Sea since 1997. These ARGO float data have been utilized to estimate deep current, inertial kinetic energy, and changes in water mass, especially in the northern East Sea. We have also developed the East Sea Real-time Ocean Buoy (ESROB) in coastal regions and made continual improvements till it has evolved into the most up-to-date and effective monitoring system as a result of remarkable technical progress in data communication systems. Atmospheric and oceanic measurements by ESROB have contributed to the recognition of coastal wind variability, current fluctuations, and internal waves near and off the eastern coast of Korea. Long-tenn current meter moorings have been in operation since 1996 between Ulleungdo and Dokdo to monitor the interbasin deep water exchanges between the Japanese and Ulleung Basins. In addition, remotely sensed satellite data could facilitate the investigation of atmospheric and oceanic surface conditions such as sea surface temperature (SST), sea surface height, near-surface winds, oceanic color, surface roughness, and so on. These satellite data revealed surface frontal structures with a fairly good spatial resolution, seasonal cycle of SST, atmospheric wind forcing, geostrophic current anomalies, and biogeochemical processes associated with physical forcing and processes. Since the East Sea has been recognized as a natural laboratory for global oceanic changes and a clue to abrupt climate change, we aim at constructing a 4-D continuous real-time monitoring system, over a decade at least, using the most advanced techniques to understand a variety of oceanic processes in the East Sea.

A study on the Interior Structure and Scattered Radiation Measurement of Radiotherapy Room (방사선 치료실의 실내 구조와 산란선 측정에 관한 연구)

  • Kim, Min-Ae;Kwon, Yong-Dae;Je, Jae-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.191-195
    • /
    • 2012
  • This research aims at examining the amount of scattered radiation generated during irradiation by adhering structures with different sizes of aluminum prominence and depression to the inside of a radiotherapy room. The irregular aluminum structures were stuck to the wall of a radiotherapy room, and the scattered radiation generated during irradiation was measured. The sizes of the aluminum prominence and depression were $1.5{\times}1.5$, $3{\times}3$, and $5{\times}5\;cm^2$ with the width of 60 cm and the height of 60 cm. The distance between TLD and the wall of the radiotherapy room to measure scattered radiation was 310 cm, and the used radiation energy was 6 MV and 15 MV generated from a linear accelerator. The research result showed that the irradiation amount at 6 MV was 100, and at 300 cGy the scattered radiation decreased by the installation of the structure with aluminum prominence and depression, but at 200 cGy, only the scattered radiation of the uneven structure of $5{\times}5\;cm^2$ decreased. At 15 MV, the irradiation amount was 200 cGy, and at 300 cGy, the scattered radiation was reduced when the rugged aluminum structure was set up, but at 100 cGy, similar result values were produced regardless of the uneven structure. Consequently, installation of an additional structure with aluminum prominence and depression in the present interior structure can decreased the stochastic effect of the scattered radiation generated from the wall of a radiotherapy room and patients.

Synthesis and Characterization of Non-precious Metal Co-PANI-C Catalysts for Polymer Electrolyte Membrane Fuel Cell Cathodes (고분자 전해질 연료전지 캐소드용 코발트-폴리아닐린-탄소로 구성된 비귀금속 촉매의 제조 및 특성 평가)

  • Choi, Jong-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • In order to overcome the cost issue for commercialization of polymer electrolyte membrane fuel cell (PEMFC), this research was conducted for replacing platinum cathode catalyst with non-precious metal catalyst. The non-precious metal catalyst (Co-PANI-C) was synthesized by the simple reduction method with polyaniline (PANI), carbon black, and cobalt precursor without any heat treatment. Characterization of new Co-PANI-C composite catalysts was done by the measurement of X-ray diffraction (XRD) and thermogravimetric analysis (TGA) for structure analysis and performed by rotating disk electrode (RDE) and rotating ring disk electrode (RRDE) for electrochemical analysis. As a result, Co-PANI-C catalyst showed 60 mV lower on-set potential for oxygen reduction reaction (ORR) than Pt/C catalyst, but the overall reduction current of Co-PANI-C catalysts by ORR was still smaller than that of Pt/C. In addition, the ORR behavior of Co-PANI-C catalysts depending on the rotation speed of electrode and the stability of Co-PANI-C catalyst under potential cycling and the performance of fuel cell conditions are also discussed.