• 제목/요약/키워드: Energy measurement

검색결과 3,891건 처리시간 0.033초

Adaptive Data Association for Multi-Target Tracking using Relaxation

  • Lee, Yang-Weon;Hong Jeong
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.267-273
    • /
    • 1998
  • This paper introduces an adaptive algorithm determining the measurement-track association problem in multi-target tracking(MTT). We model the target and measurement relationships with mean field theory and then define a MAP estimate for the optimal association. Based on this model, we introduce an energy function defined over the measurement space, that incorporates the natural constraints for target tracking. To find the minimizer of the energy function, we derived a new adaptive algorithm by introducing the Lagrange multipliers and local dual theory. Through the experiments, we show that this algorithm is stable and works well in general environments. Also the advantages of the new algorithm over other algorithms are discussed.

  • PDF

클린룸과 실험실이 있는 사무용 건물의 에너지 소비 실태 측정 및 분석

  • 김성실;양시선;김영일;김석현
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.966-973
    • /
    • 2001
  • In this study, measurement and analysis of energy consumption of an office building with cleanroom and laboratory have been conducted. Data acquisition system for collecting energy consumption data of the whole building including air-conditioning equipments has been installed in a building located in Seoul. Data are collected for a period of one year in 2000 and analyzed for studying the energy consumption pattern. The percentage of electrical energy used for air-conditioning system is measured to be 46.1%. The collected data will serve as valuable information for diagnosing and improving the energy system of the building.

  • PDF

기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구 (The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment)

  • 김서훈;김종훈;류승환;정학근;송규동
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

감마분광분석을 이용한 226Ra의 직접 측정방법에 대한 적용성 평가 (Feasibility about the Direct Measurement of 226Ra Using the Gamma-Ray Spectrometry)

  • 지영용;정근호;임종명;김창종;장미;강문자;박상태;우주희;구본철;서보균
    • 방사성폐기물학회지
    • /
    • 제12권2호
    • /
    • pp.97-105
    • /
    • 2014
  • HPGe 감마선 검출기를 이용하여 $^{226}Ra$의 방사능을 직접 측정방법의 경우, $^{226}Ra$의 186.21 keV 감마선이 $^{235}U$에서 방출되는 185.7 keV 감마선에 의한 간섭을 받기 때문에 피크면적의 계산에서 반드시 보정이 필요하다. 비록 분해능이 아주 우수한 HPGe 검출기를 사용한다 하더라도 그리고 분광시스템의 채널수를 최대로 늘린다고 할지라도 약 0.5 keV 차이의 두 감마선 피크를 분리해 내기란 현실적으로 어려운 일이다. 본 연구에서는 감마분광분석을 이용한 $^{226}Ra$의 직접 측정방법에 대한 적용성을 평가하기 위하여, 여러 가지 간섭피크 보정들을 이용한 직접 측정방법을 조사하였다. 이를 원료물질 및 공정부산물 시료들에 적용함으로써 직접 측정방법들에서 그 측정 불확도, 직선성 및 적용범위 등을 평가하였다. 최종적으로 방사평형 관계를 이용하여 $^{226}Ra$의 방사능을 측정하는 간접 측정방법으로부터 얻은 $^{214}Pb$$^{214}Bi$의 결과를 직접 측정방법의 결과와 비교함으로써 최적의 측정방법을 유도하였다.

Measurement of Energy Dependent Neutron Capture Cross Section of 99Tc

  • Lee, Sam-Yol;Lee, Sang-Bock;Lee, Jun-Haeng;Lee, Jeung-Min;Yoon, Jung-Ran
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 추계 종합학술대회 논문집
    • /
    • pp.495-500
    • /
    • 2004
  • The neutron capture cross section of $^{99}Tc$ has been measured relative to the $^{10}B$(n,g) standard cross section by the neutron time-of-flight(TOF) method in the energy range of 0.007 eV to 47keV using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.3 eV to 1 keV using the Kyoto University Lead slowing-down Spectrometer(KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(20.01 b) at 0.0253 eV and the KULS measurement to that by the TOF method. The existing experimental data and the evaluated capture cross sections in ENDF/B-VI, JENDL-3.2, and JEF-2.2 have been compared with the current measurements by the linac TOF and the KULS experiments. The energy dependency of the KULS data is close to that of the TOF data which are energy-broadened by the resolution function of the KULS.

  • PDF

A Review on the Job Stress Measurements in Nuclear Power Plant Workers for Human Error Prevention

  • Kim, Seon Soo;Luo, Meiling;Oh, Yeon Ju;Lee, Yong Hee
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.47-58
    • /
    • 2013
  • Objective: The aim of this study is to review the job stress measurement for applying in nuclear power plants(NPPs). Background: The standard and guideline to evaluate and manage the job stress is insufficient in NPPs. Although job stress might have a negative effect on task performance particularly it can be related with human error in NPPs. Method/Results: This paper considered the objective and subjective stress measurements. One of the questionnaire(Korean Occupational Stress Scale) and the experiment method was investigated to apply in NPPs. KOSS was analyzed about the inter item consistency and correlation with the workload, and relative importance. In the objective evaluation considered the experiment method for the physical and mental job stress and analyzed from the phased point of view. Conclusion/Application: The measurement and criteria to evaluate job stress for operators must be complemented on the job characters and environments in NPPs. This study may support to confirm and manage the job stress in NPPs. The study of more specific methodology on job stress in NPPs is required on the basis of this paper.

Measurement of Cloud Velocity and Altitude Using Lidar's Range Detection and Digital Image Correlation

  • Park, Nak-Gyu;Baik, Sung-Hoon;Park, Seung-Kyu;Kim, Dong-Lyul;Kim, Duk-Hyeon;Choi, In-Young
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.605-610
    • /
    • 2014
  • Clouds play an important role in climate change, in the prediction of local weather, and also in aviation safety when instrument assisted flying is unavailable. Presently, various ground-based instruments used for the measurements of the cloud base height or velocity. Lidar techniques are powerful and have many applications in climate studies, including the clouds' temperature measurement, the aerosol particle properties, etc. Otherwise, it is very circumscribed in cloud velocity measurements because there is no Doppler effect if the clouds move in the perpendicular direction to the laser beam path of Doppler lidar. In this paper, we present a method for the measurement of cloud velocity using lidar's range detection and DIC (Digital Image Correlation) system to overcome the disadvantage of Doppler lidar. The lidar system acquires the distance to the cloud, and the cloud images are tracked using the developed fast correlation algorithm of DIC. We acquired the velocities of clouds using the calculated distance and DIC algorithm. The measurement values had a linear distribution.

해상기상관측 시스템 및 실시간 원격 모니터링시스템 개발 (The Development of Offshore Wind Resource Measurement System and Remote Monitoring System)

  • 고석환;장문석;이윤섭
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.72-77
    • /
    • 2011
  • The purpose for installation of offshore weather station is a measurement of wind resources and so on. If weather station is operated, it will be possible to analysis for wind resource and arrangement of wind farm by using measured data. In this paper, we carried out the development of offshore wind resource measurement system for measuring offshore wind resource. Also, In order to monitor for real-time wind data with 1 Hz, we installed the wireless transmission system. All wind characteristic data are sent to the server PC through the this system is connected outport of DataLogger. Transmitted wind data were used in order to look at in the Web-page and tablet PC on a real time basis in a graph. In this paper, we will introduce about the wind resource measurement and remote monitoring system that is the result of study.