• Title/Summary/Keyword: Energy losses

Search Result 707, Processing Time 0.036 seconds

Experimental Study on Heat Losses from Receiver of Solar Thermal Power (태양열발전용 흡수기 설게 및 열손실 특성실험)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Soo;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.672-675
    • /
    • 2007
  • Experimental data are presented which describe heat losses of cavity type receiver in wind tunnel. Experiments are conducted at various conditions such as the heater temperature in cavity changes from 300, 400, and 500 oC, wind speed in tunnel from 2 to 8 m/s, and four different tilt angle of 30, 50, 70, 90o. The power consumption including temperature, voltage and current for each experimental conditions are measured and stored in data logger at everyone second interval. The experimental results show that heat losses increase with increasing wind speed and with tilt angle. However, heat losses for the tilt angle of 70 and 90o is almost same at each heater temperature. In addition, the effects of natural convection in combined convection heat losses vary in according to the tilt angle.

  • PDF

A Study on the Exergy Losses of Steam Power Plant (증기 원동소의 엑서지 손실에 관한 연구)

  • Park, J.C.;Jang, M.S.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.235-243
    • /
    • 1989
  • The purpose of this paper is to obtain enthalpy balance and exergy analysis for the energy losses in a steam power plant. The enthalpy and exergy analysis of the steam power plant were carried out on the various output of steam turbine. While enthalpy analysis shows that circulating loss in the condenser is maximum, exergy evaluation of the power plant shows that the losses of the boiler and turbine are considerably larger than those of condenser and feed water heater. Most irreversible losses of the power plant occur at the boiler. For improving the performance, the precise study about the irreversible losses of the boiler is necessary.

  • PDF

Current Distribution and Numerical Analysis of AC Losses on Multi-Layer HTS Cable (다층 고온 초전도 케이블의 전류 분포 및 교류손실 해석)

  • 김영석;이병성;장현만;곽민환;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.452-455
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-T$_{c}$ superconductors (HTS). A prototype HTS cable have been constructed multi-layer cable using Bi-2223 tape and tested. The AC transport losses under self field were investigated at 77K on the 19 filamentary tape and multi-layer HTS cables. And we carried out numerical analysis using bean model. The result shows that the total transport current of HTS cable in L$N_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to I$^2$ and higher than losses of inner layer. In case of Ip=Ic, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer. As magnetic distribution was concentrated on outer layer.r.

  • PDF

A Study on the Design of the Class E Resonant Rectifier with a Series Capacitor (직력 캐패시터를 가진 E급 공진형 정류기 설계에 관한 연구)

  • 김남호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.343-352
    • /
    • 1998
  • Higher frequency of energy transfer or at least energy conversion has to be used in order to reduce the size of inductors and capacitors required in the power supplies. Conventional PWM switching-mode power supplies have a limitation of operating frequency due to switching losses in the switching transistors and rectifier diodes. Means of reducing switching losses have been developed for high-frequency resonant amplifiers or more exactly dc/ac inverters. Because of smooth current and voltage waveforms resonant convertesrs havelower device switching losses and stresses lower electromagnetic interference(EMI) and lower noise than PWM converters. Therefore in this paper design equations of Classs E resonant low dv/dt rectifier with a series resonant capacitor drived using Fourier series techniques. The theory is compared with simulation results obtained for the rectifier operating at 10[MHz] ac input and 5[V] coutput.

  • PDF

An Improved Zero Voltage Switching Forward DC/DC Converter For Reducing Switching Losses

  • Kim, Eun-Soo;Joe, Kee-Yeon;Park, Hae-Young;Kim, Yoon-Ho;Kim, Choon-Same
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1051-1055
    • /
    • 1998
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

A Gate Drive Circuit for Low Switching Losses and Snubber Energy Recovery

  • Shimizu, Toshihisa;Wada, Keiji
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.259-266
    • /
    • 2009
  • In order to increase the power density of power converters, reduction of the switching losses at high-frequency switching conditions is one of the most important issues. This paper presents a new gate drive circuit that enables the reduction of switching losses in both the Power MOSFET and the IGBT. A distinctive feature of this method is that both the turn-on loss and the turn-off loss are decreased simultaneously without using a conventional ZVS circuit, such as the quasi-resonant adjunctive circuit. Experimental results of the switching loss of both the Power MOSFET and the IGBT are shown. In addition, an energy recovery circuit suitable for use in IGBTs that can be realized by modifying the proposed gate drive circuit is also proposed. The effectiveness of both the proposed circuits was confirmed experimentally by the buck-chopper circuit.

Magnetic Properties of Electrical Steel Material for Electric Machines Core (전기기기 코아용 전기강판 소재의 자기적 특성)

  • 하경호;차상윤;김재관
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.881-883
    • /
    • 2004
  • The high efficiency for motors has been continuously required for energy saving. The iron losses occurring in motor cores account for high percentage in the energy losses of motors, so that electrical steels with lower iron losses have been desired as core materials. It is necessary to understand the basic charecteristic of the electrical steel to design motors and establish manufacturing process for the loss reduction. Therefore, this paper deal with the basic characteristic related with the magnetic properties of electrical steels and descibes the cause of core loss in electrical machines.

  • PDF

Influence of Energy Restriction and Pre-incubation Holding Period of Eggs on Fertility and Hatchability in Aged Broiler Breeders

  • Shyam Sunder, G.;Vijaya Kumar, Ch.;Panda, A.K.;Rama Rao, S.V.;Raju, M.V.L.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.2
    • /
    • pp.240-245
    • /
    • 2010
  • The effects of controlled energy restriction and duration of pre-incubation egg holding on fertility, hatchability and hatch losses were evaluated in aged broiler breeders (64 wk). The energy (ME) required for maintenance, activity, growth and anticipated egg production was calculated and offered to a control group (283-471 kcal/kg) from 21-64 weeks of age. In three other groups, ME was quantitatively reduced either by 20% (SER; severe energy restriction) or 10% (MER; moderate energy restriction) and increased by10% (EEF; excess energy feeding) over the control group (CER; controlled energy restriction). Each diet was offered to 130 pullets in individual cages, and the quantity of ME increased with age. At the end of 64 weeks, fertile eggs were collected from each dietary group for 11 consecutive days and grouped under 4 holding periods based on the length of storage (2, 5, 8 or 11 d). The influence of energy regimes, egg holding intervals and their interaction was evaluated on fertility, hatch losses and hatchability. Broiler breeders maintained on SER regime (231-419 kcal/d) produced maximum number of eggs (993) followed by MER (819), CER (624) and EEF (438) during the 11-day period. The percent fertility and hatchability was significantly (p$\leq$0.05) higher in SER and MER groups compared to CER and EEF. However, energy regimes did not influence the loss in egg weight during pre-incubation storage, shell weight, shell thickness or hatch losses as dead germs and dead in shell. The improvement in hatchability in SER and MER groups appeared to be closely related to higher fertility and lower embryonic mortality. Holding of eggs for 11 days showed a linear loss in egg weight with the length of storage, but did not influence the fertility and hatch losses. The percent hatchability on eggs set was maximum when storage period was restricted to 5 days. The interaction between energy regimes and egg holding periods exhibited better hatchability results with SER regime when eggs were held for 5 days. Response to MER was not different from SER. It was obvious that energy restriction during production period had a positive influence on egg number, fertility and hatchability in aged breeders. At 64 weeks of age, holding of fertile eggs for 5 days prior to incubation was adequate for optimum hatchability in breeders.

Analysis of AC losses in HTS coils by temperature variations

  • Kim, Yungil;Lee, Ji-Kwang;Lee, Seyeon;Kim, Woo-Seok;Lee, Siyoung;Choi, Kyeongdal
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.50-54
    • /
    • 2018
  • We analyzed the temperature dependency of the AC losses in high temperature superconducting (HTS) coils. In the case of a short sample of an HTS tape, the magnetization loss at 4.2 K could be higher than the one at 77 K for a same transport current. It happens when the perpendicular magnetic field is above a certain magnitude. The AC loss characteristics of solenoidal coils have been analyzed at the temperatures of 65 K and 77 K. They were categorized by the aspect ratios. The operating current of a solenoid was normally set about 70 % of the critical current. An HTS solenoid with the same operating current of 77 K causes larger AC losses at 65 K in the most cases of the HTS solenoids. We also analyzed the AC loss characteristics due to the temperature variations for three types of superconducting magnetic energy storages. Two of them were solenoidal types and the other was toroidal type. The results showed the tendency for the coils to have higher AC losses at lower temperature with the same operating currents and scenarios.

Numerical Investigation on Multi-stage Axial Fan and Compressor for Considering Pressure Losses by Instrumentation and Area-averaged Properties (측정장치 압력손실과 면적평균 물리량 보정을 위한 다단 축류 팬과 압축기의 수치해석적 연구)

  • CHOI, JAEHO;KIM, SEMI;LEE, WONSUK;CHOI, TAEWOO;KIM, JINWOOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.401-409
    • /
    • 2018
  • A numerical investigation has been conducted to find the effects of pressure losses by struts and rakes, and averaging methods on the performance of a multi-stage axial fan and a multi-stage axial compressor. Struts and rakes which produce pressure losses are installed upstream of the aerodynamic inlet plane in the fan and the compressor rigs. Some of normal stator vanes are substituted with thick vanes with total pressure probes to measure total pressure between stages. Three-dimensional Reynolds-averaged Navier- Stokes equations with $k-{\omega}$ SST turbulence model were applied to analyze the pressure losses by the struts, inlet rakes, and thick instrumented vanes. The hexahedral grids were used to construct computational domain. Inlet pressure losses were evaluated for the compressor as a function of Mach number. The passage pressure losses due to the instrumented vanes were evaluated at the two speed lines in the fan. Total properties, such as pressure and temperature, were evaluated at the exit of the fan and the compressor with two different averaging methods which are area-averaging and mass-averaging, respectively.